TPC L700 Lucent Dental Light Operation manual

1
Advance Operatory
Dental Light
Operaon and service manual
TPC
851 S. Lawson St
City Of Industry, CA 91748
P626-810-4337 Fax 626-810-4245
www.tpcdental.com
REV. 1-1-13

2
TableonContents:Page
GENERALINFORMATION3
Installation4
Overviewofcomponents5
Operationinstructions6
Lightheadadjustment7
Verticalarmadjustment7
Replacementoflightbulb8
ReplacementPartsList9
CLEANING&DISINFECTINGGUIDE12
Warranty13
TROUBLESHOOTINGGUIDE14
TechnicalAssistanceisavailableMondaythrough
Friday,8:00Amto5:00PMPST.

Gene
Defin
ralInf
o
itions
o
AC(Alter
n
Riskofel
e
surepow
e
attemptin
Caution:
F
thedescri
damaget
o
operator.
Protectiv
e
o
rmatio
o
fsymb
n
atingCurre
n
e
ctricalshock
e
risdisconn
e
gthisproced
F
ailuretocar
e
bedprocedu
o
theequip
m
e
earth(Grou
n:
ols
n
t)
present.Ma
k
e
ctedbefore
ure.
e
fullyfollow
remayresul
t
m
entor
nd)
3
k
e
t
in
Produ
c
c
tIden
t
On
Off
TypeBequi
(Protected
a
Dangerous
V
t
ificatio
pment
a
gainstelect
r
V
oltage
n
r
icalshock)

4
OperatoryLightInstallation
•TheAdvanceOperatoryLightisdesignedtofitintothetopendofachairorfloor
mountedpost.Thesizeoftheincludedbushingis111/16”.Forallotherlight
postsizesyouwillneedtoobtainanadditionallightpostadaptorbushing.
•Inserttheendofwirethroughthesilverlightbushing.
•Placetheendofthewirethroughthelightpostandinsertthelightbushinginto
thelightpostandpressdowntoinsureproperseatingofthebushing.
•Attachlightheadwirestoverticalarmthisisa“whiteMolexconnection”.Insert
setscrewintolightheadtoattachlighttoverticalarm.
•Connectthewirestothecorrespondingterminalsontheplug.Orhardwirethe
connectionsusingtheincludedwirenuts.

5
Overviewofcomponents:
LightPost
Transformer
Housing
Transformerlid
Lightbushing
HorizontalArm
Light
Knuckle
Glass
Reflector
Deflector
PowerSwitch
LightHandle
VerticalArm

6
OperatingInstructions
•Movepowerswitchtothelefttosetthelighttohighintensity.Movethepower
switchbacktothecenterpositiontoturnittotheoffposition.Movethepower
switchtotherighttorighttoturnittolowintensity.
•Toadjustthepositionofthelight,placeyourhandonthelighthandleandmove
ittothedesiredlocation.Youcanmovethelightheadupanddownandleftand
right.Whenturningthelightheadleftandrightitwillstop,don’tforceany
furthermovementofthelightheadasdamagemayoccur.
•Tobringthelightclosertothepatientordesiredilluminatedlocationpulldown
onthelighthandletomovetheverticalarm.Oncethelightisinthedesired
locationIwillstayinthatpositionsuntilyoumoveitback.
Hi
g
hLow
Off

7
Lightheadadjustment
•Ifyouexperienceadownwarddriftwithyouroperatorylightheadpleasefollowthe
procedurebelow.
•Tightenbothsetscrewsonthebacksideoftheoperatorylight.Thereisonelocatedon
eachsideofthedentallighthead.Referenceimagebelow.Totightenthesetscrewturn
itclockwise.Donotovertightenthesetscrewasdamagemayoccur.
VerticalArmadjustment
•Ifyouexperienceadownwarddriftwithyouroperatorylightsverticalarmpleasefollow
theproducerbelow.
•Withonehandlowertheverticalarmtillyouseetheadjustment.Seeimagebelow.
Adjusttheinnernuttillthedesiredtensionisachieved.
Less tension More tension
Turntensionnutcounter
clockwiseifverticallight
armdriftsup.
Turntensionnut
clockwiseifverticallight
armdriftsdown.

8
Light Bulb replacement
•If you need to replace your operatory light bulb please follow the steps listed below.
•Remove the rear panel cover from the back of the light. Turn the thumb nut counter
clockwise to remove it.
Thumb Screw
•Remove the light bulb retaining spring by pushing it down then pulling it back towards
the center of the light bulb socket.
Retaining spring
•Once the spring is removed then disconnect the light bulb from the wire. Slide the high
temperature heat shield back to expose the light connection.
High temperature heat shield and light bulb connection.
•When handling the replacement light bulb be sure not to touch the glass as the oils on
your hands can damage the bulb. Reverse the above steps once the new bulb is in place.

9
Replacement Parts List
Index No. Part Number Description
1 L700-0001 Housing cover for transformer
2 P56004-700 110V Power Transformer
3 L700-0002 Transformer Housing
4 L700-0003 Horizontal Arm
5 L700-0004 Counter Sunk Pin
6 L700-0005 Swivel Arm Knuckle
7 L700-0006 Bridge ARM Connector
8 L700-0007 Set Screw (4 X 5 mm)
9 L700-0008 Yoke Joint Cover
10 L700-0009 Balance Arm Assembly
11 L700-0010 Set Screw (5 X 8 mm)
12 L700-0011 Wire Harness Balance Arm
13 L700-0012 Spring For Balance Arm

10

11
Index No. Part Number Description
1 L700-703 Light Shield
2 L700-702 Light Handle
3 L700-701 Light Head Yoke
4 L700-704 Frame
5 L700-705 Yoke Cover
6 L700-706 Frame Back Cover
7 L700-707 Yoke Wire Harness
8 L700-708 Power Switch
9 L700-709 Joint Nut
10 L700-710 Flat Washer
11 L700-711 Wave Washer
12 L700-712 Nut For Joint Bolt
13 L700-713 Yoke Side Cover (CAP)
14 L700-714 Spring Holder For Light Bulb
15 L700-P107 Halogen Light Bulb
16 L700-716 Ground Wire
17 L700-717 Lamp Socket
18 L700-718 Socket Housing
19 L700-719 Rubber Washer
20 L700-P705 Reflector
21 L700-721 Nut
22 L700-722 Deflector
23 L700-723 Wire Switch
24 L700-724 Screw
28 L700-723 Rubber She eel For Yoke
29 L700-729 Socket Holder

12
Cleaninganddisinfectingguide
Table1
*TheManufacturermakesnorepresentationastothedisinfectantefficacyoftheseproducts.
Wemakenowarrantyexpressedorimpliedthatthesedisinfectantswillnotdamagethe
surfacefinishes.Damageanddiscolorationofthesurfacefinishesarenotcoveredunderthe
warranty.Iodophor‐baseddisinfectantswillcauseyellowstainingonmanysurfaces.Regular
washingwithsoapandwaterwillminimizethisstaining.Iodophorneutralizerssuchas
Promedynearealsoavailable.
UnacceptableDisinfectants
Thesedisinfectantswillharmthesurface
finishesofdentalequipmentandarenot
recommended.
Useoftheseproductswillvoidyour
warranty.
ChemicalComposition/TradeNames
StrongPhenols/Lysol,Lysol2,Lysol
Phenol‐AlcoholProfessional,CoeFoam,Coe
combinationsSprayPump,Vitaphene,OmniII
SodiumHypochlorite/Clorox,Ajax,Purex
HouseholdBleach
Alcohol
HouseholdCleaners
ConditionallyAcceptableDisinfectants
Thesedisinfectantshavebeenfoundtobethe
least
harmfultotheequipmentsurfacesbyourtest
methods.
ChemicalCompositionTradeNames
IodophorsBiocide,Aseptic‐IDC,
Wescodyne,SD5,Promedyne,
Iodo‐Five
MildPhenolsProcideES,Asepti‐Steryl
Aerosol
Glutaraldehyde/SterallSpray,Coldspor
PhenolSprays
SynergizedSuperDis‐cide,Cavicide,
Kleenaseptic
Quat
Phenol/WaterSpraysTop‐Cide,SporicidinPump
Spray
Birexse

13
Warranty Information
All of our products sold are guaranteed to be free from defects in workmanship and materials for a 1 year
from date of purchase, unless otherwise stated. TPC will repair or replace any defective part at no
charge. TPC will not be responsible for labor charges or shipping charges to / from the TPC facility. This
guarantee does not cover normal wear or stains on surface finish. The guarantee does not cover damage
resulting from improper installation, misuse or accidents incurred in shipping and handling. All claims
against the freight carrier must be initiated at the time the damaged items are received. The claim is the
responsibility of the customer. We are improving our products on a continuous basis. We reserve the right
to make modifications without the need for prior notification and are not obliged to modify previously
manufactured items. Light bulbs are not covered under any type of warranty. Only authorized service
technicians should attempt to service TPC equipment. Service performed by any unauthorized technician
may result in a voided warranty.

14
TroubleshootingGuide.
Problem CauseSolution
Lightdoesnotilluminate Nopowertolight Checkpower
Lightbulbhasexpired Replacelightbulb
Transformerisexpired Replacetransformer
Onlyhighorlowfunction
works
Secondarywindingson
transformersareexpired
Replacetransformer
Mainpowerswitchisbad Replacemainpowerswitch
Lightturnsonandoffthen
thelightheadismoved
Shortoropeninpowerline
formtransformer.
Checkeachpowerlinefor
shortoropen.Thenreplace.
Lightheaddriftsdown Lightheadtensionspringsare
loose
Tightenlightheadspringnuts.
VerticalarmdriftsupordownVerticalarmtensionspring
needstobeadjusted
Adjustverticalarmtension.
Lightdriftsfromlefttoright Lightpostisnotlevel Levellightpost.
Table of contents
Other TPC Dental Equipment manuals

TPC
TPC Amalgamator D-650 Instruction and safety manual

TPC
TPC Amalgamator D-650 User manual

TPC
TPC LED 55BN User manual

TPC
TPC LED 39N User manual

TPC
TPC PC2635 Quick start guide

TPC
TPC PC 2530 User manual

TPC
TPC Laguna 2.0 User manual

TPC
TPC PC2630 User manual

TPC
TPC LED 70N User manual

TPC
TPC ProClean Extra Oral Suction User manual