1-8 (E) BVE-700A
LEDs
Ref. No. Adress Name Function Normal state
D900 to (H-6) _7SEG LED 00
D915 Error status indication.
Normal: Displays 00.
When an error occurs: Displays an error code.
(See Maintenance Manual for details.)
D930 (H-4) SW_ACT Status indication of SWER on the rear panel. Lights up
Lights up in green when the SWER communication
system can be operated correctly at startup.
D931 (H-4) MIX_ACT Status indication of MIXER on the rear panel. Lights up
Lights up in green when the MIXER communication
system can be operated correctly at startup.
D932 (H-4) P1_ACT Status indication of PLAYER-1 on the rear panel. Lights up
Lights up in green when the PLAYER-1 communica-
tion system can be operated correctly at startup.
D933 (H-4) P2_ACT Status indication of PLAYER-2 on the rear panel. Lights up
Lights up in green when the PLAYER-2 communica-
tion system can be operated correctly at startup.
D934 (H-4) P3_ACT Status indication of PLAYER-3 on the rear panel. Lights up
Lights up in green when the PLAYER-3 communica-
tion system can be operated correctly at startup.
D935 (H-3) REC_ACT Status indication of RECORDER on the rear panel. Lights up
Lights up in green when the RECORDER communica-
tion system can be operated correctly at startup.
D936 (H-3) PNL_ACT Status indication of PANEL on the rear panel. Lights up
Lights up in green when the PANEL communication
system can be operated correctly at startup.
D937 (H-3) EDL_ACT Status indication of EDL on the rear panel. Lights off
Lights up in green when sending data.
D940 (H-4) 3.3 V 3.3 V power supply status indication. Lights up
Lights up in green when 3.3 V power is supplied.
Lights off at error.
D941 (H-4) 5 V 5 V power supply status indication. Lights up
Lights up in green when 5 V power is supplied.
Lights off at error.
D942 (H-4) 12 V 12 V power supply status indication. Lights up
Lights up in green when 12 V power is supplied.
Lights off at error.
D1000 (H-4) REF_EXT Lights up in green when a signal is input to REF Lights up
VIDEO IN on the rear panel and is correctly
recognized.
D1001 (H-4) PLL_LOCK Lights up in green when the reference signal is Lights up
locked.
D1500 (H-3) ETHER_100 Lights up in green when the mode of NETWORK Lights off
is set to 100 Mbps base.
D1502 (H-3) ETHER_ACT Lights up in green when communication is Lights off
established through NETWORK on the rear (when network is not
panel. connected)
D1700 (H-5) TEMP Blinks in green when the temperature in Lights off
the BVE-700A turns 85 °C or higher.
At the same time, TEMP ERROR is displayed
on the scratchpad on the control panel.
D1702 (H-4) FAN Lights up in green when the temperature in Lights off
FAST the BVE-700A turns 45 °C or higher.