Step 1 Check if the DIN-Rail mounting kit is installed firmly.
Step 2 Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3 Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
Disassembling DIN-Rail
Step 1 Device power off.
Step 2 After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, then shift out the
bottom of DIN-Rail, disassembling ends.
Note before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
Power Supply Connection
DC power supply
This device provides 3-pin industrial terminal blocks (1, 2, 3),
among which 1 and 3 are 12~48VDC power supply inputs.
This power supply supports non-polarity, it
could run normally when reversely
connected.
【DIP Switch Setting】
Provide 4-bits DIP switch for function setting,
where "ON" is enable valid terminal. The
definitions of DIP switch as follows:
Checking LED Indicator
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table
below:
RUN
ON /
Device is in an abnormal state
Blinking Device runs normally
PWR
ON Power supply
is connected and
running normally
OFF Power supply is disconnected or
LINK(G1)
ON Local copper port is connected
Blinking Local copper port is in an active
OFF Local copper port
LINK(G2)
ON Local fiber
port is connected
properly
Blinking Local fiber
port is in an active
network state
OFF Local fiber port is not connected
LFP(G1)
ON
R
emote copper port is not
connected or connected
abnormally
OFF Remote copper port is connected
LFP(G2)
ON
Remote fiber
port is not
connected or connected
abnormally
OFF Remote fiber
port is connected
properly
Specification
Panel
Gigabit copper port 10/100/1000Base-T(X)
self-adaption, RJ45 port,
self-
adaptive full/half duplex
mode or specified operating
mode, supports MDI/MDI-X
Gigabit fiber port 1000Base-X
Indicator P
ower supply indicator,
running indicator, port
indicator, LFP indicator
Input power supply
12~48VDC
Support non-
polarity and
anti-reverse connection
Terminal blocks 3-pin 7.62mm