SCAN 38
INSTRUCTIONS FOR
INSTALLATION AND USE
This manual is accompanied by a
pamphlet with General Instructions
for Installation. Edition 02.04 - GB
Approved according to DIN 18891
Ceramic smoke deflectors
Lift up the ceramic smoke deflector assembly, pull
out the pins in the lateral combustion chamber
plates, and remove the deflectors.
Clean combustion
The SCAN 38 uses the "CB technique" (Clean-
Burn) to ensure an optimally clean combustion.
The extra combustion air is preheated and led into
the combustion chamber close to the ceramic
smoke deflector.
Combustion air
Turn the handle in order to regulate the combus-
tion air. The air is used for combustion and regu-
lates the output of the stove.
You have chosen a product from one of Europe's leading manufactu-
rers of wood-burning stoves. We are convinced that your stove will be
to your full satisfaction and give you many hours of pleasure if you fol-
low the advice and instructions of this manual.
Please read this manual as well as the General Instructions for
Installation before beginning the installation.
Congratulations on your new SCAN stove!
3
4
1
Ceramic smoke
deflectors
Regulation for
cumbustion air
1Ashtray. When you open the door in front of the wood com-
partment, you have access to the ashtray, which is placed
below the combustion chamber. Attention! Be careful when
you empty ashes from the stove. There may be embers left
for up to 24 hours after the stove was last used.
2Lid for ashtray. Under the ashtray you will find a lid to put
on top of the ashtray when you carry it out for emptying.
3Handle for shaking grate. The stove is equipped with a
shaking grate. When you activate the grate handle, the
ashes from the combustion chamber are emptied into the
ashtray.
4 Regulation for primary air. Turn the air valve in order to
open. The primary air is used when lighting and refuelling
the stove. It should always be closed during continuous fir-
ing.
The ashtray, shaking grate, and primary air should always be
closed during continuous firing.
Adjustment of the air
2
SCAN 38
Wood / briquettes Fuel kg/h (beechwood
max. 20% humidity)
SCAN 38 2,3 kg
Combustion air % 75
Primary air % 0
Accessories
For this model you can have the following accessories:
Handle
The handle is elegantly integrated into the
front of the stove. Pull out the handle to
open.
Adjustment screws
The stove has two adjustment screws on
the bottom that can be used for levelling
the stove.
Self-closing door (BA 1)
The door is prepared with a self-closing function
at the factory. If you tighten the spring with the
hexagon spanner, the door will close automati-
cally when you let go of it.
• Soapstone top plate
• Steel floor plate
• Connection piece for fresh-air intake
You should read this manual as well as the General Instructions for Installation before beginning the installation.
SCAN 38
Data for calculation of the chimney
Stove
model
SCAN
Connecting
adaptor
mm
1
Density of
flue gas
flow
g/s
2
Flue gas
tempera-
ture
oC
3
Minimum
draft
Pa
4
Density of
flue gas
flow
g/s
5
Flue gas
temperature
oC
6
Minimum
draft
Pa
7
0,8
Minimum
draft
Pa
38 180 - - - 9 370 12 10
With closed doorsWith open doors
Column 2 and 5 show the flue gas temperature in the connecting adaptor
Column 3 and 6 show the lowest/minimum draft in Pa by rated value
Column 7 shows the lowest/minimum draft in Pa by 0.8 x rated value
Krog Iversen & Co. A/S - DK-5492 Vissenbjerg
1130
900
170
511
187
551
Warranty conditions
All SCAN wood-burning stoves and inserts are made of first-class material and
are subject to a strict quality control before they leave the factory. However, if an
error should occur, we back all SCAN wood-burning stoves and inserts with an
extensive, five-year limited warranty.
See also the General Instructions for Installation delivered with your stove for
more details.
Technical info
Rated output: 7 kW
Min./max.: 3 - 9 kW
Weight: 160 kg
Connection piece, diameter: int. 165 mm / ext. 178 mm
*
**
* To the middle of the rear outlet
** Connection piece to fresh-air intake
Distances to flammable materials
(mm)
Production number
Write the production number of your
stove here so that you have it at hand
in case you need to contact us.
You can choose between several
floor plates in different shapes and
dimensions for your stove. Please
contact your local authorities concer-
ning the security distances needed.
SCAN 38
200
Base plate
Radiation area
200
300
500
800
800

Other SCAN Wood Stove manuals

SCAN Andersen 10 User manual

SCAN

SCAN Andersen 10 User manual

SCAN 67 User guide

SCAN

SCAN 67 User guide

SCAN Andersen 1 User manual

SCAN

SCAN Andersen 1 User manual

SCAN 58-2 User guide

SCAN

SCAN 58-2 User guide

SCAN Scan 83-8 User guide

SCAN

SCAN Scan 83-8 User guide

SCAN 68-2 User guide

SCAN

SCAN 68-2 User guide

SCAN 5-2 User manual

SCAN

SCAN 5-2 User manual

SCAN 22 User manual

SCAN

SCAN 22 User manual

SCAN ANDERSEN 8 User manual

SCAN

SCAN ANDERSEN 8 User manual

SCAN Andersen 4-5 User manual

SCAN

SCAN Andersen 4-5 User manual

SCAN 68-1 User guide

SCAN

SCAN 68-1 User guide

SCAN SCAN 68 Series User guide

SCAN

SCAN SCAN 68 Series User guide

SCAN 41 User guide

SCAN

SCAN 41 User guide

SCAN 1010 Series User guide

SCAN

SCAN 1010 Series User guide

SCAN Andersen 4-5 User manual

SCAN

SCAN Andersen 4-5 User manual

SCAN 53 User guide

SCAN

SCAN 53 User guide

SCAN DSA 8 User manual

SCAN

SCAN DSA 8 User manual

SCAN 60 User manual

SCAN

SCAN 60 User manual

SCAN Andersen 8-2 User manual

SCAN

SCAN Andersen 8-2 User manual

SCAN 65-1 User guide

SCAN

SCAN 65-1 User guide

SCAN 3 User manual

SCAN

SCAN 3 User manual

SCAN 60 User manual

SCAN

SCAN 60 User manual

SCAN 5-2 User manual

SCAN

SCAN 5-2 User manual

SCAN 1004-B User guide

SCAN

SCAN 1004-B User guide

Popular Wood Stove manuals by other brands

Vermont Castings 968 Installation and operating manual

Vermont Castings

Vermont Castings 968 Installation and operating manual

VEVOR WMCPS03 user manual

VEVOR

VEVOR WMCPS03 user manual

Broseley THERMO VERONA DSA Installation and operation instructions

Broseley

Broseley THERMO VERONA DSA Installation and operation instructions

Vermont Castings Seville 1636 Homeowner's installation and operating manual

Vermont Castings

Vermont Castings Seville 1636 Homeowner's installation and operating manual

DutchWest DW1000L02 owner's manual

DutchWest

DutchWest DW1000L02 owner's manual

kozy heat 56150 Installation and operation manual

kozy heat

kozy heat 56150 Installation and operation manual

Lopi Endeavor owner's manual

Lopi

Lopi Endeavor owner's manual

Portway Arundel Wood PCWSB3 Installation and operating instructions

Portway

Portway Arundel Wood PCWSB3 Installation and operating instructions

HASE BARI operating instructions

HASE

HASE BARI operating instructions

RAIS 800 user manual

RAIS

RAIS 800 user manual

Ashley AWC21 Owner's operation and instruction manual

Ashley

Ashley AWC21 Owner's operation and instruction manual

Eureka Jewel Module Operation & installation instructions

Eureka

Eureka Jewel Module Operation & installation instructions

Morsø 7800 installation guide

Morsø

Morsø 7800 installation guide

Drolet Pyropak DB03180 Installation and operation manual

Drolet

Drolet Pyropak DB03180 Installation and operation manual

Dovre 225CB Installation instructions and operating guide

Dovre

Dovre 225CB Installation instructions and operating guide

New Buck Corporation 18 manual

New Buck Corporation

New Buck Corporation 18 manual

Firenzo Viking RU WET manual

Firenzo

Firenzo Viking RU WET manual

IronStrike Grandview GV230GL Installation and operation manual

IronStrike

IronStrike Grandview GV230GL Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.