SCAN 5-2 User manual

SCAN 5-2
INSTRUCTIONS FOR
INSTALLATION AND USE
Tested &
Listed by Beaverton
Oregon USA
OMNI-Test Laboratories,Inc.
Save these instructions
January 2005
KROG IVERSEN & CO. A/S - 5492 VISSENBJERG - DENMARK

2
Table of Contents:
1. INTRODUCTION.................................................................................................................................................................3
CAUTIONS:............................................................................................................................................................4
2. INSTALLATION..................................................................................................................................................................5
Pre Installation Check List:........................................................................................................................................5
The floor ....................................................................................................................................................................6
Ceiling height:............................................................................................................................................................6
Combustible Wall Clearance for top vent installation:..............................................................................................7
Combustible Wall Clearance for rear vent installation:.............................................................................................7
Draft Requirements:...................................................................................................................................................8
Chimney Installation:.................................................................................................................................................8
Factory Built Chimney...............................................................................................................................................8
Masonry Chimney......................................................................................................................................................8
Top vent installation ..................................................................................................................................................9
Chimney connection ................................................................................................................................................10
Rear vent installation: ..............................................................................................................................................11
Chimney height requirements:.................................................................................................................................13
3. INSTRUCTIONS FOR USE...............................................................................................................................................14
Ash Drawer:.............................................................................................................................................................14
Ash Grate:................................................................................................................................................................14
Baffle Plates:............................................................................................................................................................14
Glass: .......................................................................................................................................................................14
Smoke Detectors:.....................................................................................................................................................14
Room Ventilation: ................................................................................................................................................................14
Fire Bricks: ..............................................................................................................................................................14
Ceramic Packing Cord:............................................................................................................................................15
Protected Wall Reduced Clearances:.......................................................................................................................15
Combustion Air Supply: ..........................................................................................................................................15
Draft Requirements:.................................................................................................................................................15
4. OPERATION.......................................................................................................................................................................16
Fueling the Stove:....................................................................................................................................................16
To start a fire:...........................................................................................................................................................16
Refueling: ................................................................................................................................................................17
5. MAINTENANCE................................................................................................................................................................18
Ash Disposal and Removal:.....................................................................................................................................18
Cleaning of Stove: ...................................................................................................................................................18
Replacement part list: ..............................................................................................................................................21
Creosote Formation and the Need for Removal:......................................................................................................21
Door Glass:..............................................................................................................................................................21
6. TROUBLESHOOTING ......................................................................................................................................................22
7. WARRANTY......................................................................................................................................................................23

3
We welcome you as a new owner of a SCAN wood stove. In purchasing a SCAN stove you have
joined the growing ranks of concerned individuals whose selection of energy systems reflects both a
concern for the environment and aesthetics. The SCAN stove is one of the finest home wood stoves in
the world over. This manual will explain the installation, operation and maintenance of the SCAN
stove. Please familiarize yourself with the owner’s manual before operating your stove and save the
manual for future reference. Included are helpful hints and suggestions that will make the operation
and maintenance of your new stove an easier and more enjoyable experience. We offer our continued
support and guidance to help you achieve the maximum benefit and enjoyment from your SCAN
stove.
1. INTRODUCTION
PLEASE READ THIS ENTIRE MANUAL CAREFULLY BEFORE YOU INSTALL AND USE YOUR
NEW SCAN STOVE, FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY
DAMAGE, BODILY INJURY OR LOSS OF LIFE. THIS MANUAL CONTAINS IMPORTANT USER
INFORMATION. KEEP THIS MANUAL WITH THE STOVE AFTER INSTALATION IS COMPLETE.
Safety and environmental testing.
SCAN 5 stoves have been tested by OMNI-Test Laboratories, Inc. of Beaverton, Oregon, and are
safety listed by OMNI to UL 1482, ULC-S627 and EPA certified.
Important information:
No other SCAN stove has the same registration number as yours. The registration number is fixed to
the stove. In case of complaints we request that you have the registration number.
Items included
In the SCAN stove you will find a service box containing the following items:
1 oven mitten
1 handle to operate the shake grate
1 set of fittings for the flue collar
1 set of screws and hexagon spanners
1 bag containing fire starters for the first lightning
2 plastic plugs for covering the transportation holes in the wood compartment.

4
CAUTIONS:
KEEP ASH DRAWER CLOSED DURING FIRING IN THIS STOVE, ASH DRAWER MAY BE
OPENED FOR A MAXIMUM OF 5 MINUTES DURING FIRE STARTUP. USE A METAL CONTAINER
WITH A TIGHT FITTING LID TO DISPOSE OF ASHES.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER
FLUID, OR SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS STOVE. KEEP ALL
SUCH LIQUIDS WELL AWAY FROM THE STOVE WHILE IT IS IN USE.
DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR
ENGINE OIL.
THIS STOVE IS HOT WHILE IN OPERATION, DO NOT TOUCH, KEEP CHILDREN AWAY.
CONTACT MAY CAUSE SKIN BURNS. USE GLOVES WHEN STOKING THE FIRE.
DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE CONNECTED TO ANOTHER STOVE OR
APPLIANCE.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
DO NOT INSTALL IN A MOBILE HOME.
BE SURE TO ALLOW AN ADEQUATE SOURCE OF FRESH AIR INTO THE ROOM WHERE THE
STOVE IS OPERATING (SEE ROOM VENTILATION PAGE 12 AND COMBUSTION AIR SUPPLY
PAGE 13).
DO NOT OPERATE THE STOVE WITHOUT THE FIREBOX BAFFLE PLATES PROPERLY
INSTALLED.
BUILD FIRES DIRECTLY UPON THE HEARTH INSIDE THE STOVE. DO NOT USE GRATES,
IRONS OR ANY OTHER METHOD TO ELEVATE THE FIRE.
THE SCAN STOVES ARE NOT USABLE FOR FIREPLACE INSTALLATION.

5
2. INSTALLATION
PRECAUTION
IF YOUR SCAN STOVE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A
HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW ALL INSTALLATION, OPERATION
AND MAINTENANCE DIRECTIONS. CONTACT YOUR LOCAL BUILDING OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION REQUIREMENTS IN YOUR AREA.
Pre Installation Check List:
Before you begin an installation, review your plans, check to see:
1. Your stove and chimney connector will be far enough from combustible material to meet all
clearance requirements.
2. The floor protection is large enough and is constructed properly to meet all requirements.
3. You have all necessary permits from local authorities. Your local building official is the final
authority for approving your installation as safe and determining that it meets all local and state
building and safety codes.
The metal label permanently attached to the back of every SCAN stove shows that it has been tested
to current UL and ULC safety standards, and gives the name of the testing laboratory. Clearance and
installation information is also printed on the label. Local authorities will generally accept the label as
evidence that, when the stove is installed according to the information on the label and in this manual,
the installation meets codes and can be approved.
Codes vary in different areas. Before starting the installation, review your plans with the local building
authority. Your local dealer can provide any additional information needed.
For any unresolved questions about installation in the USA, refer to the national Fire Protection
Association’s publication ANSI/NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel
Burning Appliances. For installation in Canada, refer to CSA CAN-B365, Installation Code for Solid
Fuel Burning Applications and Equipment. These standards are the basis for many national codes.
They are nationally recognized and are accepted by most local authorities. Your local dealer or your
local building official may have a copy of these regulations.
WARNING: Check all local building and safety codes before installation. The installation instructions
and appropriate code requirements must be followed exactly and without compromise. Alterations to
the stove are not allowed. Do not connect the stove to a chimney system serving another stove,
appliance or any air distribution duct. Failure to follow these instructions will void the manufacturers
warranty.
NOTE: If you plan to vent your stove into an existing masonry chimney, have the chimney inspected
by a local fire marshal or qualified installer. Remember that the chimney and its location on the roof
heavily influent on the stove performance. An oversized flue may not provide effective draught and a
flue liner may be required. (Observe draft requirements). Consult your dealer or qualified installer
before final selection is made.
We advise you to leave enough room to enable cleaning between the stove and the wall.
Other manuals for 5-2
2
Table of contents
Other SCAN Wood Stove manuals
Popular Wood Stove manuals by other brands

RAIS
RAIS attika NEXO 100 GAS installation guide

WoodPro
WoodPro WS-TS-1500 owner's manual

Contura
Contura C 586W installation instructions

Palazzetti
Palazzetti EVA GENERAL INFORMATION - WARNINGS - INSTALLATION - MAINTENANCE

Lopi
Lopi 1250 Republic owner's manual

Panadero
Panadero CAPRI 3V Usage and maintenance instructions