Contents
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . .
3
1.
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
2.
Description of device
. . . . . . . . . . . . . . . . . . . .
10
2.1
Intended use for
VENTI
motion
/
VENTI
logic
.
10
2.2
Functional description
. . . . . . . . . . . . . . .
10
–
Provision of therapy pressure
–
Therapy modes
–
Other functions
3.
Hygiene treatment
. . . . . . . . . . . . . . . . . . . . .
11
3.1
Cleaning and disinfecting in use
. . . . . . . .
11
3.2
Cleaning and disinfecting on
repair
. . . . .
11
3.3
Cleaning and disinfecting
for a
patient change
. . . . . . . . . . . . . . . . . . .
11
3.4
Clean and disinfect humidifier during
use
. .
12
3.5
Clean and disinfect humidifier on
patient
change
. . . . . . . . . . . . . . . . . . . . . . . .
12
3.6
Clean and disinfect the
VENTI
power
. . . . .
12
3.7
Clean and disinfect the
VENTI-
O
2
. . . . . . .
12
4.
Test the device
. . . . . . . . . . . . . . . . . . . . . . . .
13
4.1
General
. . . . . . . . . . . . . . . . . . . . . . . .
13
4.2
Test equipment
. . . . . . . . . . . . . . . . . . .
13
4.3
Preparation for testing
. . . . . . . . . . . . . . .
13
–
Check power supply cable
–
Check housing
–
Connection to VENTI
support
4.4
Enter device data
. . . . . . . . . . . . . . . . .
14
4.5
Test temperature calibration and
calibration
status
. . . . . . . . . . . . . . . . . .
14
4.6
Test battery voltage
. . . . . . . . . . . . . . . .
15
4.7
Test interface with the
VENTI
click
. . . . . . .
15
4.8
Check target pressure values
5, 20 and 35
hPa
. . . . . . . . . . . . . . . . .
15
4.9
Test flow measurement
. . . . . . . . . . . . . .
16
4.10
Test leaktightness
. . . . . . . . . . . . . . . . .
17
4.11
Test clock function
. . . . . . . . . . . . . . . . .
17
4.12
Test the interface with the
VENTI-
O
2
. . . . .
18
4.13
Test interface with the
VENTI
power
. . . . .
18
4.14
Test noise
. . . . . . . . . . . . . . . . . . . . . .
19
4.15
Test all keys, the rotary knob and
115 V mode
. . . . . . . . . . . . . . . . . . . .
19
4.16
Test display incl. backlighting and
contrast, the
LEDs and the alarm
. . . . . . .
20
4.17
Test equipment and accessories
(system
components)
. . . . . . . . . . . . . . .
21
–
Check function of humidifier
–
Function check
VENTI-
O
2
4.18
Once tests are complete
. . . . . . . . . . . . .
22
5.
Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . .
23
5.1
Intervals
. . . . . . . . . . . . . . . . . . . . . . . .
23
5.2
Filter change
. . . . . . . . . . . . . . . . . . . . .
24
–
Coarse dust filter
–
Fine filter
–
Reset filter change indicator
–
Bacteria filter
5.3
Device cleaning
. . . . . . . . . . . . . . . . . .
25
5.4
Reset maintenance symbol
. . . . . . . . . . . .
26
5.5
Check the maintenance sticker
. . . . . . . . .
27
5.6
Disposal
. . . . . . . . . . . . . . . . . . . . . . .
27
6.
Malfunctions and rectification
. . . . . . . . . . . . . 28
6.1 General faults. . . . . . . . . . . . . . . . . . . . 28
6.2 Internal faults . . . . . . . . . . . . . . . . . . . . 29
– Fault output in clear text
– Coded error messages
7. Repairguide for VENTImotion/VENTIlogic . . . . 31
7.1 General . . . . . . . . . . . . . . . . . . . . . . . 31
7.2 Open device . . . . . . . . . . . . . . . . . . . . 31
7.3 Close the device. . . . . . . . . . . . . . . . . . 32
7.4 Replace mains supply unit. . . . . . . . . . . . 33
7.5 Replace power board . . . . . . . . . . . . . . 34
7.6 Replace box and filter holder. . . . . . . . . . 35
7.7 Replace fan . . . . . . . . . . . . . . . . . . . . . 37
7.8 Replace control board/display . . . . . . . . 39
7.9 Replace battery on control board . . . . . . . 42
7.10 Dismantle device outlet . . . . . . . . . . . . . 42
7.11 Replace encoder (dial) . . . . . . . . . . . . . 44
7.12 Replace fascia film . . . . . . . . . . . . . . . . 45
7.13 Replace bottom part of housing. . . . . . . . 46
7.14 Replace top part of housing . . . . . . . . . . 47
8. Spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.1 List of spare parts for
VENTImotion/VENTIlogic . . . . . . . . . . . . 48
8.2 Spare parts required for servicing. . . . . . . 51
9. Tools, test equipment and disinfectants . . . . . . 53
9.1 Tools . . . . . . . . . . . . . . . . . . . . . . . . . 53
9.2 Test equipment and fixtures . . . . . . . . . . . 53
9.3 Disinfectants. . . . . . . . . . . . . . . . . . . . . 54
10. Technical data . . . . . . . . . . . . . . . . . . . . . . . . 55
10.1 Diagram of pneumatic system . . . . . . . . . 57
10.2 Safety distances. . . . . . . . . . . . . . . . . . 57
11. Technical amendments . . . . . . . . . . . . . . . . . . 58
12. Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
12.1 Repair and service protocol . . . . . . . . . . 59
12.2 Test protocol . . . . . . . . . . . . . . . . . . . . 60