DESCRIPTION
TheSmallForm‐FactorPluggableOC‐1215kmIntermediate
Reach‐1(SFPIR‐1)plugsintoADTRANequipmentdesignedto
acceptSmallForm‐factorPluggables(SFPs).Installedintoan
appropriatehostunit,theSFPIR‐1providesanOC‐12interfaceto
thesupportingsystem.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheSFPIR‐1:
♦SONETOC‐12compatible(622Mb/s),1310nmintermediate
reach,singlemode,2‐fiberoperation
♦15kmmaximumopticalspan
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs
suppliedbyADTRANwiththehostmodule.ADTRANcannot
certifysystemintegritywithotherSFPs.
SPECIFICATIONS
♦OpticalSpecifications:
◊Transmitpower:–15dBmto–8dBm
◊Receivepower:–28dBmto–8dBm
◊TransmitWavelength:1310nm
◊Opticalbudget:12dB
◊Opticalconnectors:LC
Small Form-Factor Pluggable OC-12
15 km Intermediate Reach-1
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–40°Cto+65°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto95%,noncondensing
INSTALLATION
ToinstalltheSFPIR‐1intoanappropriatemodule,completethe
followingsteps:
1. InspecttheSFPIR‐1.Ifdamaged,fileaclaimwiththecarrier
andthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheSFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheSFPIR‐1intotheSFPcageonthemodule.Ensure
thatthemanufacturer’slabelontheSFPisfacingupwardfor
correctinstallation.
3. SlidetheSFPIR‐1allthewayintothereceptacleuntilthere
isanaudible“click”.
NOTE
ThelatchontheSFPisusedtoremovetheSFPfromthecageon
thecircuitcard.
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheSFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.TheSFPIR‐1isintendedfordeploymentinCentralOffice
typefacilities,EEEs,EECs,andlocationswheretheNECapplies
(forexample,CustomerPremises).
TheSFPistobeinstalledinADTRANproductsinRestricted
AccessLocationsonly,andinstalledbytrainedservicepersonnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
CLEI: SOOTAE4J__
Product P/N: 1184544P2
Issue Date: December 2010
Document P/N: 61184544P2-22E
C A U T I O NC A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2010 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61184544P2-22E*
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheSFPisbeing
deployedinisdesignedandintendedforinstallationaspartof
aCommonBondingNetwork(CBN).TheADTRANsystem
thattheSFPisbeingdeployedinisnotdesignednorintended
forinstallationaspartofanIsolatedBondingNetwork(IBN).
♦ PerGR‐1089‐CORESection9,theSFPIR‐1doesnothavean
internalDCconnectionbetweenbatteryreturnandframe
ground.TheSFPIR‐1canbeinstalledinaDC‐I(isolated)or
DC‐C(common)installation.Forinstallationswhereother
cardsorthehostsystemhaveinternalconnectionsbetween
batteryreturnandframeground,thesystemwouldbe
intendedfordeploymentonlyinaDC‐Cinstallation.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheSFPIR‐1isproperlygroundedviathe
backplaneconnector.
CAUTION
C
TheSmallForm‐FactorPluggableOC‐1215kmIntermediate
Reach‐1isaClass1LaserProductandcomplieswiththeLaser
SafetyrequirementsofFDA21CFR1040.11,EN60825‐1,and
EN60825‐2.TheSFPIR‐1isNRTLListedandCBCertifiedtoall
applicableAmericanandEuropeansafetystandards.
NOTE
♦ TheGigabitEthernetport(s)areopticalandthereforearenot
classifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐COREIssue5.
♦ ThisSFPIR‐1iscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3.
♦ ThisSFPIR‐1iscompliantwiththeSmallForm‐Factor
Pluggable(SFP)Multi‐SourceAgreement(MSA).
♦ ThisSFPIR‐1isdesignedtobedeployedinGR‐3108‐CORE
environmentalclass1or2asdefinedinGR‐3108‐COREIssue
2.
TheSFPIR‐1isdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
TheSmallForm‐FactorPluggableOC‐1215kmIntermediate
Reach‐1meetsEURoHSDirective2002/95/ECand/orapplicable
exemptions.Refertowww.adtran.comforfurtherinformationon
RoHS/WEEE.

Other ADTRAN Cables And Connectors manuals

ADTRAN 1442520G1 User manual

ADTRAN

ADTRAN 1442520G1 User manual

ADTRAN 1184561P4 User manual

ADTRAN

ADTRAN 1184561P4 User manual

ADTRAN GPON User manual

ADTRAN

ADTRAN GPON User manual

ADTRAN BVL3AH1D Series User manual

ADTRAN

ADTRAN BVL3AH1D Series User manual

ADTRAN 1200487G80 User manual

ADTRAN

ADTRAN 1200487G80 User manual

ADTRAN BVL3AWWD Series User manual

ADTRAN

ADTRAN BVL3AWWD Series User manual

ADTRAN 144298XGX User manual

ADTRAN

ADTRAN 144298XGX User manual

ADTRAN SOOTAK8J Series User manual

ADTRAN

ADTRAN SOOTAK8J Series User manual

ADTRAN Total Access 5000 User manual

ADTRAN

ADTRAN Total Access 5000 User manual

ADTRAN Total Access 3010 User manual

ADTRAN

ADTRAN Total Access 3010 User manual

ADTRAN 1445003F1 User manual

ADTRAN

ADTRAN 1445003F1 User manual

ADTRAN jobAid+ 1200487G10 User manual

ADTRAN

ADTRAN jobAid+ 1200487G10 User manual

ADTRAN Cable Kit Tracer 3202 User manual

ADTRAN

ADTRAN Cable Kit Tracer 3202 User manual

ADTRAN BVL3AH0D Series User manual

ADTRAN

ADTRAN BVL3AH0D Series User manual

ADTRAN 1184544P5 User manual

ADTRAN

ADTRAN 1184544P5 User manual

ADTRAN 1442200G1 User manual

ADTRAN

ADTRAN 1442200G1 User manual

ADTRAN 3192 HDSL4 Operating instructions

ADTRAN

ADTRAN 3192 HDSL4 Operating instructions

ADTRAN BVL3ARLD Series User manual

ADTRAN

ADTRAN BVL3ARLD Series User manual

Popular Cables And Connectors manuals by other brands

NEUTRIK Dual Plug NP3TT-2 Assembly instructions

NEUTRIK

NEUTRIK Dual Plug NP3TT-2 Assembly instructions

Burndy Continental Industries ThermOweld AC-1 instructions

Burndy

Burndy Continental Industries ThermOweld AC-1 instructions

Tektronix Keithley 2290-10-SHV manual

Tektronix

Tektronix Keithley 2290-10-SHV manual

CableWholesale 41V3-08100 user manual

CableWholesale

CableWholesale 41V3-08100 user manual

Dixon Bayco FloTech FT450 installation instructions

Dixon Bayco

Dixon Bayco FloTech FT450 installation instructions

AV Access SP0102-H00 user manual

AV Access

AV Access SP0102-H00 user manual

Panduit FLCSHMIG installation instructions

Panduit

Panduit FLCSHMIG installation instructions

Triton Blue DMX Spliter 4R user manual

Triton Blue

Triton Blue DMX Spliter 4R user manual

Antex electronics RG-6 Extension Cable PRO-100 Specifications

Antex electronics

Antex electronics RG-6 Extension Cable PRO-100 Specifications

NEMECHEK TECHNOLOGIES Vitality SMARTCABLE user guide

NEMECHEK TECHNOLOGIES

NEMECHEK TECHNOLOGIES Vitality SMARTCABLE user guide

Burndy Continental Industries thermOweld BX-1 instructions

Burndy

Burndy Continental Industries thermOweld BX-1 instructions

ELEKTRA SelfTec PRO Series installation manual

ELEKTRA

ELEKTRA SelfTec PRO Series installation manual

HRS GT36 instruction manual

HRS

HRS GT36 instruction manual

Sennheiser ASA 1 instruction manual

Sennheiser

Sennheiser ASA 1 instruction manual

Harwin M80-940 Series Assembly instructions

Harwin

Harwin M80-940 Series Assembly instructions

Wheelock SP4-APS installation instructions

Wheelock

Wheelock SP4-APS installation instructions

GEM BLN-RJ45 manual

GEM

GEM BLN-RJ45 manual

Wallenstein WX370 Operator's manual

Wallenstein

Wallenstein WX370 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.