manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Yale
  6. •
  7. Door Opening System
  8. •
  9. Yale Tri-Pack 51 User manual

Yale Tri-Pack 51 User manual

3/16" Pilot hole
required
#7
1/4-20
Spring Power Adjustment Screw
51(BF) Series Only
"BC" Valve
Pinion Cap
Closer
Size
Stamp "L"Valve "S"Valve
Standard Components Optional Components
4
Closer Body
Cover
Sleeve Nut and Bolt
Thru Bolt and Grommet Nut
Drill 9/32 thru from Closer Side
3/8 Drill other side
Drill
3/8 Drill other Side
9/32 thru from Closer Side
(Optional)
(2)
Metal Wood
Top Jamb
Installation
See Page 5
289A Soffit Plate
Used with Parallel
Arm Closers Only
Soffit Plate
Regular Arm/Top
Jamb Shoe Main Arm
Connecting Rod Forearm
Screw Arm Slide
Arm Assembly
214
Plate
"DL" suffix (Delayed Action) is an optional
feature. A separate sheet is supplied
showing closer adjustments.
NOTE: For special applications a separate
door and frame preparation template is
packed with these instructions. Use this
instruction sheet for installation sequence
and closer adjustments only.
Doors should be hung on ball bearing or
anti-friction hinges.
A separate door stop is recommended.
Door and frame must be properly
reinforced.
Adjust closing time speed between 3 and 7
seconds from 90° to 0°.
These door closers should NOT be
installed on the exposed side (weather
side) of exterior doors.
Right Hand Door - RH
Left Hand Reverse - LHR
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - RH
Left Hand Reverse - LHR
Right Hand Door - RH
Left Hand Reverse - LHR
Regular Arm
Installation
See Page 2
Left Hand Door - LH
Right Hand Reverse - RHR
Left Hand Door - LH
Right Hand Reverse - RHR
Top Jamb
Installation
See Page 5
Regular Arm
Installation
See Page 2
Parallel Arm
Installation
See Pages
3 & 4
Parallel Arm
Installation
See Pages
3 & 4
Machine Screws
#7 Drill, 1/4-20 Tap
Self Drilling Screws
Wood and Metal
For Wood drill 3/16 hole
CAUTION
CAUTION
An Incorrectly installed or improperly adjusted
door closer can cause property damage or
personal injury. These installation instructions
should be followed to avoid the possibility of
misapplication or misadjustment.
Installation Instructions
80-9350-2502-010 (05-12)
Non Hold Open Models
Sized
(Sizes 2,3,4,5,6)
52BC
53BC
54BC
55BC
56BC
Adjustable
(Sizes 3 thru 6)
51
(Sizes 1 thru 4)
51BF
Non Handed Door Closer
Tri-Pack 50 Series
Weaker
-
Stronger
+
3
2
7
1
3
4
Non Hold Open Door Closers — Regular Arm
5
Latch
Sweep
Parts
6
Backcheck
6
(152)
1-3/4
(44)
1-1/4
(32)
3/4
(19) 9-1/16
(230)
7/8
(22)
A
80-9350-2502-010 (05-12)
Opening
To 100°
101° to 120°
121° to 180°
*
7
(178)
6
(152)
3-1/2
(89)
Dimension "A"
Door/Wall/Hardware/Jamb
*
conditions permitting
Right Hand Shown
BC
LS
L
S
51(BF) Only
Spring Power Adjust
(If Necessary)
AB
F
90°
E
DInches
(mm)
— 2 —
P
A
(2)
or
50 Series
G
Pinion Cap
or Optional Cover
Caution:
Don't completely
close valve
Optional
Cover
C
L
Y
S
Z
R
LS
Stronger
+
Weaker
-
Slower
-
Faster
+
Faster
+
Slower
-
Stronger
+
Weaker
-
Optional
214
Plate
Parts
Right Hand Shown
2
1
80-9350-2502-010 (05-12)
50 Series Non Hold Open Door Closers — Parallel Arm
34
Holes for 214
Plate only
Door
Opening
To 100°
101° to 130°
131° to 180°
*
A
9-1/4
(235)
7-3/4
(197)
5-3/4
(146)
B
7-5/8
(194)
6-1/8
(156)
4-1/8
(105)
C
8-5/8
(219)
7-1/8
(181)
5-1/8
(130)
19.1
2-3/4
(70) 3/8
(10)
1/2
(13)
7/16
(11)
2
(50)
A
1-1/2
(38)
7
(178) 4
(102)
2-1/8
(54) 3-1/4
(83)
1/2
(13)
3/4
(19)
9-1/16
(230) C
L
C
B
Top of
Door
Door/Wall/Hardware/Jamb
*
conditions permitting
Inches
(mm)
5
— 3 —
S
L
Place Arm on
Spindle
R
o
t
a
t
e
Remove Arm
from Spindle
Close Valves
LS
Latch
Sweep
Optional
Cover
See Step 6 on Page 4
Frame
Slower
-
Slower
-
13 14
12
80-9350-2502-010 (05-12)
50 Series Non Hold Open Door Closers — Parallel Arm
11
Latch
Sweep
Backcheck
68
7
910
Spring Power Adjust
51(BF) only
(If necessary)
PA
BC
S
L
S
L
1-1/2
(38)
— 4 —
or
(2)
Assemble Arm
Arm Screw
Open Valves
Caution:
Don't completely
close valve
Pinion Cap
or Optional Cover
L
Y
S
Z
R
L
Y
S
Z
R
Left Hand
Door
Right Hand
Door
or
B
A
Flat
Flat
Slower
-
Faster
+
Weaker
-
Stronger
+
Stronger
+
Weaker
-
Slower
-
Faster
+
Caution:
Do Not Back
Valve Out
Completely
(2)
6
1
3
2
7
5
19.1
4
50 Series Non Hold Open Door Closers — Top Jamb Arm
Latch
Sweep
Backcheck
9-1/16
(230) 3/4
(19)
1/2
(13)
6
(152)
1-1/2
(38)
1-3/4
(44)
C
L
A
80-9350-2502-010 (05-12)
Opening
To 100°
101° to 120°
121° to 180°
*
7-1/2
(191)
6
(152)
3-1/2
(89)
Dimension "A"
Door/Wall/Hardware/Jamb
*
conditions permitting
Right Hand Shown
BC
LS
L
S
51(BF) Only
Spring Power Adjust
(If Necessary)
90°
Top of
Door
Inches
(mm)
— 5 —
D
B
AE
F
P
A
G
Parts
Caution:
Don't completely
close valve
A longer connecting
rod is required
for reveals greater
than 3" (76)
or
Pinion Cap
or Optional Cover
Optional
Cover
Reveal
C
L
Y
S
Z
R
Stronger
+
Weaker
-
Slower
-
Faster
+
Faster
+
Slower
-
Stronger
+
Weaker
-
Backcheck
BC
Sweep
LS
Latch
L
S
— 6 —
To identify your model: Arm Placement in Shoe
50 Series Adjustments
CLOSED
70°
10°
80-9350-2502-010 (05-12)
Spring Power Adjust
51 (BF) only
PA
Adjustment Chart
EXTERIOR
EXTERIOR
INTERIOR
INTERIOR
Regular Arm
Top Jamb
Regular Arm
Top Jamb
Regular Arm
Top Jamb
Regular Arm
Top Jamb
Parallel Arm
Parallel Arm
Parallel Arm
Parallel Arm
FULL 360° TURNS OF
3/16 POWER ADJUSTMENT
WRENCH
FULL 360° TURNS OF
3/16 POWER
ADJUSTMENT WRENCH
51BF
51
DOOR
TYPE
OF
INST. *34”
(0.85M)
36”
(0.90M)
40”
(1.00M)
44”
(1.10M)
48”
(1.20M)
11233
2 2 345
56**8
**8 912
246911
3 5 710 13
35710 13
5710 14 16
NOT
RECOMMENDED
USE 51
18 FULL (360°) TURNS MAXIMUM AVAILABLE
*
MAXIMUM DOOR SIZE
Number of Turns Required
Date
Code
or
or
7-1/2 % Stronger
7-1/2 % Weaker
(Use 3/16" Hex Wrench for this Adjustment)
(Use 1/8" Hex Wrench for these Adjustments)
Stronger
+
Weaker
-
Slower
-
Faster
+
Faster
+
Slower
-
Stronger
+
Weaker
-
3-6
BE
Size
Code
+
-
An ASSA ABLOY Group brand
3000 Highway 74 East • Monroe, NC 28112
Tel: (800)-438-1951 • Fax: (800)-338-0965
www.yalecommercial.com
Yale ® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2001, 2012, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
AS SHIPPED FROM FACTORY
**
5= 5 5B C
4=54BC
3=53BC
2=5 2BC
6= 5 6B C
3 - 6=5 1
1- 4=51BF

This manual suits for next models

1

Other Yale Door Opening System manuals

Yale PR50 User manual

Yale

Yale PR50 User manual

Yale Tri-Pack 50 Series User manual

Yale

Yale Tri-Pack 50 Series User manual

Yale 3040 User manual

Yale

Yale 3040 User manual

Yale YDC201 User manual

Yale

Yale YDC201 User manual

Yale 150 Series User manual

Yale

Yale 150 Series User manual

Yale Delayed Egress 7100 Series User manual

Yale

Yale Delayed Egress 7100 Series User manual

Yale 7000 Series User manual

Yale

Yale 7000 Series User manual

Yale 2100 Series User manual

Yale

Yale 2100 Series User manual

Yale Lockmaster PED1000 User manual

Yale

Yale Lockmaster PED1000 User manual

Yale YM Series User manual

Yale

Yale YM Series User manual

Yale 50 Series User manual

Yale

Yale 50 Series User manual

Yale UNI Series User manual

Yale

Yale UNI Series User manual

Yale 3000 Series User manual

Yale

Yale 3000 Series User manual

Yale UniTrol UNI-50BC Series User manual

Yale

Yale UniTrol UNI-50BC Series User manual

Yale PR3301 User manual

Yale

Yale PR3301 User manual

Yale UNOplus 3000 User manual

Yale

Yale UNOplus 3000 User manual

Yale YM Series User manual

Yale

Yale YM Series User manual

Yale 7110 User manual

Yale

Yale 7110 User manual

Yale 3000 Series User manual

Yale

Yale 3000 Series User manual

Yale Power Track Series User manual

Yale

Yale Power Track Series User manual

Yale 6116 Series User manual

Yale

Yale 6116 Series User manual

Yale UNI-TJ50BC Series User manual

Yale

Yale UNI-TJ50BC Series User manual

Popular Door Opening System manuals by other brands

Mobeye Call-Key MCK100 installation manual

Mobeye

Mobeye Call-Key MCK100 installation manual

SALICE Lapis Assembly instructions

SALICE

SALICE Lapis Assembly instructions

Cal-Royal N-F77CVR Installation instruction

Cal-Royal

Cal-Royal N-F77CVR Installation instruction

Scrigno OPEN1000 Assembly manual

Scrigno

Scrigno OPEN1000 Assembly manual

BFT WIND RMB 130B 200 installation manual

BFT

BFT WIND RMB 130B 200 installation manual

Alecto ADI-250 user manual

Alecto

Alecto ADI-250 user manual

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Besam

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Assa Abloy SARGENT 1431 Series instructions

Assa Abloy

Assa Abloy SARGENT 1431 Series instructions

GAL MOVFR Quick setup

GAL

GAL MOVFR Quick setup

Häfele Finetta T 70 VF manual

Häfele

Häfele Finetta T 70 VF manual

AGS D-PL Instructions for fitting, operating and maintenance

AGS

AGS D-PL Instructions for fitting, operating and maintenance

Stanley MA900ñ Installation and owner's manual

Stanley

Stanley MA900ñ Installation and owner's manual

WITTUR Hydra Plus UD300 Instruction handbook

WITTUR

WITTUR Hydra Plus UD300 Instruction handbook

Alutech TR-3019-230E-ICU Assembly and operation manual

Alutech

Alutech TR-3019-230E-ICU Assembly and operation manual

Pamex KT-INP35 Installation instruction

Pamex

Pamex KT-INP35 Installation instruction

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

MPC

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

Chamberlain T user guide

Chamberlain

Chamberlain T user guide

Dorma MUTO COMFORT M DORMOTION 50 Mounting instruction

Dorma

Dorma MUTO COMFORT M DORMOTION 50 Mounting instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.