Base Only
October 2018
1165580001 Rev A
Page 3 of 32
RISK OF SERIOUS INJURY:
POTENTIAL FOR INJURY: The use of worksurfaces that do not comply with the Steelcase deÀned criteria and limitations could cause personal injury or property damage due to pinch points, instability, or other
problems.
POTENTIAL FOR NON-COMPLIANCE: The use of work surfaces that do not comply with Steelcase criteria VOIDS any Steelcase claims of compliance with ANSI/BIFMA, UL, LEED, or other applicable require-
ments. The use of non-Steelcase work surfaces on Steelcase adjustable-height bases may NOT be accepted as compliant to municipal electrical codes or OSHA federal workplace standards, because this use does
not create an NRTL (UL, ETL, etc.) listed product. Steelcase is not responsible for the ultimate determinations of compliance for height-adjustable bases with non-Steelcase work surfaces. Steelcase assumes NO
liability for lack of standards compliance in these instances.
WARRANTY RESTRICTIONS: The use of non-Steelcase supplied work surfaces VOIDS all Steelcase warranties, expressed or implied.
DISCLAIMER: The use of non-Steelcase work surfaces is NOT recommended. Any use of a non-Steelcase work surface requires additional investigation by the customer regarding the appropriateness for use. It is
the sole responsibility of the customer to determine the suitability and safety of the selected work surface construction and attachment means. The following information is provided as a guideline, but does not ad-
dress all potential issues. Customers should seek professional guidance as to the appropriateness of their chosen work surface.
MANDATORY REQUIREMENTS REGARDLESS OF WORK SURFACE MATERIAL OR CONSTRUCTION:
FASTENERS: Adjustable-height bases include fasteners intended for use with Steelcase work surfaces.
These fasteners may potentially also be suitable for work surfaces meeting the following criteria:
• Medium-density or higher particleboard or Àberboard cores with High-pressure laminate (HPL), Low-
pressure laminate (LPL) or veneer & backers
• Thickness of .984” (25.0 mm) or greater
•Fasteners located a minimum distance of .984” (25.0 mm) from any edge
Any other work surface construction will require different and/or additional fastening means and these means
must be determined by the project’s designer, architect, or engineer. For example, solid-surface materials
should use appropriate threaded inserts and corresponding fasteners or similar attachment means.
In all cases, all fastener locations provided in the base attachment features MUST be used (e.g. if attachment
cantilever has 6 screw holes, all 6 holes must be used for attachment).
DIMENSIONAL LIMITATIONS:
• Work surface depth not to exceed 875mm
• Maximum work surface width may not exceed 2050mm
FOLLOW ALL WARNINGS PROVIDED FOR BASE + WORK SURFACE.
WORKSURFACE
WIDTH
WORKSURFACE
DEPTH
WARNING