Xtreme V80 Series Guide

V80 Value Series Pure Sine Wave
Line Interacve UPS
700VA, 1000VA, 1500VA, 2000VA Models
User & Installaon Manual
www.xpcc.com | © 2022 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 7/6/22)

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 2
Uninterrupble Power Supply
Table of Contents
Important Safety Warning............................................................................3
Transportaon.................................................................................................................................3
Preparaon......................................................................................................................................3
Installaon.......................................................................................................................................3
Hardware Installaon......................................................................................................................3
Maintenance, Service, and Faults...................................................................................................4
Storage........................................................................................................5
Basic Operaon............................................................................................5
Front and Top Panel Descripon......................................................................................................5
LCD Indicators..................................................................................................................................6
Troubleshoong...........................................................................................7
Fault Reference Codes....................................................................................................................8
Specicaons...............................................................................................9
Shipping List................................................................................................9
Obtaining Service.......................................................................................10
Xtreme Power Conversion Limited Warranty..............................................11
Xtreme Power Conversion Load Protecon Policy.......................................12

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 3
Uninterrupble Power Supply
Important Safety Warning
This manual contains important safety instrucons. Please read and follow all instrucons carefully during installa-
on and operaon of the unit. Read this manual thoroughly before aempng to unpack, install, or operate your
UPS.
Transportaon
• Please transport the UPS system only in the original package to protect against shock and impact.
Preparaon
• Condensaon may occur if the UPS system is moved directly from cold to warm environment. The UPS
system must be absolutely dry before being installed. Please allow at least two hours for the UPS system
to acclimate the environment.
• Do not install the UPS system near water or in moist environments.
• Do not install the UPS system where it would be exposed to direct sunlight or near heater.
• Do not block venlaon holes in the UPS housing.
Installaon
How to determine the power requirements of your equipment
1. Ensure that the equipment plugged into the baery power-supplied outlets does not exceed the UPS
unit’s rated capacity. If rated unit capacies are exceeded, an overload condion may occur and
cause the UPS unit to shut down or the fuse blow.
2. There are many factors that can aect the amount of power that your computer system will require.
For opmal system performance keep the load below 80% of the unit’s rated capacity.
Hardware Installaon Guide
1. Your new UPS may be used immediately upon receipt. However, recharging the baery for at least 8
hours is recommended to ensure that the baery’s maximum charge capacity is achieved. Charge loss
may occur during shipping and storage. To recharge the baery, simply leave the unit plugged into an AC
outlet. The unit will charge in both the on and o posion.
2. With the UPS unit o and unplugged, connect the computer, monitor, and any externally powered
data storage device.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet
is protected by a fuse or circuit breaker and does not service equipment with large electrical demands.
• To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor area
free of conducve contaminants. (See the specicaons for the acceptable temperature and humidity
range.)
• To reduce the risk of overheang the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit
to direct sunlight or installing the unit near heat eming appliances such as space heaters or furnaces.
• Do not aach non-computer-related items, such as medical equipment, life-support equipment, micro-
wave ovens, or vacuum cleaners to UPS.
• Do not plug the UPS input into its own output.
• Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-
containing vessels on or near the unit.
• In the event of an emergency, press the OFF buon and disconnect the power cord from the AC power
supply to properly disable the UPS.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 4
Uninterrupble Power Supply
4. Depress the power switch to turn the unit on. The LCD indicator light will illuminate and the unit will
“beep”.
5. To maintain opmal baery charge, leave the UPS plugged into an AC outlet at all mes.
6. To store your UPS for an extended period, cover it and store with the baery fully charged. Recharge
the baery every three months to ensure baery life.
Maintenance, Service, and Faults
• The UPS system operates with hazardous voltages. Repairs may be carried out only by qualied mainte-
nance personnel.
• Cauon - risk of electric shock. Even aer the unit is disconnected from the mains (building wiring outlet),
components inside the UPS system are sll connected to the baery and electrically live and dangerous.
• Before carrying out any kind of service and/or maintenance, disconnect the baeries and verify that no
current is present and no hazardous voltage exists in the terminals of high capability capacitor such as
BUS-capacitors.
• To avoid electrical shock, turn o the unit and unplug it form the AC power source before servicing the
baery.
• Only persons are adequately familiar with baeries and with the required precauonary measures may
replace baeries and supervise operaons. Unauthorized persons must be kept well away from the bat-
teries.
• Cauon - risk of electric shock. The baery circuit is not isolated from the input voltage. Hazardous volt-
ages may occur between the baery terminals and the ground. Before touching, please verify that no
voltage is present!
• Baeries may cause electric shock and have a high short-circuit current. Please take the precauonary
measures specied below and any other measures necessary when working with baeries:
»Remove wristwatches, rings and other metal objects
»Use only tools with insulated grips and handles.
• When changing baeries, install the same number and same type of baeries.
• Do not aempt to dispose of baeries by burning them. This could cause baery explosion.
• Do not open or destroy baeries. Escaping electrolyte can cause injury to the skin and eyes. It may be
toxic.
• When replacing baeries, replace with the same type and number of baeries or baery packs.
• Do not dismantle the UPS system.
• A baery can present a risk of electrical shock and high short-circuit current. The following precauons
should be observed when working on baeries:
»Remove watches, rings, or other metal objects.
»Use tools with insulated handles.
»Wear rubber gloves and boots.
»Do not lay tools or metal parts on top of baeries.
»Disconnect charging source prior to connecng or disconnecng baery terminals.
»Determine if baery is inadvertently grounded. If inadvertently grounded, remove source from
ground. Contact with any part of a grounded baery can result in electrical shock. The likelihood
of such shock can be reduced if such grounds are removed during installaon and maintenance.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 5
Uninterrupble Power Supply
Storage
1. First turn o your UPS and disconnect its power cord from the wall outlet. Disconnect all cables con
nected the UPS to avoid baery drain.
2. The UPS should be stored in a cool dry locaon.
3. Make sure the baery is fully charged before the UPS is stored.
4. For extended storage in moderate climates, the baery should be charged for 12 hours every 3
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat it
every 2 months in high temperature locaons.
Basic Operaon
Front and Top Panel Descripon
1. Input Circuit Breaker
The circuit breaker provides opmal overload protecon.
2. AC Inlet
Connect to ulity power through the input power cord.
(IEC320 C14 for 700VA/1000VA/1500VA, IEC 320 C20 for 2000VA)
3. AC outlet
The UPS provides outlets for connected equipment to insure temporary uninterrupted operaon during
a power failure and against surges and spikes.
4. USB Port
This port allows connecon and communicaon from the USB port on the computer to the UPS unit.
5. Power On/O Buon
Press the power Buon to turn the UPS ON or OFF.
6. Seng Buon
The audible alarm can be turned o/on by pressing this buon 3s.
7. LCD Display
The LCD will display the UPS status.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 6
Uninterrupble Power Supply
Denions for Illuminated LCD Indicators
LCD Indicators
AC INPUT(Voltage)
V
OUTPUT(Voltage)
V
Inial
Line mode
Bat-mode
Baery capacity
Load capacity
Fault
Sound disable
(Press the seng key 3s to disable and enable the buzzer sound)

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 7
Uninterrupble Power Supply
Troubleshoong
Problem Possible Causes Remedy
Abnormal
Mains normal but not
works in AC mode
1. AC Input missing 1. Check AC input connecon.
2. Input Breaker is tripped 2. Unplug the power cord of the UPS then
press the circuit breaker knob.
The UPS will not turn
on.
The on/o Buon is designed to prevent
damage by rapidly turning it o and on.
Turn the UPS o. Wait 10 seconds and
then turn the UPS on.
The unit is not connected to an AC outlet. The unit must be connected to a 100-
127V 50/60Hz outlet.
The baery is worn out. Contact technical support.
Mechanical problem.
Outlets do not provide
power to equipment
Circuit breaker is tripped due to overload
Turn the UPS o and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then press the
circuit breaker knob
Baeries are discharged Allow the unit to recharge for at least 4
hours.
Unit has been damaged by a surge or spike. Contact technical support.
Alarm code A51
Site Fail:
Line and neutral conductors of UPS Input
are reversed or the Ground is disconnect-
ed.
Check the input plug and socket.
Alarm code A56
Baery low:
Baery capacity is low, UPS will turn o
soon
1. Shut o non-essenal equipment.
2. Save your data and turn o the com-
puter.
Alarm code A64
Overload:
Your equipment requires more power than
the UPS can provide.
1. Shut o non-essenal equipment.
Alarm code A68 Over Temperature 1. Shut o non-essenal equipment.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 8
Uninterrupble Power Supply
Fault Codes
Fault
Fault code E09 Output Short :
Output circuit short.
1. Shut down the UPS
2. Your aached equipment may have
problems, please remove them and check
again.
Fault code E14
Overload:
Your equipment requires more power than
the UPS can provide.
It will shutdown.
Shut o non-essenal equipment. If this
solves the overload problem, the UPS will
transfer to normal operaon.
Fault code E18 Fan fail :
Fan has been damaged.
1.Shut down the UPS
2.Replace the fan
Fault code E19 Over Temperature
1. Shut down the UPS. Restart the UPS
to Check the fan for operaon and if the
venlaon hole has been covered
2. Contact technical support for repair.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 9
Uninterrupble Power Supply
Specicaons
Shipping List
1. Line cord
2. Rack Ear
3. User manual
4. USB cable
MODEL NUMBER V80-700 V80-1000 V80-1500 V80-2000
CAPACITY Power rang 700VA (420W) 1000VA (600W) 1500VA (900W) 2000VA (1200W)
INPUT Voltage nominal 120VAC
Voltage range 82-148VAC
Frequency 50/60Hz auto sensing
OUTPUT Voltage 120VAC
Waveform Pure sine wave
Transfer me (typical) 2–6ms
Eciency Up to 96% ECO mode, 93% buck and boost mode
Harmonic distoron 2% @ 100% linear load; 5% @ 100% non-linear load
BATTERY Baery type Sealed, maintenance-free lead acid
Baery quanty & size (1) 12V 9AH (2) 12V 7AH (2) 12V 9AH (2) 12V 9AH
Charging current 1A max
Typical recharge 4 hours to 90%
PHYSICAL Dimensions (W x D x H) 17.2" x 16.1" x 3.5"
Weight 24 lbs 27.3 lbs 36.5 lbs 36.5 lbs
Line cord (removable) 6, 5-15P to C13 6, 5-20P to C19
Receptacles (8) NEMA 5–15R
ENVIRONMENT Operang temperature 32–104°F (0–40°C)
Audible noise < 40dBA < 45dBA
Altude 11,500 above sea level
APPROVALS cTUVus, RoHs
WARRANTY 3 years electronics, 3 years baery warranty (USA and Canada)
COMMUNICATIONS INTERFACE USB
INCLUDED IN BOX Line cord, tower pedestals, user manual, USB cable
AVAILABLE OPTIONS 5 year extended warranty, bypass distribuon (XBDM), power distribuon (XPDU), 4-post rail
kit, 2-post shelf kit, wall mount bracket

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 10
Uninterrupble Power Supply
Obtaining Service
If the UPS requires Service:
1. Use the TROUBLESHOOTING secon in this manual to eliminate obvious causes.
2. Verify there are no circuit breakers tripped.
3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme
Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at
[email protected]. Please have the following informaon available BEFORE calling the Technical Support
Department:
• Your name and address.
• The serial number of the unit.
• Where and when the unit was purchased.
• All of the model informaon about your UPS.
• Any informaon on the failure, including LED’s that may or may not be illuminated.
• A descripon of the protected equipment, including model numbers if possible.
• A technician will ask you for the above informaon and, if possible, help solve your problem over the
phone. In the event that the unit requires factory service, the technician will issue you a Return Mate-
rial Authorizaon number (RMA).
If you are returning the UPS to Xtreme Power for service, please follow these procedures:
1. Pack the UPS in its original packaging. If the original packaging is no longer available, ask the Technical Sup-
port Technician about obtaining a replacement set of packaging material. It is important to pack the UPS
properly in order to avoid damage in transit. Never use Styrofoam beads for a packing material.
2. Include a leer with your name, address, dayme phone number, RMA number, a copy of your original
sales receipt, and a brief descripon of the problem.
3. Mark the RMA number on the outside of all packages. Xtreme Power cannot accept any package without
the RMA number marked on the outside of the boxes.
4. Return the UPS by insured, prepaid carrier to the address provided by the Technician.
5. Refer to the Warranty statements in this manual for addional details on what is covered.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 11
Uninterrupble Power Supply
Xtreme Power Conversion Limited Warranty
Xtreme Power Conversion (XPC) Corporaon warrants Xtreme Power Conversion equipment, when properly ap-
plied and operated within specied condions, against faulty materials or workmanship for a period of three years
for V80-Series products from the date of purchase. XPC Corporaon warrants internal baeries for a period of
three years from the date of purchase. For equipment sites within the United States and Canada, this warranty
covers repair or replacement, at the sole discreon of XPC Corporaon. The customer is responsible for the costs
of shipping the defecve product to XPC Corporaon. XPC Corporaon will pay for ground shipment of the re-
paired or replacement product. This warranty applies only to the original purchaser.
If equipment provided by XPC Corporaon is found to be Dead-on-Arrival (DOA), XPC Corporaon will be respon-
sible for the costs of shipping product to and returning equipment from the customer in a mely manner as agreed
to with the customer, once the customer has requested and received a Return Material Authorizaon (RMA)
number. DOA equipment is dened as equipment that does not properly funcon according to user documenta-
on when inially received and connected in conjuncon with proper procedures as shown in the user documen-
taon or via support provided by XPC Corporaon personnel or authorized agents.
This warranty shall be void if (a) the equipment is repaired or modied by anyone other than XPC Corporaon or
a XPC Corporaon approved third party; (b) the equipment is damaged by the customer, is improperly used or
stored, is subjected to an adverse operang environment, or is operated outside the limits of its electrical speci-
caons; or (c) the equipment has been used or stored in a manner contrary to the equipment’s operang manual,
intended use or other wrien instrucons. Any technical advice furnished by XPC Corporaon or a XPC Corpora-
on authorized representave before or aer delivery with regard to the use or applicaon of Xtreme Power Con-
version equipment is furnished on the basis that it represents XPC Corporaons best judgment under the situaon
and circumstances, but it is used at the recipient’s sole risk.
EXCEPT AS STATED ABOVE, XPC Corporaon DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
EXCEPT AS STATED ABOVE, IN NO EVENT WILL XPC Corporaon BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCI-
DENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme Power Conversion EQUIPMENT,
including but not limited to, any costs, lost prots or revenue, loss of equipment, loss of use of equipment, loss
of soware, loss of data, cost of substutes, or claims by third pares. Purchaser’s sole and exclusive remedy for
breach of any warranty, expressed or implied, concerning Xtreme Power Conversion equipment, and the only
obligaon of XPC Corporaon under this warranty, shall be the repair or replacement of defecve equipment,
components, or parts; or, at XPC Corporaons sole discreon, refund of the purchase price or substuon of an
equivalent replacement product.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 12
Uninterrupble Power Supply
Xtreme Power Conversion Load Protecon Policy
THIS POLICY IS NOT A WARRANTY. REFER TO THE XPC CORPORATION, INC. LIMITED WARRANTY FOR
INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC PRODUCT. THE LIMITATIONS AND CONDITIONS
CONTAINED IN THIS POLICY DO NOT AFFECT THE TERMS OF THE XPC LIMITED WARRANTY.
Denions:
1. “Product” means a Standard 120, 208, or 240 Volt power protecon device that is used in the United
States and Canada. This policy does not include custom manufactured products.
2. “Power Disturbance” means an AC power line transient (telephone line or Local Area Network, if appli-
cable), spike or surge.
3. “Connected Equipment” properly connected electronic equipment
4. “Fair Market Value” of damaged Connected Equipment as determined by XPC shall be the lower of (a) the
average price the same or similar items are being sold for on eBay, (b) the price list of Orion Blue Book (or
if such price list is no longer published, a published or announced price list reasonably selected by XPC),
(c) the lowest price the same or similar items can be purchased for in the United States or (d) the total
amount of all payment(s) you have or are entled to receive from insurance, other warranes, extended
warranes, a legal liability claim or from other sources or persons for the damaged Connected Equipment.
5. “Purchaser” means the person or enty that originally purchased the Product from an authorized reseller
or distributor of XPC Products.
The Purchaser of this Product is protected, for the term of the XPC Limited Warranty, against certain losses caused
by a Power Disturbance for properly connected electronic equipment (referred to as the "Connected Equipment")
subject to certain terms and condions provided below.
This policy applies only to the original purchaser of the Product. If the Product is transferred or sold to another
person or enty, this policy is void.
Load Protecon Policy Dollar and Period Limits
For purchasers that meet the qualicaons and condions set forth in this policy, XPC will provide reimbursement
(cost of repair or fair market value as determined by XPC) during the period limits and up to the dollar limits stated
as follows:
PRODUCT DOLLAR LIMIT PERIOD OF COVERAGE
V80 25,000 Term of XPC Limited Warranty
XST 25,000 Term of XPC Limited Warranty
S70 25,000 Term of XPC Limited Warranty
XPRT 6kVA & 10kVA 50,000 Term of XPC Limited Warranty
P80, P80g 50,000 Term of XPC Limited Warranty
P90, P90L, P90g, P90Lg 50,000 Term of XPC Limited Warranty
T90, T91 50,000 Term of XPC Limited Warranty
TX90, TX90i 50,000 Term of XPC Limited Warranty
This Load Protecon Policy is not deemed "rst dollar" coverage. XPC’s obligaon is reduced by any amounts that
the Purchaser is entled to recover, from other sources regarding the Connected Equipment, including, but not
limited to, insurance, other warranty, extended warranty, or legal liability, regardless of whether or not the Pur-
chaser makes a claim for recovery.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 13
Uninterrupble Power Supply
Eligibility for Coverage Under the Load Protecon Policy
1. The Product must be registered on the XPC website, www.xpcc.com, within 10 days of purchase. All re-
quired informaon must be provided, and Purchaser should retain a copy for Purchaser’s records. When
registering on the website, Purchaser must list all connected equipment that is directly connected to the
product. Only those devices registered in that manner will be covered.
2. All Connected Equipment must be UL or CSA approved.
3. The Product must be plugged into a properly wired and grounded outlet. Use of input surge devices, ex-
tension cords, adapters, ground wires, or electrical connecons not manufactured by XPC voids the XPC
Load Protecon Policy. No other surge protecon device may be connected to the output sockets of the
Product. The installaon must comply with all applicable electrical and safety codes set forth pursuant to
the NEC.
4. The Product must have undeniable physical evidence of a Power Disturbance that directly and proximately
caused the damage;
5. The Connected Equipment must have been damaged by a Power Disturbance on a properly installed,
grounded, and Naonal Electric Code, ("NEC"), code-compliant 120, 208, 240 Volt AC power line in the
United States or Canada, by a Power Disturbance on standard telephone land line or PBX telephone equip-
ment line that is properly installed and connected to an RJ11 port on the Product; or by a Power Distur-
bance on a standard Local Area Network connecon that is properly installed and connected to an RJ45
port on the Product and (d) is directly plugged into, and properly connected to, the Product in its original
condion which was properly operated when a Power Disturbance passed through the Product and (i)
exhausts the protecon capacity of the Product or (ii) damages the Product.
6. The Load Protecon Policy does not apply if the Product has been operated in a failure mode or not in
compliance with XPC operang instrucons in the Product user's manual, or if the Connected Equipment
has not been operated in compliance with the instrucons and manuals of its manufacturer/vendor.
7. This policy is null and void if, XPC determines, in its sole discreon, that the Product has been tampered
with or altered in any way.
What is Not Covered Under the Load Protecon Policy:
The following damage is not covered by this Policy:
1. Restoraon of lost data and reinstallaon of soware.
2. Damage from a cause other than AC power-line transients, except for damage due to telephone line, Local
Area Network, or CATV transients, which is covered only if the Product oers such protecon.
3. DAMAGE CAUSED BY FAILURE TO PROVIDE A SUITABLE INSTALLATION ENVIRONMENT FOR THE PRODUCT
(INCLUDING, BUT NOT LIMITED TO, LACK OF A PROPER SAFETY GROUND).
4. Damage caused by the use of the Product for purposes other than those for which it was designed.
5. Damage caused by accidents, or natural disasters, including but not limited to, re, ood, and wind.
6. Damage caused by abuse, misuse, alteraon, modicaon, or negligence.
7. Any labor costs or travel, room and board expenses associated with the repair and/or restoraon of lost or
damaged hardware, soware or data.
EXCEPT AS EXPRESSLY PROVIDED IN THIS POLICY, XPC SHALL NOT BE LIABLE FOR ANY DAMAGES WHATSOEVER,
INCLUDING, BUT NOT LIMITED TO, DIRECT, INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR MULTIPLE
DAMAGES ARISING OUT OF THE USE OF THE PRODUCT OR DAMAGE TO THE CONNECTED EQUIPMENT, REGARD-
LESS OF THE LEGAL THEORY ON WHICH SUCH CLAIM IS BASED, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGE. SUCH DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, LOSS OF PROFITS, LOSS OF SAVINGS OR REV-
ENUE, LOSS OF USE OF THE PRODUCT OR THE CONNECTED EQUIPMENT OR ANY ASSOCIATED EQUIPMENT, LOSS
OF SOFTWARE, COST OF CAPITAL, COST OF ANY SUBSTITUTE EQUIPMENT, FACILITIES OR SERVICES, DOWNTIME,
THE CLAIMS OF THIRD PARTIES, INCLUDING CUSTOMERS, AND INJURY TO PROPERTY.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 14
Uninterrupble Power Supply
Subming a Load Protecon Policy Claim:
1. Any claim under the Load Protecon Policy must be made within 10 days of the date of alleged damage to the
Connected Equipment.
2. Call the XPC technical support department at 1-800- 582-4524 and obtain a Load Protecon Policy Returned
Material Authorizaon (RMA) number. Have informaon on all applicable insurance or other resources of re-
covery/payment that is available to the Purchaser and the name of the power ulity supplier for the locaon
of the Connected Equipment. XPC will forward to the Purchaser a Load Protecon Policy claims form, which
must be completed and led with XPC within 30 days.
• Mark the Load Protecon Policy RMA number on the Product the Purchaser is returning.
• Pack the Product in its original packaging or similar packing materials if the original packaging has
been discarded. Enclose the completed Load Protecon Policy claim form and a copy of the Purchas-
er’s original sales receipt for the Product in the box.
• Mark the RMA number clearly on the outside of the box.
• Ship the Product (one-way shipping charges paid by the Purchaser) to:
XPC Corporaon
230 Yuma Street
Denver, CO 80223
An: LPP RMA#
3. XPC will evaluate the Product to determine its level of funconality, and will examine the Product for evidence
of damage from a Power Disturbance.
• If XPCs' evaluaon provides no evidence of damage from a Power Disturbance, XPC will send to the
Purchaser (i) a report summarizing the tests performed and (ii) a rejecon of claim noce.
• If the Product shows evidence of damage from a Power Disturbance, XPC will request that all Con-
nected Equipment for which a Load Protecon Policy claim has been submied, be sent for evaluaon
to either XPC or an authorized service center. If it is determined that the Connected Equipment has
been damaged by a Power Disturbance, XPC will, in its sole discreon, issue payment to the Purchaser
for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged
Connected Equipment, up to the dollar limits stated above. XPC reserves the right to require the
Purchaser to transfer tle and deliver the Connected Equipment to XPC if it chooses to reimburse the
Purchaser for the fair market value of the Connected Equipment. XPCs' maximum liability shall be
reduced to reect all such other payments or sources of recovery, whether applied for or not.
4. If XPC issues payment to the Purchaser to have the Connected Equipment repaired, the repair must be per-
formed at a service center that is authorized by the manufacturer of the Connected Equipment. XPC reserves
the right to contact the authorized service center directly to discuss repair costs and damage to the Connected
Equipment to determine if it was caused by a Power Disturbance and the right to request that the service
center forward the Connected Equipment or components of the Connected Equipment to XPC for inspecon
5. Unless modied in wring signed by an ocer of XPC and the Purchaser, the terms of this policy are the com-
plete and exclusive agreement between the pares, superseding all prior agreements, oral or wrien, and all
other communicaons between the pares relang to the subject maer of this agreement. No employee of
XPC or any other party is authorized to make any representaons beyond those made in this agreement con-
cerning the Load Protecon Policy.
XPC Corporaon
230 Yuma Street
Denver, CO 80223
1.800.582.4524
This manual suits for next models
4
Table of contents
Other Xtreme UPS manuals

Xtreme
Xtreme 2000VA Operating manual

Xtreme
Xtreme E91 Guide

Xtreme
Xtreme C60-800 Guide

Xtreme
Xtreme NXTI 3P-1P User manual

Xtreme
Xtreme P90-1000 Troubleshooting guide

Xtreme
Xtreme T90 Online 700VA Guide

Xtreme
Xtreme 500VA Guide

Xtreme
Xtreme TX90 Guide

Xtreme
Xtreme 1000VA Guide

Xtreme
Xtreme 20kVA Operating manual
Popular UPS manuals by other brands

Tripp Lite
Tripp Lite SMART1500CRMXL Specification sheet

Tripp Lite
Tripp Lite SmartPro Rackmount SMX1000RT2U owner's manual

MaxPower
MaxPower T Series user manual

Delta
Delta VX 600VA Installation & operation guide

Tripp Lite
Tripp Lite SMART1000LCDTAA quick guide

PowerWalker
PowerWalker VFI 1000RM user manual