warema_2016156_alhb_en_v3•2022-05-01 We reserve the right to make technical modifications
 the housing or the connecting lines show
signs of damage,
 the device is no longer working.
ARNINGW
It is important to comply with the fol-
lowing points in the interest of personal
safety.
Children may not play with the operating elements of
the control unit or the remote control. Store remote
controls out of reach of children.
Make sure that no persons or objects are in the path
of the driven parts (venetian blinds, external venetian
blinds, etc.).
Disconnect the device from the operating voltage if
cleaning or other maintenance work must be per-
formed.
Function of the sun shading actuator
You will find a detailed description of the software func-
tions for the KNX sun shading actuators in the manual
(art. no. 2014 788). You can download the manual and
the product database of the sun shading actuator from
www.warema.com.
Installation
The device is intended for installation in a distribution
cabinet. The unit is installed by clipping it onto a DIN rail
(TH 35-15).
Electrical connection
An on-site overload current protection device (fuse) and a
disconnecting and isolating switch to switch off the entire
system must be provided.
The electrical connection is made as shown in the wiring
diagram on the reverse side (Fig. 5), the connection to
the KNX bus system and the drives is made using spring
terminals, the connecting lines are designed as screw
terminals.
WARNING
All terminals and connections under cur-
rent must be covered completely against
touching by the switch panel. It should
not be possible to open the switch panel
cover without using tools.
General information
Fig. 1 KNXSA8M230 REG
The KNXSA2/4/6/8M230REG sun shading actuator is
a device for the central operation of up to eight sun shad-
ing drives (the following uses the sun shading actuator for
eight motors as an example).
The device is operated using a KNX bus system. The
drives and the motor control unit are supplied via a
230VAC control line.
Intended use
The KNXSA2/4/6/8M230 REG was developed to control
sun shading products. The approval of the manufacturer
must be obtained for uses outside of the purposes listed
in these instructions.
The sun shading actuator is intended for installation in
enclosed electrical operating facilities.
Safety instructions
WARNING
The electrical installation (assembly)/dis-
mantling must be performed by a certified
electrician in accordance with the electri-
cal installation regulations published by
the Association of German Electrical En-
gineers (VDE 0100) or the standards and
legal requirements of the country in which
the device is being installed. The electri-
cian must observe the installation instruc-
tions included with the supplied electrical
devices.
WARNING
If hazard-free operation cannot be as-
sumed, the device may not be started or
must be deactivated. This assumption is
justified if:
Installation instructions
KNX SA 2/4/6/8M230 REG
Valid from
1 May 2022
Keep for future use.
warema_2016156_alhb_en_v3•2022-05-01We reserve the right to make technical modifications
2
Commissioning
After the installation has been completed and the operat-
ing voltages have been applied, the device can be oper-
ated using a keypad (Fig. 2).
You will find a detailed description on the further commis-
sioning in the KNX manual (art. no. 2014 787).
Local operation
The keypad has 4 buttons, the Up / Down / Select and
Prog buttons, and an LED. The Select button is used to se-
lect the channel. The selected channel is displayed by one
of the 8channel LEDs. If the SEL button is pressed again
after selecting channel8, all channels are selected.
Fig. 2 Keypad
Local operation on the device has the same priority as
manual operation via communication objects. The operat-
ing behaviour is the same as the "KNX behaviour":
Brief push of the button = Step / Stop,
Long push of the button = Move.
WARNING
Never randomly press the buttons on the
keypad without having a line of sight to
the sun shading system.
Programming
 Press the programming button (Fig. 2) to put the
device into programming mode. The LED lights up
red when programming mode is active. The device is
programmed on a PC using the ETS. This software
ends the programming mode automatically. The red
LED goes out.
 If the programming mode is to be ended earlier, press
the programming button again. The red LED goes out.
Maintenance
There are no parts inside the device that require mainte-
nance. In the event of a malfunction, the built-in miniature
fuses should only be changed by a certified electrician.
Cleaning
Clean the housing with a soft, dry cloth. Do not use deter-
gents, cleaning agents, solvents, abrasive substances or
steam cleaners!
Liability
Failure to comply with the product information in these in-
structions and any use of the device other than its intend-
ed use may result in the manufacturer refusing to honour
warranty claims for product damage. In this case, liability
for consequential damage to persons or property will also
be excluded. Observe the information in the operating
instructions for your sun shading system. The automatic
or manual operation of the sun shading system while iced
over as well as using the sun shading system during se-
vere weather may cause damage and must be prevented
by the user through suitable precautions.
Obligations for the disposal of electrical
devices
A marking with this symbol indicates the following
obligations under the scope of legal regulations:
 The owner of this electrical device must dispose of it
separately from unsorted municipal waste for further
recycling.
 Used batteries and accumulators that are not enclosed
in the old device, as well as lamps/bulbs that can be
removed from the old device without breaking, must be
disposed of separately.
 Distributors of electrical devices and disposal compa-
nies are obliged to take back the equipment free of
charge
.
 The owner must take it upon themselves to delete any
personal data contained in the electrical device prior to
disposal.
3
warema_2016156_alhb_en_v3•2022-05-01 We reserve the right to make technical modifications
Technical data
KNXSA2/4/6/8M230 REG min. typ. max. Unit
Operating voltage 198 230 253 VAC
Mains frequency 50 50 60 Hz
Power consumption at 230VAC for
2M230 REG 1,4 1,9 W
4M230 REG 1,4 2,5 W
6M230 REG 1,4 3,0 W
8M230 REG 1,4 3,5 W
Power consumption in
standby mode
0.7 1.3 2.4 W
Output per drive*
Switching capacity
230VAC/cosφ =0.6
500 VA
*The total power per fuse must not exceed 1000 VA.
Interface KNX TP 1
Current consumption KNX 3.5 13 mA
Voltage 29 VDC
Ambient conditions
Operating temperature 0 50 °C
Storage temperature 0 70 °C
Humidity
(not condensing)
10 40 85 %Frel
Degree of soiling 2
Connection
Connecting line Screw terminals
KNX bus system, drives Spring terminals
Wire cross sections
Connecting line 230VAC max. 2.5mm²
KNX bus system 0.6–0.8mm∅
Motor outputs max. 1.5mm²
Housing Degree of protection
DIN rail-mounted housing IP30
Safety class
(PE is looped through)
I
Miscellaneous
Conformity
can be viewed at www.warema.de/ce
This device complies with the EMC directives for use in
residential and commercial areas.
Location of use clean ambient conditions
Article numbers
KNXSA2M230 REG 2014 568
KNXSA4M230 REG 2014 570
KNXSA6M230 REG 2014 574
KNXSA8M230 REG 2014 576
WAREMA Renkhoff SE
Hans-Wilhelm-Renkhoff Strasse 2
97828 Marktheidenfeld
Germany
60 mm
95 mm
90 mm
106 mm / 6 MW
60 mm
Fig. 3 Dimensions of 6 MW DIN rail-mounted housing for
KNX SA 6M230 REG and KNX SA 8M230 REG
60 mm
95 mm
90 mm
72 mm
4 MW
60 mm
Fig. 4 Dimensions of 4 MW DIN rail-mounted housing for
KNX SA 2M230 REG and KNX SA 4M230 REG.
Fuse protection
KNXsunshading actuator type number fuse protection
KNXSA2M230 REG 1 x 6,3 A
KNXSA4M230 REG 1 x 6,3 A
KNXSA6M230 REG 2 x 6,3 A
KNXSA8M230 REG 2 x 6,3 A
warema_2016156_alhb_en_v3•2022-05-01We reserve the right to make technical modifications
4
KNX SA 8M230 REG
X5
X1
X6
F1
6,3 AT H
L
N
PE
Supply line
230 V AC,
50/60 Hz, 16 A,
3 x 1.5 mm2
F2
6,3 AT H
F1
6,3 AT H
F2
6,3 AT H
M∼ M∼
Motor 1
sun shading system
Motor 2
sun shading system
1 32
BU BK BN GNYE
N
1 32
BU BK BN GNYE
PE NPE
M∼
Motor 3
sun shading system
1 32
BU BK BN GNYE
NPE
M∼ M∼
Motor 5
sun shading system
Motor 6
sun shading system
1 32
BU
BK BN GNYE
N
1 32
BU
BK BN GNYE
PE N PE
M∼
Motor 7
sun shading system
1 32
BU
BK BN GNYE
NPE
M∼
Motor 8
sun shading system
1 32
BU
BK BN GNYE
N PE
M∼
Motor 4
sun shading system
1 32
BU BK BN GNYE
NPE
KNX-
KNX+
-
+-
+
N
ATTENTION:
Only one motor can be connected per
motor terminal set.
If interconnected, the motor will
be damaged!
The total power per fuse must not
exceed 1000 VA.
All motor lines
H05-RR-F 4 G 0.75 black,
type WAREMA
All bus lines
YCYM 2×2×0,8 mm
KNX Bus KNX Bus
M1.1
M1.2
M2.1
M2.2
X2
L
M3.1
M3.2
M5.1
M5.2
M6.1
M6.2
M7.1
M7.2
M4.1
M4.2
M8.1
M8.2
KNX SA 6M230 REG
X5
X1
X6
F1
6,3 AT H
F2
6,3 AT H
KNX-
KNX+
N
M1.1
M1.2
M2.1
M2.2
X2
L
M3.1
M3.2
M4.1
M4.2
M5.1
M5.2
M6.1
M6.2
Motor allocation KNX SA 6M230 REG
Fig. 5 Connection example KNXSA8M230 REG

This manual suits for next models

3

Other WAREMA Controllers manuals

WAREMA KNX SA 2M230 AP Series User manual

WAREMA

WAREMA KNX SA 2M230 AP Series User manual

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA KNX SA 16M230 SMI REG User manual

WAREMA

WAREMA KNX SA 16M230 SMI REG User manual

WAREMA KNX MSE 6M230 Series User manual

WAREMA

WAREMA KNX MSE 6M230 Series User manual

WAREMA LONMSE 2M230I Manual

WAREMA

WAREMA LONMSE 2M230I Manual

WAREMA 1MPF.4 UP User manual

WAREMA

WAREMA 1MPF.4 UP User manual

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA WMS SA 1 UP User manual

WAREMA

WAREMA WMS SA 1 UP User manual

WAREMA KNX SA 2M230 REG User manual

WAREMA

WAREMA KNX SA 2M230 REG User manual

WAREMA BACnet 4M230.8I AP User manual

WAREMA

WAREMA BACnet 4M230.8I AP User manual

WAREMA LONMPM 8DI User manual

WAREMA

WAREMA LONMPM 8DI User manual

WAREMA KNX secure Series User manual

WAREMA

WAREMA KNX secure Series User manual

WAREMA KNX secure Series User manual

WAREMA

WAREMA KNX secure Series User manual

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA KNX SA Series User manual

WAREMA

WAREMA KNX SA Series User manual

WAREMA Omnexo 2M230 REG User manual

WAREMA

WAREMA Omnexo 2M230 REG User manual

WAREMA 4M230.12 2Down REG User manual

WAREMA

WAREMA 4M230.12 2Down REG User manual

WAREMA KNX SA 4MDC REG User manual

WAREMA

WAREMA KNX SA 4MDC REG User manual

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA Omnexo 2M230 AP User manual

WAREMA

WAREMA Omnexo 2M230 AP User manual

WAREMA LONMSE 2M230 Manual

WAREMA

WAREMA LONMSE 2M230 Manual

WAREMA LONMSE 6M230 User manual

WAREMA

WAREMA LONMSE 6M230 User manual

WAREMA Omnexo 1M230 UP User manual

WAREMA

WAREMA Omnexo 1M230 UP User manual

WAREMA KNX 2024236 User manual

WAREMA

WAREMA KNX 2024236 User manual

Popular Controllers manuals by other brands

Siemens RDF870KN operating instructions

Siemens

Siemens RDF870KN operating instructions

SEFRAM SDS3 quick start guide

SEFRAM

SEFRAM SDS3 quick start guide

Enttec DATAGATE MK2 Quick start manual

Enttec

Enttec DATAGATE MK2 Quick start manual

Pepperl+Fuchs KFD0-SD2-Ex2.1 45 Series manual

Pepperl+Fuchs

Pepperl+Fuchs KFD0-SD2-Ex2.1 45 Series manual

3Ware 9590SE Series User guide addendum

3Ware

3Ware 9590SE Series User guide addendum

Lumel re72 series Quick start manual

Lumel

Lumel re72 series Quick start manual

Lorenz MAGNUM Pro HD WARNING AND INSTALLATION MANUAL

Lorenz

Lorenz MAGNUM Pro HD WARNING AND INSTALLATION MANUAL

sema WPC 11+ quick start guide

sema

sema WPC 11+ quick start guide

OPTO 22 groov EPIC user guide

OPTO 22

OPTO 22 groov EPIC user guide

GeoVision GV-AS1520 quick start guide

GeoVision

GeoVision GV-AS1520 quick start guide

Controlli DuraDrive MX40-7 manual

Controlli

Controlli DuraDrive MX40-7 manual

JUMO IMAGO 500 Interface description

JUMO

JUMO IMAGO 500 Interface description

Beckett HeatManager 2.5 7514 installation instructions

Beckett

Beckett HeatManager 2.5 7514 installation instructions

Phason PEC User manual and installation guide

Phason

Phason PEC User manual and installation guide

Helmholz 700-651-CAN01 manual

Helmholz

Helmholz 700-651-CAN01 manual

Midi Solutions F8 operating instructions

Midi Solutions

Midi Solutions F8 operating instructions

Doms PSS 5000 installation guide

Doms

Doms PSS 5000 installation guide

Huawei ECC500 user manual

Huawei

Huawei ECC500 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.