Display Value range Description
CODE: 00000 For special functions
CONTROL: off; on For special functions
6. Input mode
6.1 Reset (to reference/calibration + offset value)
Precondition: Parameter 'Reset enable' (RESET:)
in programming mode must be programmed to
"on", "del.1s" or "del.3s" but unit must not be
left in programming mode (see chapter 4 'To leave
programming mode').
For "Modulo" display mode
Press key to set the display to reference/ca-
libration + offset value.
For "0-90-0" display mode
Press key to set the display to reference/ca-
libration value.
6.2 Incremental measurement
not 0-90-0 display mode!
Precondition: Menu point 'Incremental measure-
ment enable' (ABS/REL:) in programming mode
must be programmed to "on", but unit must not
be left in programming mode (see chapter 4 'To
leave programming mode').
Switching on by pressing the key.
The display is zeroed and an "R" is displayed
on position 1.
Switchin off by pressing the key once more. The
absolute measuring value is displayed again.
While in the incremental measurement mode the
display can also be set to zero by pressing key
. This does not change the absolute measurement
in the background.
6.3 Direct alteration of reference/ offset value
or calibration/ offset value, resp.
Precondition: In programming mode menu point
'Reference/offset value input enable' (RE/OF.EN:) or
'calibration/offset value input enable' (CA/OF.EN:)
in display mode 'modulo', resp. reference/calibra-
tion value input enable (RE.EN:/CA.EN:) in display
mode '0-90-0' must be programmed to "on", but
unit must not be left in programming mode (see
chapter 3 'To leave programming mode').
Input reference/calibration value
Change of reference/calibration value is enabled
by pressing the key, with subsequent pressing
of the key (within 1 sec.).
•
•
•
•
•
•
•
The display then shows the reference/calibration
value, which can be changed via the two arrow
keys. By pressing the key, the value is saved
and directly taken over in the display.
Input offset value not for '0-90-0'!
Change of offset value is enabled by pressing the
key once again. The display then shows the
offset value, which can be changed via the two
arrow keys. By pressing the key, the value is
saved and directly taken over in the display.
Finishing direct input of reference/calibrati-
on/offset value
If no key has been pressed for approx. 30s or if
you press again key , MA10/4 will return to
display mode.
6.4 Direct input of limiting value (only for
sqitching output option)
If the limiting values must be chanded frequently
in the application, there is the possibility to
directly call up the input of limiting values in
the input mode.
Precondition: In programming mode menu point
Enabling of modification of the limiting value (LI-
MIT.EN:) must be programmed to "on", but unit
must not be left in programming mode (see chap-
ter 4 'To leave programming mode').
Change of the limit values is enabled by pressing
the key, with subsequent pressing of the
key (within 1 sec.).
The display then shows the upper limit value, which
can be changed via the two arrow keys. By pressing
the key, the changed value is saved.
After pressing key once again, the display
shows the lower limit value, which also can be
changed via the two arrow keys. By pressing the
key, the changed value is saved.
If no key has been pressed for approx. 30s or if
you press again key , MA10/4 will return to
display mode.
7. 0-90-0 Angle display
If the encoder value is smaller than 90 (or 90.0 or
90.00, resp.), it is immediately displayed. Howe-
ver, if it exceeds the above limits, it is calculated
according to the following formula:
Displayed value = 180-encoder value
•
•
•
•
•
•
•
•