TFB-1166
Analog Addressable Manual Call Point,
Resettable, Short Circuit Isolator
Installation and User Manual
Issue Date: 28/09/2017 Rev:01
IMPORTANT WARNINGS
GENERAL
✓Before using the device read this manual carefully. Keep it
just in case of necessity.
✓Abide all the rules and precautions stated in the manual.
Follow all the instructions one by one.
✓Keep the devices away from water and moisture.
CONDITIONS
Do not energize the device above or below the given limits of
extreme hot or cold conditions.
Temperature: -10C ile +60C arası
Relative Moisture: +40°C’de ≤93%
SERVICE
Do not try to fix the device on your own. Removal of cover
may end up with electricity shock.
In case of any defect or malfunction, contact with your dealer
or with authorized service. All the technical interventions
have to be done by technicians of company.
MALFUNCTIONS THAT REQUIRE TECHNICAL SERVICE
In case of any malfunction or below conditions contact with
your authorized service,
✓When Mains cable or the plug is harmed,
✓Contact of device with a fluid,
✓Exposure of rain and water,
✓Fell down of device or harmed outer cover,
✓Serious performance fall on the device,
✓Depending on the instructions stated in manual, if your
device not working properly, further usage or possible wrong
usage may cause other malfunctions. Contact with your
authorized service in such terms.
MAINTENANCE ON YOUR OWN
Do not try to fix the device on your own. Removal of cover
may end up with electricity shock.
In case of any defect or malfunction, contact with your dealer
or with authorized service. All the technical interventions
have to be done by technicians of company. Device must be
cleaned up with a dry fabric. No-chemicals are allowed for
cleaning
TRANSPORTATION
Device must be carefully transported avoiding all physical
bump, stroke and possible fluid entry. Malfunctions that
caused by improper transportation is not under warranty.
HUMAN AND NATURE CONDITION
This device contains no chemical or biological elements that
could harm human condition
CE
1922
Bilgi Elektronik San. ve Tic. A.Ş.
Dudullu OSB 1. Cad. İsmet Tarman İş Merkezi
No:1 Kat:2 No:32 Ümraniye / İstanbul
17
1922-CPR-0898
EN 54-11:2001, EN 54-11:2001/A1:2005,
Manual call points,
EN 54-17:2005,
Short-circuit isolators
TFB-1166
Technical data: See BİLGİ-TEC-170907-2 held by the
manufacturer.
MOUNTING AND CONNECTION
1. Mount the wall of the manual call base so that the fire
cords pass through the rear hole. Do not tighten the wall
mounting screws too much.
2. The terminals on the electronic card in the Manual Call
Point is LIN +, GNG, EARTH, GND and LOUT + . For
trouble-free operation, the addressable panel must be
connected to the GND terminal next to the + LIN +, - pin
of the cable from the circuit board. For other loop
devices, it should go out from the GND and LOUT +
terminals.
3. The incoming and outgoing EARTH cable to the
addressable button via the loop cable must be connected
to the EARTH terminal on the manual call point button to
provide the earth integrity of the loop line devices.
4. After the TFB-1165 addressable manual call button is
connected to the panel and the LED on it is flashing to
indicate that it is communicating, it blinks blue at intervals
of 20 seconds. In case of LED alarm continuously RED
light. If a short circuit occurs on the loop circuit, the
YELLOW LED on the circuit breaker is lit continuously
and the short circuit point is opened by two isolators to
protect the loop circuit.
TEST
SPECIFICATION
Model
Nominal
Operating
Voltage
Besleme
Gerilimi
Normal operating
current / Alarm
current
Suitable
Cable
Thickness
Suitable
Operating
Temperature
(°C),
Moisture
Type of
Breakable
Feature, Usage
Area
Body Material,
Dimensions,
Weight
TFB- 1166
24 VDC
15-32 VDC
1,5mA. / 6mA.
Between
0,4mm to
2.0mm
-10 ~ +60
≤93% @ +40°C
A ,
Closed area
Surface Mount
RED ABS
86x55x88mm
145 gr
MANUFACTURER
* 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see: www.recyclethis.info.
Bilgi Elektronik San. ve Tic. A.Ş.
Dudullu Organize Sanayi Bölgesi 1. Cadde İsmet Tarman İş Merkezi
No:1 Kat:2 No:32 Ümraniye / İstanbul
Telephone: +90 216 455 88 46 Fax: +90 216 455 99 06
Sales: sales@bilgielektronik.com.tr Technical Support: support@bilgielektronik.com.tr
3 ) The key from inside the box is
inserted and is pushed upwards
and observed to be the first
condition. In this case the LED on
it starts blinking with blue light at
intervals of 20 seconds
2 ) Alarm condition observed on
the Manual Call Point.
1 ) In the first case press in the
middle point of Manual call point..
Warning:The product only works with TFP-121x, TFP-122x and TFP-123x
Analogue Addressable Fire Alarm panels.
Ürün sadece Teknim TFP-12XX Analog Adresli Yangın
Alarm Panelleriyle birlikte çalışır.

Other Teknim Security System manuals

Teknim PARS Series User manual

Teknim

Teknim PARS Series User manual

Teknim TFB-3165 Series User manual

Teknim

Teknim TFB-3165 Series User manual

Teknim VAP416 User manual

Teknim

Teknim VAP416 User manual

Teknim PARS Series User manual

Teknim

Teknim PARS Series User manual

Teknim TFM-1190 User manual

Teknim

Teknim TFM-1190 User manual

Teknim TFS-1193R User manual

Teknim

Teknim TFS-1193R User manual

Teknim VAS 740 F User manual

Teknim

Teknim VAS 740 F User manual

Teknim TFB-3165 User manual

Teknim

Teknim TFB-3165 User manual

Teknim PARS Series Assembly instructions

Teknim

Teknim PARS Series Assembly instructions

Teknim TFP-40 Series User manual

Teknim

Teknim TFP-40 Series User manual

Teknim VAS-741B Instruction Manual

Teknim

Teknim VAS-741B Instruction Manual

Teknim VAP Series User manual

Teknim

Teknim VAP Series User manual

Popular Security System manuals by other brands

Kilsen KAL455 Installation sheet

Kilsen

Kilsen KAL455 Installation sheet

Senect VIS-LED manual

Senect

Senect VIS-LED manual

Kilsen KZ715AS Installation sheet

Kilsen

Kilsen KZ715AS Installation sheet

LaserShield Instant Security System owner's manual

LaserShield

LaserShield Instant Security System owner's manual

SecurityIng Universal CCTV Security Camera System installation guide

SecurityIng

SecurityIng Universal CCTV Security Camera System installation guide

Grace Industries WorkForce 1 User information

Grace Industries

Grace Industries WorkForce 1 User information

Louwice P9 Quick setup guide

Louwice

Louwice P9 Quick setup guide

june SIAI series Operating	 instruction

june

june SIAI series Operating instruction

AKCP 5ESV-X20 user manual

AKCP

AKCP 5ESV-X20 user manual

PCB Piezotronics IMI SENSORS 683A000001 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 683A000001 Installation and operating manual

Guardian Angel GA-253 user manual

Guardian Angel

Guardian Angel GA-253 user manual

Denver SHA-150 Quick user guide

Denver

Denver SHA-150 Quick user guide

Quantum VS2124 quick start guide

Quantum

Quantum VS2124 quick start guide

Optimal tracking Icare monitoring system user manual

Optimal tracking

Optimal tracking Icare monitoring system user manual

Ace DUALBRITE 3009701 user manual

Ace

Ace DUALBRITE 3009701 user manual

Precision Digital Corporation Vigilante II PD154 instruction manual

Precision Digital Corporation

Precision Digital Corporation Vigilante II PD154 instruction manual

Kentix MultiSensor-LAN user manual

Kentix

Kentix MultiSensor-LAN user manual

Fortress Automotive Security FS-60 Installation handbook

Fortress Automotive Security

Fortress Automotive Security FS-60 Installation handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.