I. Safety Information
In order to correctly use this instrument, please read this manual carefully
in detail. This manual includes the safety information related to the safe oper
-ation of the Tester, please strictly observe them when using the Tester.
Caution:
1. Please read and understand the contents of this manual before use.
2. Please keep this manual properly. It can be easily used for a test reference
when necessary.
3. Ensure to use the instrument in accordance with the test procedures
described in this manual.
4. Make sure you have understood the safety information details.
5. Ensure to strictly follow the safety regulations, or otherwise accidents or
instrument damage may occur.
6. The Instrument should be operated by qualified and trained personnel and
used only as specified in the manual.
7. UNI-T will not be liable for any damage to the instrument or losses caused by
misuse or operation not as specified in the manual or the safety regulations.
Safety mark has three meanings in the manual; when reading, user
will pay special attention to the operation relating to .
Danger: Specifies conditions and actions that most likely pose
hazards to the user.
Caution: Specifies conditions and actions that may cause minor
injury or damage to the Tester
Warning: Specifies conditions and actions that may pose hazards
to the user;
This instrument is only for the single phase within AC 230V/50Hz
195~253V .
When testing, do not touch any bared wire.
When testing, you can touch the tested conductor only in the safe
situation.
After the test is finished, Please disconnect the test lead from the
power supply. Do not leave the test lead connected to the power
supply for a long time.
Danger
Warning
Do not perform the tests with the Tester cover opened, for hazardous
voltage may be present. If the Tester work abnormally, please have it
checked and serviced by professional personnel.
If any anomaly happen(eg: missing display, unwanted data, casing
damage, test noise, etc), please contact the qualified servicing
personnel before proceeding any operation.
Before using the instrument, if your hand is wet, please do not use it.
please use only the certified test lead supplied with the Tester, prohibit
using other kinds of test wires.
Do not expose the instrument under sunshine, extreme temperature,
moisture and other severe environment.
Clean the Tester with dampened cloth and mild detergent; no abrasives
or solvents are allowed.
When the instrument is wet, please ensure it is dried before storage.
Caution
Electrical Symbols
Marks of danger, warning and caution
Double or reinforced insulation.
CE conforms to standard of European Union.
II. Product Features
2.0 Adopt intellectual micro-controller chip to maintain high accuracy,
high reliability and stability.
2.1 Wiring inspection (RCD test ):
2.2 Phase angle selection:
The tests can be performed at positive 0 or negative 180 phase angle.
2.3 Test locked:
When the test lead is disconnected, long press 0 / 180 (  )button to enable
the test function, then connect the test lead to tested terminals, the tests can
be automatically performed.
2.4 AUTO RAMP test:
Measure trip current and trip time simultaneously.
2.5 Over-Range Indication:
If the Tester fails to trip within Max. test time, the display shows  icon.
2.6 Data Hold:
The readings will be frozen when the test finishes.
2.7 Maximum current of test is up to 1A ( x1 Function).
2.8 Over-heat inspection:
When the related parts inside the instrument are over heated, LCD displays
and the instrument will automatically prohibit the tests, after it is cooled
down, LCD does not display and
the tests restart again.
2.9 Backlight :
Press LIGHT( ) to turn on /off the backlight. When under MANUAL RAMP
mode, press the button momentarily to turn on/off the backlight, or long press
to access I△n setup.
2.10 Low battery indication:
When voltage of battery is less than 7V, low-voltage sign is displayed,
please change the battery in time;
2.11 Auto power off :
The instrument will automatically power off after ten minutes' idling. To disable
the function, press and hold 0 / 180 button while turning on the instrument.
2.12 Fused protection.
III. Technical Specifications
3.1 Measurement Range and Accuracy:
Temperature: 23 5
Humidity:: 45%~75%RH
Altitude: 2,000m
Accuracy: ±(a% of readings +b digits)
10/20/30/100/200
/300/500mA/1000mA
10/20/30/100/200
/300mA
500mA/1000mA
0~2000mS0 / 180
0~2000mS0 / 180
0~200mS 0 / 180
0~200mS 0 / 180
10/20/30/100/200
/300mA/500mA
10/20/30/100/200
/300/500/1000mA
10/20/30/100/200
/300/500/1000mA
0/180
0~200mS
10/20/30/100/200mA
-10%~0%
0.6%
rdg
4dgt
-10%~+10%
-10%~+10%
0%~+10%
195~253V
/50Hz
Auto
Ramp
Manual
Ramp
Function Rated Trip Current
(I△n)
Working
voltage (AC)
Accuracy
Trip Time
Trip Time
Trip Current
1V
60 400V 500VAC/700VDC
5%+2
Function Range Resolution Accuracy Input
Protection Remarks
AC
voltage
Input Impedance
about 5.9M
LCD Indication Connection Status
40%~110% of Rated
Current, step at 5%;
300ms ×5;0 / 180
L-N&L-PE flash Abnormal power supply or no supply to
tested circuits
L-PE&N-PE flash, L-N doesn’t The tested terminals are badly or not
earthed.
L-N&N-PE flash, L-PE doesn’t Neutral terminal is disconnected
L-N,L-PE and N-PE flash Wrong wiring to tested terminals
The tester will prohibit the tests regarding the above status, except reverse
connection between earth and neutral terminals,
3.2 Function Selection
3.3 Compliances:
IEC 61010-1 CATIII 300V , Pollution Degree 2
IEC 61557-1, 5
IEC 61010-2-31
Caution:
1. Frequency Range for AC Voltage: 50~60Hz;
2. For AC voltage <60V, the reading is for reference only.
3.4 Working Voltage: 230VAC (Range: 195~253V)
3.5 Working Conditions: Temperature: 0 ~40
Relative Humidity: 80%RH
Altitude: 2000m
3.6 Storage Conditions: Temperature: -20 ~60
Relative Humidity: 75%RH
3.7 Dimensions: 210mm x 175mm x 90mm
3.8 Weight: About 1,000g
3.9 Accessories
Test Lead (1.5m)---------------------1
Manual-----------------------------------1
Gallus/Tool Case----------------------1
IV. Tester Description and Main Accessory
(See Figure1,2,3)
2
3
4
56
/
10m A 20m A 30m A 100m A 200m A 300m A 500m A 1000m A
Figure 1
Figure 2
Figure 3
7
V. RCD Test
Danger:
Do not touch any exposed earthing metal or conductor during the operation.
(7)Test locked:
When the test lead is disconnected, long press 0 / 180 ( )button to enable
the test locked function, then connect the test lead to tested terminals, the
tests can be automatically performed.
6.3 Press 0 /180 button to set the phase angle and repeat 6.1 to determine
the fastest trip time.
6.4 Press to change the phase angle and repeat 6.1
6.5 When the tests finish, disconnect the test lead from the tested circuit
immediately.
VI. Maintenance and Repair
6.2 Maintenance
Please contact UNI-T after-sale service center or agents if the following anomaly
happens:
A.Instrument case or parts are damaged.
B.LCD displays wrongly.
C.Unexpected data shows even under normal use.
D.Buttons do not work or produce confusing display.
E.Noises arise in testing.
This manual is allowed to be alternated without prior notice.
**ENG**
X1/2------------------Non-trip test, check RCD sensitivity
X1--------------------Measure trip time
X2--------------------Measure fast trip time at I△n×2 trip current
X5--------------------Measure fast trip time at I△n×5 trip current
AUTO RAMP Test----Measure trip current
MANUAL RAMP Test--measure trip time (at setting current)
0 / 180 /Lock Button
UP/DOWN Button: Set /Adjust the Current (under MANUAL RAMP)
LIGHT/SET Button(under MANUAL RAMP)
TEST Button
Rotary Switch
Input Terminals
Test Lead
LCD
(1)Test Lead Connections
Connect three connectors of the test lead respectively to three input terminals
of the Tester: Red—L, Green—E, Blue—N, then connect another terminal of
the test lead to tested circuit (230V/50Hz power socket).
(2)Voltage Test
Set the rotary switch to V position, The tester now can measure the voltage
between L and N terminals, which should fall within 195V-253V, if not, please
check if the wiring is correct before proceeding into next step
(3)Wiring Check
Turn the rotary switch to RCD ranges and check the wiring status indicated
on LCD.
LCD Indication Connection Status
L-N&L-PE flash Abnormal power supply or no supply to
tested circuits
L-PE&N-PE flash, L-N doesn’t The tested terminals are badly or not earthed.
L-N&N-PE flash, L-PE doesn’t Neutral terminal is disconnected
L-N,L-PE and N-PE flash Wrong wiring to tested terminals,
The tester will prohibit the tests regarding the above status, please check the
wiring and correct the connection before restart the tests.
(4) Press I△n UP( ) or DOWN( ) button to adjust the trip current(I△n) the
same as the rated trip current marked on RCD.
Default value: I△n 30mA 00(except MANUAL RAMP)
(5) When MANUAL RAMP is selected, the setup value“30mA” shows on lower
part of LCD, 40% of 30mA: “12mA” displays on right side, then use UP( ) or
DOWN( ) button to adjust the current within 40%~100% of the setup value at
a step of 5%; To change the setup value, long press “   ” button to access
current setup, “Set” icon shows on LCD, short press to set to 10mA,20mA,
30mA, 100mA, 200mA, 300mA, 500mA or 1000mA; long press the button
to exit the setup.
(6) Taking RCD Tests
6.1 Set the rotary switch to test parameters
● Non-Tripping ×1/2: Max. trip time up to 2000ms
● Tripping ×1: 10/20/30/100/200/300mA,: Max. trip time up to 2000ms
500/1000mA: Max. trip time up to 200ms
● Fast Tripping ×2 : Max. trip time up to 200ms
● Fast Tripping ×5 : Max. trip time up to 200ms
● AUTO RAMP Test: 40%~110% of rated trip current(I△n), Max. trip time up
to 300ms.
● MANUAL RAMP Test: Max. trip time up to 300ms.
6.2 Press TEST button
● Non-Tripping ×1/2-----The RCD should not trip.
● Tripping ×1: ---------The RCD should trip.
● Fast Tripping ×2 : -------- The RCD should trip.
● Fast Tripping ×5: ---------- The RCD should trip.
● AUTO Ramp Test: --------The RCD should trip, and trip time and trip current
are displayed simultaneously.
● MANUAL RAMP Test-------The RCD should trip.
(8) Backlight:
when testing on dimly lighted sites, press LIGHT(   ) to turn on /off the
backlight. Under MANUAL RAMP mode, press the button momentarily to turn
on/off the backlight, or long press to access I△n setup.
(9) Auto Power Off:
To disable the function, press and hold 0 / 180 button while turning on the
instrument, LCD will show “APO OFF” icon; the Tester usually defaults at
APO ON status(no pressing 0 / 180 button).
6.1 Cleaning the Casing:
Do not clean the instrument casing with any corrosive agents such alcohol or
solvent that may damage the display. Clean it with dry soft cloth and protect
the instrument from any moisture.
P/N:110401104490X DATE:2018.06.26 REV.2

Other Unit Test Equipment manuals

Unit UT890D User manual

Unit

Unit UT890D User manual

Unit UT 4000 Series User manual

Unit

Unit UT 4000 Series User manual

Unit UT522 User manual

Unit

Unit UT522 User manual

Unit UT90C User manual

Unit

Unit UT90C User manual

Unit UT501A User manual

Unit

Unit UT501A User manual

Unit UPO2102 User manual

Unit

Unit UPO2102 User manual

Unit MSO/UPO2000 Series Owner's manual

Unit

Unit MSO/UPO2000 Series Owner's manual

Unit UPO1000 Series User manual

Unit

Unit UPO1000 Series User manual

Unit UTD1000 Series User manual

Unit

Unit UTD1000 Series User manual

Unit UT513A User manual

Unit

Unit UT513A User manual

Unit UT659A User manual

Unit

Unit UT659A User manual

Unit UT527 User manual

Unit

Unit UT527 User manual

Unit UT-P35 User manual

Unit

Unit UT-P35 User manual

Unit UTD2025C User manual

Unit

Unit UTD2025C User manual

Unit UPO1000 Series User manual

Unit

Unit UPO1000 Series User manual

Unit UTD4000 Series User manual

Unit

Unit UTD4000 Series User manual

Unit UPO1000CS Series User manual

Unit

Unit UPO1000CS Series User manual

Unit UPO2000E Series User manual

Unit

Unit UPO2000E Series User manual

Unit UT528 User manual

Unit

Unit UT528 User manual

Unit UT712 User manual

Unit

Unit UT712 User manual

Unit UT3200+ Series User manual

Unit

Unit UT3200+ Series User manual

Unit UT311A User manual

Unit

Unit UT311A User manual

Unit UT526 User manual

Unit

Unit UT526 User manual

Unit UT5300X+ Series User manual

Unit

Unit UT5300X+ Series User manual

Popular Test Equipment manuals by other brands

Kaiweets HT106B user manual

Kaiweets

Kaiweets HT106B user manual

Circutor OT-60 instruction manual

Circutor

Circutor OT-60 instruction manual

Telegärtner UCT9 operating instructions

Telegärtner

Telegärtner UCT9 operating instructions

Canon imageFORMULA ScanFront 400 Service guide

Canon

Canon imageFORMULA ScanFront 400 Service guide

BMS 3000-OBC Operational manual

BMS

BMS 3000-OBC Operational manual

Charles Ischi AG AE-1 operating instructions

Charles Ischi AG

Charles Ischi AG AE-1 operating instructions

Project Fire Zonecheck Retrofit ZC450-R50 Instruction booklet

Project Fire

Project Fire Zonecheck Retrofit ZC450-R50 Instruction booklet

TIS E237 user manual

TIS

TIS E237 user manual

Dräger Aerotest 5000 Instructions for use

Dräger

Dräger Aerotest 5000 Instructions for use

YOKOGAWA CA51 HANDY CAL user manual

YOKOGAWA

YOKOGAWA CA51 HANDY CAL user manual

Kikusui TOS5200 Interface manual

Kikusui

Kikusui TOS5200 Interface manual

PCE Health and Fitness PCE-CBA 10 user manual

PCE Health and Fitness

PCE Health and Fitness PCE-CBA 10 user manual

Tektronix NetTek YBT100 user manual

Tektronix

Tektronix NetTek YBT100 user manual

VeEX FL41 Getting started guide

VeEX

VeEX FL41 Getting started guide

Zhangzhou Weihua DT5811 Operator's manual

Zhangzhou Weihua

Zhangzhou Weihua DT5811 Operator's manual

Siemens Cerberus NW8005 Technical manual

Siemens

Siemens Cerberus NW8005 Technical manual

ACT Meters GOLD-PLUS operating instructions

ACT Meters

ACT Meters GOLD-PLUS operating instructions

MULTI MEASURING INSTRUMENTS HCL-1000DM instruction manual

MULTI MEASURING INSTRUMENTS

MULTI MEASURING INSTRUMENTS HCL-1000DM instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.