ABB Welcome M22344-W User manual

VER:1.2 ││28.04.2017
ABB-Welcome
Pos: 2 /Di nA4 - A nl eitun gen Online / Inh alt/K NX /Doo rE ntry /832 20-AP - xxx/ Tit elblat t - 832 20-AP -xxx - AB B @ 1 9\m od_ 132 3249 806 476 _15. doc x @ 11 108 4 @ @ 1
M22344-W
Basic 4.3" video hands-free
indoor station

ABB
-Welcome
| — 2 —
Pos: 4 /Bus c h-Ja ege r (N eust ruk t ur)/ Modul -St rukt u r/Onli ne-D oku ment ation /I nh altsve rz eich nis ( --> Fü r all e Doku men te <--)/I n haltsve rz eic hnis @ 19\ mod _13 206 490 4438 6_1 5.d ocx @ 109 653 @ @ 1
1Safety.......................................................................................................3
2Intended use.............................................................................................3
3Environment..............................................................................................3
3.1 ABB devices .............................................................................3
4Operations................................................................................................5
4.1 Standard operations..................................................................5
4.1.1 Control elements.......................................................................5
4.2 Control actions..........................................................................7
4.2.1 Incoming call/in a call................................................................7
4.2.2 Display and volume settings during a call...................................8
4.2.3 Communication menu ...............................................................9
4.3 Settings..................................................................................11
4.3.1 Overview ................................................................................11
4.3.2 Switch actuator settings...........................................................12
4.3.3 Program button settings ..........................................................13
4.3.4 Ringtone settings....................................................................14
4.3.5 Volume settings......................................................................15
4.3.6 Date and time settings.............................................................16
4.3.7 Other settings .........................................................................17
4.3.8 History review.........................................................................18
4.3.9 Language settings...................................................................20
4.3.10 Information..............................................................................20
4.3.11 Resetting factory default..........................................................21
4.4 Cleaning.................................................................................22
4.5 Adjusting the device................................................................23
5 Technical data.........................................................................................24
6Mounting/Installation...............................................................................25
6.1 Requirements for the electrician...............................................25
6.2 General installation instructions...............................................27
6.3 Mounting.................................................................................28

ABB
-Welcome
Pos: 6 /Bus c h-Ja ege r (N eust ruk t ur)/ Modul -St rukt u r/Onli ne-D oku ment ation /Ü be rschri ft en (- -> Für all e D okum ent e < --)/ 1. E b ene/S - T/S ic herhei t @ 18\ mod _13 026 127 917 90_ 15.d oc x @ 103 357 @ 1 @ 1
1Safety
Pos: 7 /Bus c h-Ja ege r (N eust ruk t ur)/ Modul -St rukt u r/Onli ne-D oku ment ation /S ic herhei t (-- > Für al le Dok um ente <- -)/Wa rn hinw eise /S icher hei t - 23 0 V @ 18\m od_ 130 260 681 675 0_15 .docx @ 1 033 08 @ @ 1
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or
indirect contact with live components.
This can result in electric shock, burns or even death.
■Disconnect the mains power supply prior to installation and/or
disassembly!
■Permit work on the 110-240 V supply system to be performed only by
specialist staff!
Pos: 8 /Bus c h-Ja ege r (N eust ruk t ur)/ Modul -St rukt u r/Onli ne-D oku ment ation /Ü be rschri ft en (- -> Für all e D okum ent e < --)/ 1. E b ene/A - F/B esti m mungs ge mä ßer Geb rau ch @ 18\ mod _13 027 6332 131 6_1 5.do cx @ 1034 83 @ 1 @ 1
2Intended use
Pos: 9 /Di nA4 - A nl eitun gen Onli ne /Inh alt/K NX /Doo rE ntry /832 20-AP - xxx /Best i mmu ngsg em aesse r Ge bra uch - 83 220 -A P-xx x- 500 @ 2 0\mo d_1 324 561 168 699 _15. docx @ 11 272 8 @ @ 1
The M22344-W is an integral part of the ABB-Welcome door entry system and operates
exclusively with components from this system. The device must only be installed in dry
indoor rooms.
Pos: 10 /B us ch-J aeg er (Neus t ruk tur )/M odul -Struk t ur/O nline -D oku me ntatio n/Ü be rsch rift e n (--> Fü r all e Doku men te < -- )/1. E bene /U - Z/U mwelt @ 18\ mod _13 026 141 5896 7_1 5.d ocx @ 103 383 @ 1 @ 1
3Environment
Pos: 11 /B us ch-J aeg er (Neus t ruk tur )/M odul -Struk t ur/O nline -D oku me ntatio n/U mw elt ( --> F ür all e Doku me nte <-- )/Hi nweis e/Hi nw eis - U mwelt - Hinw eis E lekt roge räte @ 1 8\mo d_1 302 763 973 434 _15. docx @ 10 350 0 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
household waste.
– The device contains valuable raw materials that can be recycled.
Therefore, dispose of the device at the appropriate collecting
facility.
Pos: 12 /Di nA4 - A nleit u ngen Onli n e/Ueb ersc hri ft en/2 ./A BB Gera ete @ 19 \mo d_1 323 162 843 832_ 15. doc x @ 11 087 5 @ 2 @ 1
3.1 ABB devices
Pos: 13 /B us ch-J aeg er (Neus t ruk tur )/M odul -Struk t ur/O nline -D oku me ntatio n/U mw elt ( --> F ür all e Doku me nte <-- )/Hi nweis e/Hi nw eis - U mwelt - AB B E lekt roger äte @ 19\ mo d_1 3231 627 458 39_ 15.d ocx @ 110 867 @ @ 1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packaging material and electric devices and their
components via an authorized collection facility or disposal company.

ABB
-Welcome
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)

ABB
-Welcome
Pos: 18 /Di nA4 - A nleit u ngen Onlin e/ Ueb ersc hrif t en/1 ./B edie nun g @ 18\m od_ 130 261 392 416 5_15 .doc x @ 1 033 65 @ 1 @ 1
4Operations
Pos: 19 /Di nA4 - A nleit u ngen Onli n e/Ueb ersc hri ft en/2 ./Nor mal e rB et rieb @ 18 \mo d_1 302 768 8209 65_ 15. docx @ 10 3540 @ 2 @ 1
4.1 Standard operations
Pos: 20 /Di nA4 - A nleit u ngen Onli n e/Ueb ersc hri ft en/3 ./B edie nele men te @ 20\ mod _13 232 6022 055 9_1 5.do cx @ 1 116 47 @ 3 @ 1
4.1.1 Control elements
Pos: 21 /Di nA4 - A nleit u ngen Onli n e/In halt/K NX /Do orE nt ry/83 220 -AP -xxx /Be di enel eme nte - 8 322 0-AP -xxx @ 18\ mo d_1 3032 128 536 05_ 15.d ocx @ 103 673 @ @ 1
Fig. 1 Control elements
1
3 4 5 6 72

ABB
-Welcome
No. Functions
14.3" Color display
2Communication button
2A For incoming call, press this button to activate the communication
within 30 seconds and press it again to end the call.
2B In standby mode, press this button to enter the communication menu.
If the LED flashes slowly, this means an incoming call.
If the LED illuminates, this means that a conversation is in progress.
If the LED flashes rapidly, it means system is busy.
3Unlock button
3A Press this button to open the door at any time.
4Surveillance button
4A In standby mode, press this button to survey the default outdoor station.
4B While the display is on, press this button to the survey the next outdoor
station. (This function is available depending on the installation type.)
4C While the display is on, hold this button to take a snapshot.
4D In standby mode, if the LED flashes, press this button to display the
"History" record.
If the LED flashes slowly, this represents a notification of a missed
call.
5Mute button
5A In standby mode, press this button to mute ringtone of the indoor
station.
5B In standby mode, hold the button to mute ringtone of all indoor stations
in the apartment.
5C Press this button to reject incoming call.
5D During the conversation, press this button to mute microphone.
The LED illuminates to indicate mute status.
6Programmable button 1
6A Release the second lock connected with an outdoor station (default
function).
6B *Programmable button for additional functions, e.g. call to guard unit,
7System setting button
Enter the system setting menu for various functions of the device.
If the LED flashes rapidly, it means that setting is busy.
*For use of those buttons, please contact your electrical installer.
Pos: 22 /B us ch-J aeg er (Neus t ruk tur )/M odul -Struk t ur/O nline -D oku me ntatio n/S teu er mod ule - Onl in e-Dok ume ntati on ( -- > Für al le Dok ume nte <- -)/ +++++ ++ +++ ++S eiten umb ruch + +++++ ++ +++ +@ 9\m od_ 126 8898 668 093 _0. docx @ 521 49 @ @ 1

ABB
-Welcome
Pos: 26 /Di nA4 - A nleit u ngen Onlin e/ Ueb ersc hrif t en/2 ./B edie nakti onen @ 2 0\m od_ 1323 262 294 281 _15. docx @ 11 191 1 @ 2 @ 1
4.2 Control actions
Pos: 27 /Di nA4 - A nleit u ngen Onlin e/ Ueb ersc hrif t en/3 ./S prec h- und Vi deov erbi ndu ng @ 20\ mod _13 232 6236 870 0_1 5.do cx @ 1119 27 @ 3 @ 1
4.2.1 Incoming call/in a call
Pos: 28 /Di nA4 - A nleit u ngen Onli n e/In halt/K NX /Do orE nt ry/83 220 -AP -xxx /Sp rech - u nd V ide over bi nd ung - 8 322 0-AP -xxx @ 20\ mo d_1 3232 623 418 52_ 15.d ocx @ 111 919 @ @ 1
Fig. 2 Incoming call/in a call
During a call, the following functions are available:
No. Functions
1Press this button to accept incoming call. In a call, press this button to end
the call.
2Press this button to open the door where the call is from.
3-A Press this button to survey the analog camera of the outdoor station if
there is one.
3-B Hold this button to take a snapshot.
4Press this button to mute the ringtone of an incoming call. In a call, press
this button to mute the microphone.
5-A Press this button to activate the function of the programmable button.
5-B If the function "release second lock" or "control switch actuator" is assigned
to the programmable button, press this button to activate the function.
6-A
6-B Press this button to enable or disable the full-screen function.
Hold this button to enter the brightness and volume setttings menu.
7Time left of the connection.
8Number of outdoor stations
Pos: 29 /B us ch-J aeg er (Neus t ruk tur )/M odul -Struk t ur/O nline -D oku me ntatio n/S teu er mod ule - Onl in e-Dok ume ntati on ( -- > Für al le Dok ume nte <- -)/ +++++ ++ +++ ++S eiten umb ruch + +++++ ++ +++ +@ 9\m od_ 126 8898 668 093 _0. docx @ 521 49 @ @ 1
30s
Outdoor 1
136
7
8
2 4 5

ABB
-Welcome
Pos: 30 /Di nA4 - A nleit u ngen Onlin e/ Ueb ersc hrif t en/3 ./T uer oeff nen @ 2 0\mo d_1 323 263 277 453 _15. doc x @ 11 193 5 @ 3 @ 1
4.2.2 Display and volume settings during a call
Pos: 31 /Di nA4 - A nleit u ngen Onlin e/ In halt/K NX /Do orE nt ry/83 220 -AP -xxx/ Tuer o eff ne n - 832 20-A P-x xx @ 20\ mod_ 132 326 795 847 9_15 . docx @ 1 121 09 @ @ 1
Fig. 3 Display and volume settings during a call
Hold button for 3s to enter the display and volume setttings menu during a call or
conversation. The following functions are available.
No. Functions
1Navigation buttons ( up, down, confirm, cancel etc.)
2Press the navigation buttons as needed.
3Speech volume (can only be adjusted during conversation).
4Saturation
5Brightness
6Value set
Pos: 32 /B us ch-J aeg er (Neus t ruk tur )/M odul -Struk t ur/O nline -D oku me ntatio n/S teu er mod ule - Onl in e-Dok ume ntati on ( -- > Für al le Dok ume nte <- -)/ +++++ ++ +++ ++S eiten umb ruch + +++++ ++ +++ +@ 9\m od_ 126 8898 668 093 _0. docx @ 521 49 @ @ 1
120s
Outdoor 1
24
5
6
1
2
3

ABB
-Welcome
Pos: 33 /Di nA4 - A nleit u ngen Onlin e/ Ueb ersc hrif t en/3 ./S tum ms c halte n @ 2 0\ mod_ 132 326 360 7142 _15 . docx @ 1 119 51 @ 3 @ 1
Pos: 66 /B us ch-J aeg er (Neus t ruk tur )/M odul -Struk t ur/O nline -D oku me ntatio n/S teu er mod ule - Onl in e-Dok ume ntati on ( -- > Für al le Dok ume nte <- -)/ +++++ ++ +++ ++S eiten umb ruch + +++++ ++ +++ +@ 9\m od_ 126 8898 668 093 _0. docx @ 521 49 @ @ 1
4.2.3 Communication menu
Pos: 31 /Di nA4 - A nleit u ngen Onlin e/ In halt/K NX /Do orE nt ry/83 220 -AP -xxx/ Tuer o eff ne n - 832 20-A P-x xx @ 20\ mod_ 132 326 795 847 9_15 . docx @ 1 121 09 @ @ 1
4.2.3.1 Overview
Press button to enter the communication menu. The following functions are available:
No. Functions
1Call to guard unit
-Call guard unit directly.
2Switch actuator
-Activate the existing actuator list.
4.2.3.2 Call to guard unit
Fig. 4: Call to guard unit
CALL GUARD UNIT
Call Guard Unit

ABB
-Welcome
4.2.3.3 Switch actuator
Fig. 5: Switch actuator
Set the actuator list in the “system settings-switch actuator” menu first.
After choosing a list, press button √to enable the lock or light, which is connected with the
switch actuator.
SWITCH ACTUATOR
Actuator 1 (001)

ABB
-Welcome
4.3 Settings
4.3.1 Overview
Press button to enter the system settings menu. The following functions are available:
No. Functions
1Switch actuator
-Set the actuator list in this menu.
2Program button
-Set functions for programmable buttons.
3 Ringtone
-Set the ringtone for outdoor bells, indoor bell or others.
4Volume
-Set volume of ringtone.
5Date and time
-Set different times.
6 Other settings
-Other settings, e.g. auto full screen.
7History
-View all communication entries in the menu, e.g. received calls, missed
calls.
8Language
-Set the local language.
9 Information
10 Reset factory default.
Pos: 27 /Di nA4 - A nleit u ngen Onlin e/ Ueb ersc hrif t en/3 ./S prec h- und Vi deov erbi ndu ng @ 20\ mod _13 232 6236 870 0_1 5.do cx @ 1119 27 @ 3 @ 1

ABB
-Welcome
4.3.2 Switch actuator settings
Fig. 6: Switch actuator settings
No. Functions
1Existing switch actuator list: Press button √to modify the settings.
2Add a new actuator list. A total of 10 switch actuator lists can be added.
3Enter to change target address with “+” or “-” button from 001 to 199.
4 Rename the switch actuator list:
Scroll through letters of the alphabet or numbers one by one with “+” or
“-” button
3
4
SWITCH ACTUATOR
Actuator 1 (001)
Add New
Target Address
Rename
002
light
Save Cancel
SWITCH ACTUATOR
2
1
Add a new list

ABB
-Welcome
4.3.3 Program button settings
Fig. 7: Program button settings
No. Functions
1Set functions for the program button, e.g. releasing 2nd-lock, calling guard
unit, enabling the switch actuator.
*Only the switch actuator list can be assigned to the program button.
Button 1 Release 2nd-Lock
PROGRAM BUTTON
1

ABB
-Welcome
4.3.4 Ringtone settings
Fig. 8: Ringtone
No. Functions
1Select the bell sound for the default outdoor station.
2Select the bell sound for other outdoor stations.
3Select the bell sound for the apartment door.
4Select the bell sound for others, e.g. a call from the guard unit.
1
Default Outdoor
Other Outdoors
RING TONE
Ring Tone 1
Ring Tone 2 2
Doorbell
Ring Tone 3
Others
Ring Tone 4
3
4

ABB
-Welcome
4.3.5 Volume settings
Fig. 9:Volume settings
No. Functions
1Set the volume of bell sound.
2Enable/disable the feedback tone that sounds when the touch button is
pressed.
3The ringtone can be set as fixed or cycled.
1
Ringtone Volume
Touchbutton Tone
VOLUME
Volume 3
2
√
Repeated Tone
√3

ABB
-Welcome
4.3.6 Date and time settings
Fig. 10: Date and time settings
No. Functions
1Set the date.
2Set the time.
3Enable/disable the summer time function.
1
Date(YYYY-MM-DD)
Time
DATE AND TIME
2013
2
08
Summer Time
√
:
00
-
01
-
01
3

ABB
-Welcome
4.3.7 Other settings
Fig. 11: Other settings
No. Functions
1Enable/disable the auto full screen function.
2Enable/disable the auto-snapshot function.
3Enable/disable the missed call function. ( flashes when there is a missed
call).
1
Auto Full Screen
Auto
-
snapshots
OTHER SETTINGS
√
2
Missed
√
√3

ABB
-Welcome
4.3.8 History review
Fig. 12: History review
No. Functions
1Up to 100 events can be recorded in the history menu.
-If the snapshot function is enabled, an icon is diplayed.
-Date, time and type of the event are recorded together with the
snapshot.
- Directions: means dialing calls
means receiving calls
means missed calls
2Press this button to view details of this event.
●
HISTORY
1/2
Outdoor -1
1/63
2013-03-21
16:45 Outdoor - 1
●
2013-03-21
16:45
Outdoor - 1
●
2013-03-21
14:24
Outdoor - 1
1
2
3

ABB
-Welcome
Two photos are always made when a visitor rings the bell.
3Press this button to delete a record item.

ABB
-Welcome
4.3.9 Language settings
Fig. 13: Language settings
4.3.10 Information
Fig. 14: Information for the indoor station. (Scan the QR code to get detailed instruction for
indoor station.)
English
LANGUAGE
Flash Version: V1.02_151210_US
INFORMATION
MCU Version: V1.02_151210_US
M/S: Master
Default Outdoor: 1
Indoor St. Add.: 001
Other manuals for Welcome M22344-W
2
This manual suits for next models
2
Table of contents
Other ABB Security System manuals

ABB
ABB 83327-500 User manual

ABB
ABB L240 Series Guide

ABB
ABB FIM 1300 Series User manual

ABB
ABB ZMT Zirconia User manual

ABB
ABB SACO 16D1 User manual

ABB
ABB M22411-W User manual

ABB
ABB Arc Guard System TVOC-2 Product manual

ABB
ABB N9611.02 Operation and maintenance manual

ABB
ABB Welcome M21311P1-A Setup guide

ABB
ABB 83220 AP-5 series User manual