ECS 3M
USER’S MANUAL
www.monitrol.com

Page 2
ECS-3M
Although the manufacturer has made every effort
to ensure the accuracy of the information
contained herein, this document is subject to
change without notice due to ongoing product
development.
WARNINGS AND PRECAUTIONS
Equipment, probe failure, blown fuses and/or
tripped breakers may prove harmful to the
contents of the building. Therefore it is strongly
recommended to install backup devices and alarm
or warning devices. Spare equipment should also
be available at the owner’s site. Equipment
manufactured by the manufacturer is protected
against normal line surges. High surges caused by
thunder storms or power supply equipment may
damage this equipment. For added security
against line voltage surges it is recommended that
surge and noise suppression devices be installed
at the electrical distribution panel. Use of shielded
cable for probes is recommended for protection
against lightning. These devices are available from
most electrical supply distributors.
RECOMMENDATIONS
The manufacturer recommends that all installation
procedures described herein be performed by a
qualified electrician or installation technician.
Further more the manufacturer recommends to
test all the functions and equipment connected to
the ECS, including the alarm system and backup
devices, after installation, after changes to the
installation and every month after that.
Fuse verification and replacement, as well as the
proper setting of control values shall be the
responsibility of the owner of this equipment.
www.monitrol.com

Page 3
CHAPTER 1 - INTRODUCTION
1. General ...........................................................................5
1.1 Description .......................................................................5
Definition of terms .........................................................................7
CHAPTER 2 - INSTALLATION
2.1 Unpacking ........................................................................9
2.2 Mounting ........................................................................10
2.3 Switch Settings................................................................10
2.3.1 Line Voltage Selector Switch ..........................................10
2.3.2 Software Settings Switch ................................................11
2.4 Connection Procedure ....................................................11
2.4.1 Input Power .....................................................................11
2.4.1.1 115 VAC..........................................................................11
2.4.1.2 230 VAC..........................................................................12
2.4.2 Fan 1 ...............................................................................12
2.4.3 Fan 2 ...............................................................................12
2.4.4 Fan 3/ Heater ..................................................................12
2.5 Temperature/Humidity Probes ........................................12
2.5.1 Single Temperature Probe..............................................13
2.5.2 Averaging ........................................................................13
2.5.3 Humidity Probe................................................................13
2.6 Alarm...............................................................................13
2.7 Powering Up....................................................................14
CHAPTER 3 - USER GUIDE
LED Status Window ........................................................20
Control Dials....................................................................20
PRIMARY FUNCTIONS
Main Set Point Temperature ...........................................23
Fan 1 Differential.............................................................24
Fan 1 Minimum Speed ....................................................25
Fan 1 Duty Cycle.............................................................26
Fan 2 Relative Set Point ................................................27
Fan 2 Differential.............................................................28
Fan 2 Minimum Speed ....................................................29
Heater/Fan 3 Relative Set Point......................................30
TABLE OF CONTENTS
www.monitrol.com

Page 4
ECS-3M
CONTENTS CONTINUED...
Reduction per day .......................................................... 31
Record Low Temperature .............................................. 32
Record High Temperature ............................................. 33
Room Temperature ....................................................... 34
SECONDARY FUNCTIONS
Relative Humidity Set Point............................................ 35
Fan 1 Motor .................................................................... 36
Fan 1 Minimum Humidity Speed .................................... 37
Fan 1 Duty Cycle Period ................................................ 38
Fan 2 Motor .................................................................... 39
Heater/Fan 3 Differential ................................................ 40
Minimum Ramping ......................................................... 41
Low Temperature Alarm................................................. 42
High Temperature Alarm ................................................ 43
Relative Humidity Display............................................... 44
APPENDIX
Motor Compatibility Table............................................................ 47
Troubleshooting........................................................................... 48
Specification ................................................................................ 49
Record Form ............................................................................... 50
www.monitrol.com

Page 5
1. GENERAL
This document provides a description of the ECS-3M
control panel. It is organized as follows:
•Introduction
•Installation
•User’s Guide
•Appendix
1.1 DESCRIPTION
Congratulations on the purchase of your ECS-3M
environmental control system. The ECS-M product line
provides you with full control over temperature, humidity,
air flow, and heat, resulting in a comfortable environment
for your livestock.
The ECS-M product line offers a number of added features
over existing ECS controls, such as:
•Compatibility with DIP-1 control.
•Hi/Lo temperature indication.
•Automatic temperature reduction (ramping).
•Adaptable variable speed outputs for a wide selection
of fan model types.
•Humidity probe.
•Full torque fan start to prevent motor damage.
The ECS-3M provides microprocessor control over a three
stage output.
The first stage controls a variable speed fan which can
operate at a continuous low speed to ensure good quality
of air when room temperature is below the main set point.
In addition, the first stage may be programmed to cycle
ON and OFF. When room temperature rises above the
main set point, the fan accelerates to increase the airflow.
CHAPTER 1 - INTRODUCTION
www.monitrol.com

Page 6
ECS-3M
DESCRIPTION CONTINUED...
The second stage provides control over a second variable
speed fan to help the first fan when higher room temperatures
require increased airflow. This second stage is also fully
programmable for settings, such as minimum speed, relative
set point, etc.
The third stage controls either a heater for colder climates, or
a third fan where additional cooling is required.
The ECS-3M provides you with full control over all three
stages via the use of an easy to follow display panel. All
programmable features can be customized to meet your
requirements. The ECS-3M keeps you constantly informed by
displaying the status of all of its outputs as well as the room
temperature. With an optional humidity probe, the ECS-3M
displays current humidity levels.
Safety of livestock is ensured by the continuous control of
climate and timely alarm notification, should environmental
conditions exceed alarm set points. Further security may be
obtained by connecting all ECS controls in a network
configuration to a computer via the use of an optional RCM-
40 remote monitoring unit . This provides remote control
monitoring of each room. All control panel variable outputs
are fused, and all programmable settings are maintained,
whether the ECS-3M is powered or not.
The ECS-3M provides an automatic constant temperature
reduction (ramping) feature for your maturing livestock. A
built-in low temperature safety factor prevents temperatures
from reaching dangerous limits.
With an ECS-3M in control of your climate, you are assured of
optimal living conditions for your livestock.
www.monitrol.com

Page 7
DEFINITION OF TERMS
DEFINITION OF TERMS
MAIN SET POINT
The desired room temperature. Other temperature
settings on the ECS-3M are relative to the main set
point temperature.
RELATIVE TEMPERATURE
A value added to, or subtracted from the main set
point, which results in a new temperature at which a
desired action starts or stops.
ROOM TEMPERATURE
The actual temperature in a closed area.
ROOM HUMIDITY
The actual humidity level of a closed area.
MINIMUM FAN SPEED
The desired minimum speed for variable speed fans.
RAMPING
An automatic daily reduction in the main set point and
all temperature settings relative to this.
DIFFERENTIAL
ON/OFF (relay). Range of temperature where two
conditions are possible. The output depends on
whether the temperature was increasing or decreasing
when it enters that range.
VARIABLE. (Bandwidth) Temperature range where a
variable fan speed fan accelerates, as the
temperature increases. Minimum value at relative set
point and 100% at relative set point + Bandwidth.
www.monitrol.com

Page 8
ECS-3M
www.monitrol.com

Page 9
CHAPTER 2 - INSTALLATION
Chapter 2 describes the installation of the ECS-3M
control panel.
2.1 UNPACKING
Unpack the ECS-3M and inspect contents for damage.
Should the contents appear to be damaged, contact
your local distributor for return procedures.
The package should contain the following standard
items:
•1 ECS-3M control.
•1 installed temperature probe (model number 2004-
1K).
•3 cable fasteners or fuses.
•1 Instruction manual.
The following optional items may be added:
•3 additional temperature probes for temperature
averaging,
•1 humidity probe. The ECS-3M requires the RHT-1
humidity probe for maximum accuracy of monitoring
and control of humidity levels.
The manufacturer recommends that the following
instructions be adhered to as closely as possible,
and that all work be performed by a certified
electrician. Failure to do so may void the warranty!
www.monitrol.com

Page 10
ECS-3M
2.2 MOUNTING
Use a screwdriver to remove the faceplate and the plate
on the power compartment.
Once both faceplates are off, install the mounting screw
on the wall and install the unit on it. Use two more screws
to secure the ECS-3M in place using the bottom mounting
holes.
2.3 SWITCH SETTINGS
The ECS-3M is configured for a variety of options via two
switches as follows:
2.3.1 - Line Voltage Selector Switch
This switch is located on the surface of the main (bottom)
board and adapts the control panel for 115 VAC or 230
VAC line voltage.
Refer to Figures 1, 2, and 3.
Mounting hardware is not shipped with the unit.
230V
115V
To limit the unit’s exposure to noxious gases, install the
unit in a hallway.
Make sure the unit is mounted right side up with the
cable entry holes facing down.
The ECS-3M operates in a temperature range of 32°F -
120 °F (0 °C - 50 °C).
The enclosure is watertight, it is not splash proof or
immersion proof. DO NOT WATER the control. Cover it
carefully with plastic when cleaning the room.
* It is prohibited to use overhead cables outside the building.
www.monitrol.com

Page 11
CHAPTER 2 - INSTALLATION
2.3.2 - Software Settings Switch
This switch is located at the rear of the control panel
faceplate and adjusts the following options.
1
2
3
4
Switch 1 Selects the Fahrenheit or Celsius
display for the front panel.
Switch 2 Locks/unlocks user settings. All settings except
for main set point, record low, and record high
are locked when this switch is OFF.
Switch 3 Selects between a Heater or Fan control on
stage three of the control panel.
Switch 4 With or without a humidity probe, DIP switch #4
must be ON.
2.4 CONNECTION PROCEDURE
For connection procedures which follow see figures 1 to 3.
2.4.1 - Input power
Use a screwdriver to remove cable knock-outs for cabling
installation to the control panel.
2.4.1.1 - 115 VAC
Make certain that the line voltage selector switch is set
to 115 VAC. Connect the power cable to terminals 7 and 8
on the main (bottom) board and connect the ground wire to
terminal 9 on the main board .
OFF ON
Fahrenheit
Settings locked
Stage 3 = Heat
Not used
Celsius
Setting unlocked
Stage 3 = Fan
Relative Humidity
Do not apply power to the control panel until all
connections have been completed!
OFF ON
www.monitrol.com

Page 12
ECS-3M
2.4.1.2 - 230 VAC
Make certain that the line voltage selector switch is
set to 230 VAC. Connect the power cable to terminals 7
and 8 on the main (bottom) board and connect the ground
wire to terminal 9 on the main board.
2.4.2 - Fan 1 (terminals 5 and 6)
Stage 1 of the ECS-3M controls the operation of the
primary fan. Connect the two leads from fan 1 to terminals
5 and 6 on the main (bottom) board.
2.4.3 - Fan 2 (terminals 3 and 4)
Stage 2 of the ECS-3M controls the operation of the
secondary fan. Connect the two leads from fan 2 to
terminals 3 and 4 on the main (bottom) board.
2.4.4 - Fan 3/Heater (terminals 1 and 2)
Stage 3 of the ECS-3M provides a dry contact closure
which controls the operation of a third fixed speed fan or a
heater. This contact closure is voltage rated to 230 VAC.
The current rating of the dry contact is 10 Amps (resistive)
for a heater and 6 Amps (inductive) for a fan. Set the
software settings DIP switch at the rear of the control
panel faceplate to ON for a fan or OFF for a heater.
Connect the heater or fan 3 to terminals 1 and 2 on the
main (bottom) board.
2.5 TEMPERATURE / HUMIDITY PROBES
Temperature and humidity probes use a “Class 2” low
voltage circuit. These cables can be extended to a
distance of 150 meters (500 feet). Single probe
temperature and humidity connections are illustrated in
figure 4, while temperature probe averaging connections
are illustrated in figure 5.
www.monitrol.com

Page 13
CHAPTER 2 - INSTALLATION
2.5.1 Single Temperature Probe
Install a single temperature probe in the area that best
reflects the overall room temperature. Connect the two
leads and the shield of the temperature probe to the
control panel terminals labeled “Probe”, as indicated in
figure 4.
2.5.2 Averaging (optional)
Four temperature probes are required if temperature
averaging is desired in larger rooms. Place the probes in
appropriate locations to best average room temperature.
Refer to figure 5.
2.5.3 Humidity Probe (optional)
Install one humidity probe in the area that best reflects the
overall room humidity. Connect the humidity probe to the
control panel terminals labeled “Probe”, as indicated in
figure 4.
2.6 ALARM
The ECS-3M provides a normally open and normally
closed dry contact for alarming low or high temperature
conditions. In addition, this same contact can be used to
signal a power failure. This contact may be connected to
an alarm system, or directly to a siren and/or auto-dialer.
Make normally open or normally closed connections as
indicated in figure 4.
Use shielded cabling for probes . Connect the shields
to the “SHLD” terminal. Failure to do so may result in
inaccurate readings!
Momentary power interruptions may trigger false
alarms! To avoid them, when the ECS-3M is connected
to an alarm system, install a time delay relay between
the ECS-3M and the alarm system.
www.monitrol.com

Page 14
ECS-3M
Fig. 1
Two Fans (115V) and One Heating Unit (115V)
2.7 POWERING UP
Before powering up the ECS-3M, install the faceplate to
the control’s enclosure using the six screws previously
removed.
Set Selector knob to position (12).
Upon power up, the unit will test its display by briefly
lighting all the segments of its LED. Make certain that
all segments light up.
Following the LED display test, the unit displays the
room temperature.
If the temperature does not appear, refer to the
Troubleshooting section in the appendix of this
document.
www.monitrol.com

Page 15
Fig. 2
Three Fans (230V)
Fig. 3
Two Fans (230V) and One Heating Unit (115V)
CHAPTER 2 - INSTALLATION
www.monitrol.com

Page 16
ECS-3M
Fig. 4.
Probes and Alarm Wiring
4
Notes for Figures 1, 2 and 3
Power cut and protection devices in case of overload.
Only use fans that have thermal protection devices.
Terminals 4, 6, and 7 are internally connected.
Connect the grounding wire to the ground terminal 9 .
Should be on a different circuit from the ECS.
1
2
4
3
5
www.monitrol.com

Page 17
Fig. 5
Temperature Averaging Probe Connection
Fig. 6
Main Board: Terminal, Blocks, Switches, Fuses and Ground
Probes IPM-1 Alarm
10A Slo-Blo
Fan 1
10A Slo-Blo
Fan 2
1046
Ground
Connection
CHAPTER 2 - INSTALLATION
www.monitrol.com

Page 18
ECS-3M
RECOMMENDED CONTROL BACKUP
WARNING AND PRECAUTIONS
Equipment failure, blown fuses and/or tripped breakers
may prove harmful to the content of the building. It is
therefore strongly recommended to install backup devices
and alarm or warning devices (see example fig. 7).
BACKUP THERMOSTAT. If the control is defective, then
the thermostat will start the dedicated fan at full speed
when the temperature will reach the T15-WD set value.
Therefore, the T15-WD should be accessible for its
adjustment and it should be set at the same temperature
as the alarm, i.e. approximately 5ºC above the fan relative
set point.
BACKUP POWER SOURCE. The DPDT relay connects
to the source 1 in normal operation but will switch to the
source 2 if source 1 is off. The relay shall be chosen to
support the load connect to it.
ALARM CIRCUIT. In normal operation, the alarm circuit of
the Varifan control is a short circuit. But if the control is
defective or if there is no power applied to it, then the
alarm circuit of the control will be an open circuit.
www.monitrol.com

Page 19
Fig 7.
Recommended control backup
CHAPTER 2 - INSTALLATION
www.monitrol.com

Page 20
ECS-3M
CHAPTER 3 - USER’S GUIDE
The ECS-3M front panel shown previously features a
LED status window and two control dials which are used
respectively to select a function and adjust a setting.
LED STATUS WINDOW
The LED status window features a 3 digit LED readout for
the display of temperature in Fahrenheit or Celsius,
humidity level, and programmable settings.
In addition, the LED status window displays the
operational status of Fans 1, 2, and Fan 3 or a heater via
four additional LEDS (shown above in LED window).
When ON, each LED indicates that its associated fan or
heater is operating. The fourth LED lights up to indicate a
low or high temperature alarm condition.
CONTROL DIALS
The center dial is the Selector dial and is used to select
one of the control panel’s 12 primary or 10 secondary
functions. The dial located to the right of the Selector dial
is the Adjuster dial and is used to enter secondary
function mode and to adjust the setting of each function.
www.monitrol.com
Other manuals for ECS 5M
1
Table of contents
Other Varifan Control System manuals

Varifan
Varifan DIP-1C Operation manual

Varifan
Varifan IC-68ND User manual

Varifan
Varifan MST-5C User manual

Varifan
Varifan ECS-4+ User manual

Varifan
Varifan ECS 5M User manual

Varifan
Varifan CM10-2 User manual

Varifan
Varifan ECS-2M User manual

Varifan
Varifan ECS-1M User manual

Varifan
Varifan IC-664 User manual

Varifan
Varifan VPM-1 User manual