VER. 003_20.05.2011
4-CHANNEL RADIO TRANSMITTER RNP-01
MANUAL INSTRUCTION
APPEARANCE
TECHNICAL DATA
RNP-01
Input (supply) terminals: L, N
Input rated voltage: 230 V AC
Input voltage tolerance: -15 ÷ +10 %
Nominal frequency: 50 / 60 Hz
Nominal power consumption: 0,22 W
Release terminals: IN1, IN2, IN3, IN4
Number of channels: 4
Transmission: radio 868,32 MHz
Transmission way: unidirectional
Coding: addressing transmission
Range: up to 200 m in the open area
Optic signalling of transmission: LED red diode
Ambient temperature range: -10 ÷ +55 oC
Number of terminal clamps: 6
Section of connecting cables: up to 2,5 mm2
Operating position: free
Casing mounting: installation cable box Ø 60 mm
Casing protection degree: IP20 (EN 60529)
Protection level: II
Overvoltage category: II
Pollution degree: 2
Surge voltage: 1 kV (EN 61000-4-5)
Dimensions: 47,5 x 47,5 x 20 mm
Weight: 0,031 kg
Reference standard: ETSI EN 300 220-1, ETSI EN 300 220-2,
EN 60950, EN 61000
The device is designed for
single-phase installation and
must be installed in accordance
with standards valid in a particu-
lar country. The device should
be connected according to the
details included in this operat-
ing manual. Installation, connection and control
should be carried out by a qualied electrician
staff, who act in accordance with the service
manual and the device functions. Disassembling
of the device is equal with a loss of guarantee and
can cause electric shock. Before installation make
sure the connection cables are not under voltage.
The cruciform head screwdriver 3,5 mm should
be used to instal the device. Improper transport,
storage, and use of the device inuence its wrong
functioning. It is not advisable to instal the device
in the following cases: if any device part is miss-
ing or the device is damaged or deformed. In case
of improper functioning of the device contact the
producer.
CAUTION!
FEATURES
DESCRIPTION
● radio transmitter mounted in Ø 60 mm
junction box,
● remote control of EXTA FREE system
receivers,
● possibility of connection to a traditional
household switch,
● low power consumption, adapted to
constant operation,
● possibility of independent control of
four receivers,
● wide range of operation (up to 200 m),
● possibility of simultaneous switching
on/switching off any number of EXTA
FREE system receivers,
● possibility of increasing operation ran-
ge by means of RTN-01 retransmitter.
Radio transmitter RNP-01 realises
remote control function of devices.
It is mounted in a junction box and under
the existing switch (monostable push-
buttons). This solution is very useful and
results in easy installation of EXTA FREE
system without interference in existing
wiring system. There is a possibility of us-
ing electroinstallation equipment of any
manufacturer (no design limit).
The symbol means selective
collecting of electrical and electronic
equipment. It is forbidden to put
the used equipment together
with other waste.
Optic signalling of receiver’s operation
Input (supply) terminals (L, N)
Release terminals (IN1, IN2, IN3, IN4)
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
VER. 003_20.05.2011
CONNECTION MOUNTING, CONNECTION
APPLICATION
1. Disconnect power supply by the phase fuse, the circuit-
breaker or the switch-disconnector combined to the
proper circuit.
2. Check if there is no voltage on connection cables
by means of a special measure equipment.
3. Connect the cables with terminals in accordance with
the installing diagram.
4. Install RNP-01 device in installation cable box.
5. Switch on the power supply from the mains.
The device is ready to operate after correct mount-
ing and connection. Releasing the system by a mon-
ostable push-button connected to one of four release
terminals (IN1-IN4) causes the RNP-01 device to send
a radio control signal added to this input (channel).
LED red diode signals the transmission is on. Device
programming procedure (adding a transmitter to re-
ceiver’s memory) is described in manual instructions
of particular EXTA FREE receivers.
4-channel radio transmitter RNP-01
controls operation of radio ush dimmer
RDP-01 (switch on/switch or light bright-
ening/dimming) or remote control socket
RWG-01 (switch on/switch off). The re-
ceivers can be controlled by 8-channel
P-256/8 remote control. RNP-01 device
can be mounted under the existing light-
ing switch (required power supply: 230V
AC – L and N wires).
COOPERATION AND OPERATING RANGE
Symbol: ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m
RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m
RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
*- 1-channel transmitters do not cooperate with roller blind controllers.
CAUTION: The given range concerns open area - an ideal condition without any natural or articial obstacles. If there are some obstacles between a transmitter and a receiver,
it is advisable to decrease the range according to: wood and plaster - from 5 to 20, bricks - from 10 to 40 %, reinforced concrete - from 40 to 80 %, metal - from 90 to 100%,
glass - from 10 to 20 %. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system
have also a negative inuence on the range.
WARRANTY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-
TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
Salesman stamp and signature, date of sale
The ZAMEL company devices
which are characterised with
this sign can cooperate with
each other.
X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for Power Management IC Development Tools category:
Click to view products by Zamel manufacturer:
Other Similar products are found below :
EVAL6482H-DISC EVAL-AD5522EBUZ EVAL-ADM1060EBZ EVAL-ADM1073MEBZ EVAL-ADM1166TQEBZ EVAL-
ADM1168LQEBZ EVAL-ADM1171EBZ EVAL-ADM1276EBZ EVB-EN5319QI EVB-EN5365QI EVB-EN6347QI EVB-EP5348UI
MIC23158YML EV MIC23451-AAAYFL EV MIC5281YMME EV 124352-HMC860LP3E ADM00513 ADM8611-EVALZ ADM8612-
EVALZ ADM8613-EVALZ ADM8615-EVALZ ADP1046ADC1-EVALZ ADP1055-EVALZ ADP122-3.3-EVALZ ADP130-0.8-EVALZ
ADP130-1.2-EVALZ ADP130-1.5-EVALZ ADP130-1.8-EVALZ ADP160UJZ-REDYKIT ADP166UJ-EVALZ ADP1712-3.3-EVALZ
ADP1714-3.3-EVALZ ADP1715-3.3-EVALZ ADP1716-2.5-EVALZ ADP1740-1.5-EVALZ ADP1752-1.5-EVALZ ADP1754-1.5-EVALZ
ADP1828LC-EVALZ ADP1870-0.3-EVALZ ADP1871-0.6-EVALZ ADP1873-0.6-EVALZ ADP1874-0.3-EVALZ ADP1876-EVALZ
ADP1879-1.0-EVALZ ADP1882-1.0-EVALZ ADP1883-0.6-EVALZ ADP197CB-EVALZ ADP199CB-EVALZ ADP2102-1.25-EVALZ
ADP2102-1.2-EVALZ

Other manuals for ROP-01

2

This manual suits for next models

21

Other Zamel Transmitter manuals

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel EXTA LIFE RNP-21 User manual

Zamel

Zamel EXTA LIFE RNP-21 User manual

Zamel PDH-250 User manual

Zamel

Zamel PDH-250 User manual

Zamel EXTA LIFE RNM-24 User manual

Zamel

Zamel EXTA LIFE RNM-24 User manual

Zamel EXTA FREE RNK-04 User manual

Zamel

Zamel EXTA FREE RNK-04 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel RNL-01 User manual

Zamel

Zamel RNL-01 User manual

Zamel RTN-01 User manual

Zamel

Zamel RTN-01 User manual

Zamel exta life RNK-22 User manual

Zamel

Zamel exta life RNK-22 User manual

Zamel RNK-04 User manual

Zamel

Zamel RNK-04 User manual

Zamel RTN-01 Instruction Manual

Zamel

Zamel RTN-01 Instruction Manual

Zamel RNP-22 User manual

Zamel

Zamel RNP-22 User manual

Zamel exta life RNK-22 User manual

Zamel

Zamel exta life RNK-22 User manual

Popular Transmitter manuals by other brands

CYP PUV-1510TX Operation manual

CYP

CYP PUV-1510TX Operation manual

HITROL HT-100F Series instruction manual

HITROL

HITROL HT-100F Series instruction manual

Becker Centronic / B-Tronic EasyControl EC715 Assembly and operating instructions

Becker

Becker Centronic / B-Tronic EasyControl EC715 Assembly and operating instructions

RKI Instruments 65-2645RK-05-04 Operator's manual

RKI Instruments

RKI Instruments 65-2645RK-05-04 Operator's manual

Genie Intellicode II Series instructions

Genie

Genie Intellicode II Series instructions

Philips YKF355-005 user manual

Philips

Philips YKF355-005 user manual

Scott Instruments 4688IR Series Safety, Setup, Operation & Maintenance Manual

Scott Instruments

Scott Instruments 4688IR Series Safety, Setup, Operation & Maintenance Manual

YOKOGAWA YTA110 user manual

YOKOGAWA

YOKOGAWA YTA110 user manual

Upgrading everyday security EL4601 quick start guide

Upgrading everyday security

Upgrading everyday security EL4601 quick start guide

Honeywell K595 installation manual

Honeywell

Honeywell K595 installation manual

NIVELCO NIPRESS DRD-6 Series user manual

NIVELCO

NIVELCO NIPRESS DRD-6 Series user manual

Argos E0207TR-2 user manual

Argos

Argos E0207TR-2 user manual

DLO TransDock micro II user manual

DLO

DLO TransDock micro II user manual

Ameri-King AK-451 Series Installation and operation manual

Ameri-King

Ameri-King AK-451 Series Installation and operation manual

KMT TXS instruction manual

KMT

KMT TXS instruction manual

Emergency Caller Products LT-900 user manual

Emergency Caller Products

Emergency Caller Products LT-900 user manual

Pearce Simpson PANTHER SSB operating instructions

Pearce Simpson

Pearce Simpson PANTHER SSB operating instructions

Liberty Intelix INT-HD70-TXWP owner's manual

Liberty

Liberty Intelix INT-HD70-TXWP owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.