Installation instructions
KNX SA 2/4/6/8M230.x AP
Keep for future use!
Valid from 1st February 2020
2016157_b•en•2020-02-01 We reserve the right to make technical changes 1
ARNINGW
It is important to comply with the following
points in the interest of personal safety.
 Children may not play with the operating elements of
the control unit or the remote control. Store remote
controls out of reach of children.
 Make sure that no persons or objects are in the range
of movement of the driven parts (blinds, external vene-
tian blinds, etc.).
 Disconnect the device from the operating voltage if
cleaning or other maintenance work must be per-
formed.
Function of the sun shading actuator
You will find a detailed description of the software func-
tions for the KNX sun shading actuators in the manual
(art. no. 2014 787). You can download the manual and
the product database of the sun shading actuator from
www.warema.com.
Installation
Insert a slotted screwdriver (recommendation: 3.0 -
4.0mm blade) into a cover opening (Fig. 3) and carefully
pry open the hinged cover. Repeat the procedure for the
second opening of the cover. After both latches have been
unlatched,
the cover can be removed. Open the second cover in
the same way. Alternatively, the AP model may also be
mounted on a DIN rail (TH 35-15 in accordance with EN
60715: 2001).
Electrical connection
An on-site overload current protection device (fuse) and a
disconnecting and isolating switch to switch off the entire
system must be provided.
The electrical connection is made as shown in the wiring
diagram on the reverse side (Fig. 4), the connection to
the KNX bus system and the drives is made using spring
terminals, the connecting lines are designed as screw
terminals.
ARNINGW
All terminals and connections under cur-
rent must be covered completely against
touching by the latched cover. It should not
be possible to open the latched cover with-
out using tools.
General information
Fig. 1 KNXSA8M230.16 AP
The KNXSA2/4/6/8M230.xAP sun shading actuator is a
device for the central operation of up to eight sun shad-
ing drives 230VAC (the following uses the sun shading
actuator for eight motors with 16 push button inputs as an
example).
The device is operated using a KNX bus system. The
drives and the motor control unit are supplied via a
230VAC control line.
Intended use
The KNXSA2/4/6/8M230.xAP was developed to control
sun shading products. The approval of the manufacturer
must be obtained for any use of the device other than its
intended purpose specified in these instructions.
Safety instructions
ARNINGW
The electrical installation must be per-
formed by a certified electrician in accord-
ance with the electrical installation regu-
lations published by the Association of
German Electrical Engineers (VDE0100)
or the standards and legal requirements
of the country in which the device is being
installed. The electrician must observe the
installation instructions included with the
supplied electrical devices.
ARNINGW
If hazard-free operation cannot be
assumed, the device may not be started or
must be deactivated. This assumption is
justified if:
the housing or the connecting lines show signs of
damage,
the device is no longer working.
2016157_b•en•2020-02-01We reserve the right to make technical changes
2
Commissioning
After the installation has been completed and the operat-
ing voltages have been applied, the connected drives can
be checked via Bluetooth using an app.
You will find a detailed description on the further commis-
sioning in the KNX manual (art. no. 2014 787).
Local operation
You will find the app for operating the KNX sun shading
actuator in the Apple AppStore and in the Google Play
Store.
Download this on your smartphone.
After starting the app, the surrounding area is scanned for
WAREMA sun shading actuators. Available actuators are
shown and can be operated.
Operation via app has the same priority as manual opera-
tion via group objects. The operating behaviour is as
follows:
Brief push of the button = Stop/step move command
Long push of the button = Up/Down move command.
A detailed description of the operation is integrated in the
app and can also be found in the associated KNX manual
(art. no. 2014 788).
OTICEN The communication between the smartphone
and the KNX devices is established via Blue-
tooth. This function can be switched off using
the ETS (in default mode, the function is always
"On").
During parameterization, change the default
password in accordance with your specifica-
tions and memorize your password in order to
prevent operation by unauthorized persons.
ARNINGW
Never randomly press the keys on the app
without having a line of sight to the sun
shading system.
Programming
You can perform programming either in the app or directly
on the device.
There is a Prog button for programming and a display LED
both in the app and on the keypad (see Fig. 2).
The procedure here is basically the same:
 Press the programming button in the app or on the
device (Fig. 2) to put the device into programming
mode. The red LED lights up when programming mode
is active. Programming is performed using the ETS on
the PC. This software ends the programming mode
automatically. The red LED goes out.
 If the programming mode is to be ended earlier, press
the programming button again. The red LED goes out.
Fig. 2 View of the keypad
Maintenance
There are no parts inside the device that require mainte-
nance. In the event of a malfunction, the built-in miniature
fuses should only be changed by a certified electrician.
Liability
Failure to comply with the product information in these in-
structions and any use of the device other than its intend-
ed use may result in the manufacturer refusing to honour
warranty claims for product damage. In this case, liability
for consequential damage to persons or property will also
be excluded. Observe the information in the operating
instructions for your sun shading system. The automatic
or manual operation of the sun shading system while iced
over as well as using the sun shading system during se-
vere weather may cause damage and must be prevented
by the user through suitable precautions.
Disposal
After use, the device must be disposed of according to
legal regulations or turned in to your local recycling centre.
3
2016157_b•en•2020-02-01 We reserve the right to make technical changes
Technical data
KNXSA2/4/6/8M230.x AP min. typ. max. Unit
Operating voltage 198 230 253 VAC
Mains frequency 50 50 60 Hz
Power consumption in
standby mode
0.7 1.3 2.3 W
Output per drive*
Switching capacity
230VAC/cosφ =0.6
500 VA
*The total power per fuse must not exceed 1000 VA.
Interface KNX TP 1
Current consumption KNX 3.5 13 mA
Voltage 29 VDC
Inputs on local operating elements (sunblind push buttons,
1-pin) and signal inputs
Voltage, active 8 24 36 VDC
Current, active 0.5 1 1.5 mA
Voltage, inactive -0.5 0 1 VDC
Bluetooth transceiver
Transmission frequency 2.402 2.480 GHz
Transmission power 0 dBm
Input sensitivity -90 dBm
Operating range (environ-
ment without interference)
5 m
Conformity can be viewed at www.
warema.com
This device complies with the EMC directives for use in
residential and commercial areas.
Ambient conditions
Operating temperature 0 50 °C
Storage temperature 0 70 °C
Humidity
(not condensing)
10 40 85 %Frel
Connection
Connecting line Screw terminals
KNX bus system, drives,
push button inputs
Spring terminals
Wire cross sections
Connecting line max. 2.5mm²
KNX bus system 0.6 - 0.8mm∅
Motor outputs, push but-
ton inputs
max. 1.5mm²
Housing Degree of protection
Surface-mounted housing IP30
Safety class
(PE is looped through)
I
Miscellaneous
Automatic operation Type 1
Software class A
Location of use clean ambient conditions
Article numbers
KNXSA2M230.4 AP 2014 569
KNXSA4M230.8 AP 2014 571
KNXSA6M230.12 AP 2014 575
KNXSA8M230.16 AP 2014 577
WAREMA Renkhoff SE
Hans-Wilhelm-Renkhoff Strasse 2
97828 Marktheidenfeld, Germany
210 mm *
119 mm
184 mm *
180 mm
60 mm
3 ‒ 4 mm
*KNX SA 2M230.4 AP 106 mm / 80 mm 6MW
KNX SA 4M230.8 AP 158 mm / 132 mm 9MW
KNX SA 6M230.12 AP: 210 mm / 184 mm 12MW
KNX SA 8M230.16 AP: 210 mm / 184 mm 12MW
Fig. 3 Dimensions
Fuse protection
KNXsunshading actuator type number fuse protection
KNXSA2M230.4 AP 1 x 6,3 A
KNXSA4M230.8 AP 1 x 6,3 A
KNXSA6M230.12 AP 2 x 6,3 A
KNXSA8M230.16 AP 2 x 6,3 A
2016157_b•en•2020-02-01We reserve the right to make technical changes
4
231
BU BK BN GNYE
M∼
Motor 1
sun shading system
231
M∼
Motor 2
sun shading system
NPE NPE
231
M∼
Motor 3
sun shading system
231
M∼
Motor 4
sun shading system
NPE NPE
Attention:
Only one motor can be connected per
motor terminal set.
If interconnected,
the motor will be damaged.
The total power per fuse must not
exceed 1000 VA.
All motor lines
H05-RR-F 4 G 0.75 black
type WAREMA
Supply line
230 V AC,
50/60 Hz, 16 A,
3 x 1.5 mm2
231
M∼
Motor 5
sun shading system
231
M∼
Motor 6
sun shading system
NPE NPE
PE
N
L
BU BK BN GNYE BU BK BN GNYE BU BK BN GNYE BU BK BN GNYE BU BK BN GNYE
X1
M1.1
M1.2
N
M2.1
PE
N
PE
M2.2
KNX SA 8M230.16 AP
PE
N
PE
N
L
L
M3.1
M3.2
N
M4.1
PE
N
PE
M4.2
M5.1
M5.2
N
M6.1
PE
N
PE
M6.2
F1
6,3 AT H
6,3 AT H
231
M∼
Motor 7
sun shading system
231
M∼
Motor 8
sun shading system
NPE NPE
M7.1
M7.2
N
M8.1
PE
N
PE
M8.2
F2
BU BK BN GNYE BU BK BN GNYE
X2 X3 X4
All push button lines
JY(St)Y 2x2x0.8 mm,
max. line length 200 m,
for interference-proof routing,
use a twisted paired line.
X5
In1.1
In+
In1.2
In2.1
In3.1
In4.1
In4.2
In3.2
In2.2
In+
In+
In+
Binary inputs freely
usable in KNX
X6 X7 X8
In+
In+
In5.1
In5.2
In6.1
In6.2
In+
In+
In7.1
In7.2
In8.1
In8.2
KNX-
KNX+
-
+-
+
All bus lines
YCYM 2×2×0.8 mm
KNX Bus KNX Bus
KNX SA 6M230.16 AP
PE
N
PE
N
L
L
F1
6,3 AT H
6,3 AT H
F2
X5
In1.1
In+
In1.2
In2.1
In3.1
In4.1
In4.2
In3.2
In2.2
In+
In+
In+
X6 X7 X8
In+
In+
In5.1
In5.2
In6.1
In6.2
In+
In+
In7.1
In7.2
In8.1
In8.2
KNX-
KNX+
X1
M1.1
M1.2
N
M2.1
PE
N
PE
M2.2
M3.1
M3.2
N
M4.1
PE
N
PE
M4.2
M5.1
M5.2
N
M6.1
PE
N
PE
M6.2
N
PE
N
PE
X2 X3 X4
Motor allocation KNX SA 6M230.16 AP
Fig. 4 Connection example KNXSA8M230.16 AP

This manual suits for next models

11

Other WAREMA Controllers manuals

WAREMA KNX SA 2M230 REG User manual

WAREMA

WAREMA KNX SA 2M230 REG User manual

WAREMA KNX secure Series User manual

WAREMA

WAREMA KNX secure Series User manual

WAREMA LONMSE 6M230 User manual

WAREMA

WAREMA LONMSE 6M230 User manual

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA BACnet 4M230.8I AP User manual

WAREMA

WAREMA BACnet 4M230.8I AP User manual

WAREMA KNX 2024236 User manual

WAREMA

WAREMA KNX 2024236 User manual

WAREMA KNX SA 2M230 REG User manual

WAREMA

WAREMA KNX SA 2M230 REG User manual

WAREMA KNX secure Series User manual

WAREMA

WAREMA KNX secure Series User manual

WAREMA KNX MSE 6M230 Series User manual

WAREMA

WAREMA KNX MSE 6M230 Series User manual

WAREMA KNX SA 4MDC REG User manual

WAREMA

WAREMA KNX SA 4MDC REG User manual

WAREMA Omnexo 1M230 UP User manual

WAREMA

WAREMA Omnexo 1M230 UP User manual

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA

WAREMA KNX SA 4MDC.8 AP User manual

WAREMA LONMPM 8DI User manual

WAREMA

WAREMA LONMPM 8DI User manual

WAREMA Omnexo 2M230 REG User manual

WAREMA

WAREMA Omnexo 2M230 REG User manual

WAREMA 1MPF.4 UP User manual

WAREMA

WAREMA 1MPF.4 UP User manual

WAREMA Omnexo 2M230 AP User manual

WAREMA

WAREMA Omnexo 2M230 AP User manual

WAREMA LONMSE 2M230I Manual

WAREMA

WAREMA LONMSE 2M230I Manual

WAREMA LONMSE 2M230 Manual

WAREMA

WAREMA LONMSE 2M230 Manual

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA

WAREMA KNX SA 16M230.32 SMI AP User manual

WAREMA KNX SA 16M230 SMI REG User manual

WAREMA

WAREMA KNX SA 16M230 SMI REG User manual

WAREMA WMS SA 1 UP User manual

WAREMA

WAREMA WMS SA 1 UP User manual

WAREMA 4M230.12 2Down REG User manual

WAREMA

WAREMA 4M230.12 2Down REG User manual

WAREMA KNX SA Series User manual

WAREMA

WAREMA KNX SA Series User manual

Popular Controllers manuals by other brands

Mi-Wave 511 Series user guide

Mi-Wave

Mi-Wave 511 Series user guide

Circutor computer max 6f manual

Circutor

Circutor computer max 6f manual

IBA ibaPADU-S-CM manual

IBA

IBA ibaPADU-S-CM manual

EnvironmentalLights.com rgb-mini-BT user manual

EnvironmentalLights.com

EnvironmentalLights.com rgb-mini-BT user manual

Mitsubishi FX3U-20SSC-H user manual

Mitsubishi

Mitsubishi FX3U-20SSC-H user manual

Autoscript WC-IP user guide

Autoscript

Autoscript WC-IP user guide

Basler AVC63-4 Instructions for use

Basler

Basler AVC63-4 Instructions for use

Ametek ZF2 Series Instruction, Operation and Maintenance Manual

Ametek

Ametek ZF2 Series Instruction, Operation and Maintenance Manual

iNels JA3-018M quick start guide

iNels

iNels JA3-018M quick start guide

Dwyer Instruments DCT1010DC Installation and operating instructions

Dwyer Instruments

Dwyer Instruments DCT1010DC Installation and operating instructions

Omnitronic DXO SERIES user manual

Omnitronic

Omnitronic DXO SERIES user manual

Troy-Bilt 49M2027P966 Operator's manual

Troy-Bilt

Troy-Bilt 49M2027P966 Operator's manual

GIESSE VARIA SLIM BASE Instruction and installation manual

GIESSE

GIESSE VARIA SLIM BASE Instruction and installation manual

Festo Controller CECC manual

Festo

Festo Controller CECC manual

Entron iPAK2 user guide

Entron

Entron iPAK2 user guide

Danfoss QT operating guide

Danfoss

Danfoss QT operating guide

Leroy-Somer DMV 2342 Addition to Manual

Leroy-Somer

Leroy-Somer DMV 2342 Addition to Manual

Omron NE1A-SCPU02 instruction manual

Omron

Omron NE1A-SCPU02 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.