Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
The power supply is Double Insulated and
does not require connection to an Earth
circuit.
The LED units are Safety Extra Low Voltage
and must not be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
This system operates at Safety Extra Low Voltage
(12V), via an LED driver. Never connect the light fittings
directly to the mains without using the supplied driver.
The mains plug must be situated indoors (e.g. house,
garage, shed) in order to protect it from the elements.
Do not exceed the driver load. The supplied driver can
operate up to a maximum of 20 LED heads.
Always disconnect the plug from the mains when
installing or maintaining this system.
This system contains non-replaceable parts and cannot
be serviced. If damage occurs the part should be
scrapped.
This product cannot be dimmed.
The LED heads and driver are rated at IP67. They are
suitable for installation in very wet areas, but must not
be permanently submerged.
The driver must not be installed directly in the soil.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
Specification
The Kit contains:
• 1 x IP67 rated driver with 3 metres of mains cable and mains plug.
• 1 x 5m extension cable
• 2 x 5 LED head looms (total length 7.5m per loom)
• 12 x end plugs
Power Supply: 220-240V 50Hz. Output: 12V DC 15W Max. Constant voltage
Lamp: 73347, 73348, 73349 Ikon Pro CCT 25mm, 35mm, 45mm - Warm white (3000K)/Cool white (4000K)
76615, 76616, 76617 Ikon Pro CCT 25mm, 35mm, 45mm - Daylight white (6500K)/Blue (20000K)
IP rating: 67
Layout
This LED kit has been specifically designed for use in
decking and combines some innovative features to make
installation easier:-
- 2x prewired looms each with 5 LED heads plus a 5m
extension cable allowing longer runs to be achieved.
- The wiring loom can be fitted into the deck during
construction.
- Heads are interchangeable allowing different sizes and
colours to be operated from one power source.
1. Position the plug next to the indoor mains outlet socket
that the system will connect to. Do not plug-in at this
stage.
2. After deciding the layout of the light fittings, ensure
the cables are long enough to connect to the desired
positions. The maximum distance between heads is
1.5m.
3. Drill the mounting holes for the light units taking care
not to damage any pipes or mains cables beneath the
mounting surface. Minimum hole depth is 80mm.
Cutting hole sizes are as follows:-
- 25mm diameter lights = 20mm cutting hole
- 35mm diameter lights = 25mm cutting hole
- 45mm diameter lights = 32mm cutting hole
4. From underneath the decking, feed the connector and
cable up through each installation hole. (A).
5. Fit the protective cap onto the connector - to prevent
the unit from dropping back through the hole and to keep
debris out. (B).
6. Once the decking has been fully assembled and the
lights are ready to be installed, remove the protective cap
and push the LED head unit onto the connector observing
the correct polarity. See CCT Function below. (C)
7. Fit the assembled head units by pushing them into the
holes. The springs on the side of the head will secure the
head units in place. (D)
8. Connect all looms together and connect directly to the
driver output cable, or the extension cable.
9. Ensure any unused heads and cable ends are fitted
with the end plug and protective cap to prevent the
ingress of moisture.
10. Plug the mains plug into the socket and switch on
to test.
Installation
• Planthedesiredlayoutofthesefittingscarefully,
ensuring the cables will reach the distances between
the mains plug, the LED driver and each light fitting.
• Avoidlocatinganycablesinpositionsthatwould
cause a trip hazard. Position cables and driver away
from areas where they may be at risk from being
cut, trapped or damaged.
• Themainsplugmustbesituatedindoors.Thekit
can be wired into an IP67 external terminal block.
(Recommended terminal block ref 61515). This
must be carried out by a competent and qualified
electrician.
• ThedriverandLEDheadunitsareratedatIP67and
can be positioned outdoors.
• Thesefittingsaredesignedtobeusedindecking
and must not be mounted/installed in concrete.
• APIRsensor(71553)andphotocellsensor(71554)
are available to purchase separately for this kit.
AA B C D
• Thesekitsaresuppliedwithremovableand
interchangeable heads. For 73347, 73348 and
73349, it is possible to choose between warm white
(3000K) and cool white (4000K) light output. For
76615, 76616 and 76617, it is possible to choose
between daylight white (6500K) and blue light
(20000K) output.
• TochangecolouryousimplyturntheLEDhead180°
and reinsert back into the loom, according to the
arrows on the connector as detailed below and in
Fig. E.
• 73347/73348/73349
- Arrow on LED head unit is connected to
arrow 1 on connector = Warm white (3000K)
- Arrow on LED head unit is connected to arrow 2
on connector = Cool white (4000K)
• 76615/76616/76617
- Arrow on LED head unit is connected to
arrow 1 on connector = Daylight white (6500K)
- Arrow on LED head unit is connected to arrow 2
on connector = Blue light (20000K).
CCT Function