Medfusion® Model 3500 pump V6 Operator’s Manual
iii
Table of Contents
Important Safety Information 1
Warnings.....................................................................................1
Cautions......................................................................................4
Symbols.......................................................................................5
Introduction 6
Indications for use.....................................................................6
Contraindications......................................................................7
About the pump 8
Features and Controls...............................................................8
Keypad closeup ....................................................................9
Pump Customization and General
Programming 11
Custom Conguration........................................................... 11
General Programming........................................................... 13
Exceeding limits...................................................................... 13
How pump settings and limits are prioritized.................... 13
User dened pump Congurations ..................................... 14
What are Congurations?................................................ 14
When are Drug Programs used?..................................... 14
Who can use these Drug Programs?.............................. 14
Types of programmable Library Categories.................. 14
Using a Custom Conguration............................................. 15
Using Quick Libraries............................................................ 16
PharmGuard® Safety Soware: Dose Protocol
Protection..................................................................... 18
So limits........................................................................... 18
Hard limits......................................................................... 18
Adjusted limits in reverse............................................ 19
Overridden limits in reverse....................................... 19
Invalid infusion parameter combination .................. 19
PharmGuard® Supported Syringes (PSS) Series 2.............. 20
Navigating the pump menus................................................. 21
e Workow Process...................................................... 21
Guidelines for enhanced pump performance 23
Always use the smallest syringe for volume of uid
being delivered ............................................................ 23
Bolus Volume .......................................................................... 24
Use appropriate internal diameter tubing ........................... 24
Programming an Infusion 25
Turn the pump on .................................................................. 25
Turning the pump o....................................................... 26
Selecting a Delivery Mode and Programming an
infusion ........................................................................ 27
General Infusion Programming Procedure .................. 28
Selecting an Infusion.............................................................. 29
Select a Prole (Custom Conguration) ....................... 30
Select a Category .......................................................... 31
Select a Drug Program ................................................ 31
Select a Delivery Mode (Medfusion® Standard
Conguration).............................................................. 32
Loading a syringe and syringe model setup........................ 33
Unloading the syringe ................................................. 37
Programming Infusions......................................................... 38
Continuous mode: mL/hr............................................... 38
Dose / Min and Dose / Hr............................................... 39
Dose / Day ......................................................................... 41
Dose / Time ....................................................................... 43
Body weight/surface area infusion deliveries ............... 45
Volume / weight infusions............................................... 47
Dose/kg/time (dose/m2/time)......................................... 49
Volume / weight / time..................................................... 51
Volume / time.................................................................... 53
Intermittent volume / time ............................................. 54
Recall last settings............................................................. 56
Priming the system................................................................. 58
Options 60
Bolus dosing............................................................................ 61
Bolus programming.......................................................... 61
Bolus delivery.................................................................... 63
Continuing an interrupted bolus dose ...................... 64
Bolus dose rate reduction ................................................ 65
Loading doses ......................................................................... 67
Set up loading dose........................................................... 67
Delivering a loading dose ................................................ 69
Continuing an interrupted loading dose .................. 70
Loading dose rate reduction............................................ 71
Volume limit ........................................................................... 73
Setting volume limit ........................................................ 73
Keep Vein Open (KVO) rate................................................. 75
Programming KVO rate .................................................. 75
Standby .................................................................................... 77
Programming standby...................................................... 77
Delayed start ........................................................................... 79
Programming delayed start............................................. 79
Periodic callback alarm ......................................................... 80
Programming periodic callback alarm .......................... 80
Override and toggle features................................................. 82
Change to Dose / Change to Volume ............................ 82
Override occlusion limit ................................................. 83
Override alarm loudness ................................................. 84
Disable/enable FlowSentry™ pressure monitoring ....... 85
Disable/enable near empty alarm tone .......................... 85
Disable/enable vol empty alarm tone............................. 86
Infusion Delivery 87
Starting & stopping infusion delivery.................................. 87
Start delivery from pause................................................. 87
Starting delivery from standby or delayed start............ 88
Stopping delivery.......................................................... 88
Continuing interrupted delivery................................ 88
Flush feature............................................................................ 89
Volume only ...................................................................... 89
Continuing an interrupted ush infusion................. 90
Volume and time............................................................... 91
Time to occlusion ................................................................... 93
Occlusion trend graph during delivery ............................... 93
FlowSentry™ pressure monitoring (rapid occlusion
detection) ...................................................................... 93
Post occlusion bolus reduction ...................................... 94
Making changes during delivery .......................................... 95
Changing delivery rate..................................................... 95