manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Cables And Connectors
  8. •
  9. ADTRAN 1184544P2 User manual

ADTRAN 1184544P2 User manual

Other ADTRAN Cables And Connectors manuals

ADTRAN jobAid+ 1200487G10 User manual

ADTRAN

ADTRAN jobAid+ 1200487G10 User manual

ADTRAN 1445003F1 User manual

ADTRAN

ADTRAN 1445003F1 User manual

ADTRAN 1442200G1 User manual

ADTRAN

ADTRAN 1442200G1 User manual

ADTRAN BVL3AH1D Series User manual

ADTRAN

ADTRAN BVL3AH1D Series User manual

ADTRAN 1184561P4 User manual

ADTRAN

ADTRAN 1184561P4 User manual

ADTRAN BVL3AWWD Series User manual

ADTRAN

ADTRAN BVL3AWWD Series User manual

ADTRAN 3192 HDSL4 Operating instructions

ADTRAN

ADTRAN 3192 HDSL4 Operating instructions

ADTRAN 144298XGX User manual

ADTRAN

ADTRAN 144298XGX User manual

ADTRAN Total Access 3010 User manual

ADTRAN

ADTRAN Total Access 3010 User manual

ADTRAN BVL3ARLD Series User manual

ADTRAN

ADTRAN BVL3ARLD Series User manual

ADTRAN GPON User manual

ADTRAN

ADTRAN GPON User manual

ADTRAN BVL3AH0D Series User manual

ADTRAN

ADTRAN BVL3AH0D Series User manual

ADTRAN 1442520G1 User manual

ADTRAN

ADTRAN 1442520G1 User manual

ADTRAN 1184544P5 User manual

ADTRAN

ADTRAN 1184544P5 User manual

ADTRAN Cable Kit Tracer 3202 User manual

ADTRAN

ADTRAN Cable Kit Tracer 3202 User manual

ADTRAN SOOTAK8J Series User manual

ADTRAN

ADTRAN SOOTAK8J Series User manual

ADTRAN Total Access 5000 User manual

ADTRAN

ADTRAN Total Access 5000 User manual

ADTRAN 1200487G80 User manual

ADTRAN

ADTRAN 1200487G80 User manual

Popular Cables And Connectors manuals by other brands

StarTech.com ST124HD20 quick start guide

StarTech.com

StarTech.com ST124HD20 quick start guide

Philips SWV4543S/10 Features

Philips

Philips SWV4543S/10 Features

Larson Electronics 10-50C instruction manual

Larson Electronics

Larson Electronics 10-50C instruction manual

Grip MEK-PM Assembly and operating manual

Grip

Grip MEK-PM Assembly and operating manual

Ultra Products Travel Pack #3 ULT31436 Specifications

Ultra Products

Ultra Products Travel Pack #3 ULT31436 Specifications

Surpass QCH-F Operation manual

Surpass

Surpass QCH-F Operation manual

Philips SWA6310 Specifications

Philips

Philips SWA6310 Specifications

StarTech.com CRJ4550PK quick start guide

StarTech.com

StarTech.com CRJ4550PK quick start guide

Nohau EMUL-IP2K-PC user guide

Nohau

Nohau EMUL-IP2K-PC user guide

Foxun SX-SP144E-HD4K2K operating instructions

Foxun

Foxun SX-SP144E-HD4K2K operating instructions

Philips SWA3305W Specifications

Philips

Philips SWA3305W Specifications

opticis Stretch DVIM1-1P0x user manual

opticis

opticis Stretch DVIM1-1P0x user manual

Volkswagen VAS 6558A operating manual

Volkswagen

Volkswagen VAS 6558A operating manual

NEXIBO N-13 user manual

NEXIBO

NEXIBO N-13 user manual

CYP PU-1H3HBTL Operation manual

CYP

CYP PU-1H3HBTL Operation manual

Allen-Bradley 1784-u2dhp installation instructions

Allen-Bradley

Allen-Bradley 1784-u2dhp installation instructions

Global Caché Flex Link Blaster quick start

Global Caché

Global Caché Flex Link Blaster quick start

Hauppauge USB-Live2 Quick installation guide

Hauppauge

Hauppauge USB-Live2 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

jobAid
DESCRIPTION
TheSmallForm‐FactorPluggableOC‐1215kmIntermediate
Reach‐1(SFPIR‐1)plugsintoADTRANequipmentdesignedto
acceptSmallForm‐factorPluggables(SFPs).Installedintoan
appropriatehostunit,theSFPIR‐1providesanOC‐12interfaceto
thesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPIR‐1:
♦SONETOC‐12compatible(622Mb/s),1310nmintermediate
reach,singlemode,2‐fiberoperation
♦15kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦OpticalSpecifications:
◊Transmitpower:–15dBmto–8dBm
◊Receivepower:–28dBmto–8dBm
◊TransmitWavelength:1310nm
◊Opticalbudget:12dB
◊Opticalconnectors:LC
Small Form-Factor Pluggable OC-12
15 km Intermediate Reach-1
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+65°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
INSTALLATION
ToinstalltheSFPIR‐1intoanappropriatemodule,completethe
followingsteps:
1. InspecttheSFPIR‐1.Ifdamaged,fileaclaimwiththecarrier
andthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPIR‐1intotheSFPcageonthemodule.Ensure
thatthemanufacturer’slabelontheSFPisfacingupwardfor
correctinstallation.
3. SlidetheSFPIR‐1allthewayintothereceptacleuntilthere
isanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheSFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.TheSFPIR‐1isintendedfordeploymentinCentralOffice
typefacilities,EEEs,EECs,andlocationswheretheNECapplies
(forexample,CustomerPremises).
TheSFPistobeinstalledinADTRANproductsinRestricted
AccessLocationsonly,andinstalledbytrainedservicepersonnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
CLEI: SOOTAE4J__
Product P/N: 1184544P2
Issue Date: December 2010
Document P/N: 61184544P2-22E
C A U T I O NC A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61184544P2-22E*
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheSFPisbeing
deployedinisdesignedandintendedforinstallationaspartof
aCommonBondingNetwork(CBN).TheADTRANsystem
thattheSFPisbeingdeployedinisnotdesignednorintended
forinstallationaspartofanIsolatedBondingNetwork(IBN).
♦ PerGR‐1089‐CORESection9,theSFPIR‐1doesnothavean
internalDCconnectionbetweenbatteryreturnandframe
ground.TheSFPIR‐1canbeinstalledinaDC‐I(isolated)or
DC‐C(common)installation.Forinstallationswhereother
cardsorthehostsystemhaveinternalconnectionsbetween
batteryreturnandframeground,thesystemwouldbe
intendedfordeploymentonlyinaDC‐Cinstallation.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPIR‐1isproperlygroundedviathe
backplaneconnector.
CAUTION
C
TheSmallForm‐FactorPluggableOC‐1215kmIntermediate
Reach‐1isaClass1LaserProductandcomplieswiththeLaser
SafetyrequirementsofFDA21CFR1040.11,EN60825‐1,and
EN60825‐2.TheSFPIR‐1isNRTLListedandCBCertifiedtoall
applicableAmericanandEuropeansafetystandards.
NOTE
♦ TheGigabitEthernetport(s)areopticalandthereforearenot
classifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐COREIssue5.
♦ ThisSFPIR‐1iscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3.
♦ ThisSFPIR‐1iscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ ThisSFPIR‐1isdesignedtobedeployedinGR‐3108‐CORE
environmentalclass1or2asdefinedinGR‐3108‐COREIssue
2.
TheSFPIR‐1isdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
TheSmallForm‐FactorPluggableOC‐1215kmIntermediate
Reach‐1meetsEURoHSDirective2002/95/ECand/orapplicable
exemptions.Refertowww.adtran.comforfurtherinformationon
RoHS/WEEE.