DESCRIPTION
The Small Form-Factor Pluggable (SFP) Gigabit Ethernet,
Single-Fiber is a bidirectional SFP that plugs into an
Optical Line Terminal (ONU) designed to accept SFPs. The
SFP provides a single optical interface to the GigE physical
interface. Installed into an appropriate ONU, the SFP
provides a Gigabit Ethernet interface to the supporting
system.
NOTE
To ensure compatibility, refer to the documentation
provided with the ONU.
NOTICE
In a deployment consisting of an OLT with a 1442180G1
SFP installed; the Network Unit (ONT) should have a
complementary 1200487G80 SFP installed.
The following features are supported on the SFP:
♦1000Base-LX 1490 nm Transmitter
♦1000Base-LX 1550 nm Receiver
♦Optical distance: 80 km maximum
CAUTION
!
Due to compliance certification requirements, only SFPs
supplied by ADTRAN should be used. ADTRAN cannot
certify system integrity with other SFPs.
OLT
1442180G1 1200487G80
ONU
Rx: 1490 nm
Tx: 1550 nm
Rx: 1550 nm
Tx: 1490 nm
Small Form-Factor Pluggable
1490 nm TX / 1550 nm RX, 80 km
Operational Specifications
♦Optical Specifications:
◊Transmit wavelength: 1490 nm
◊Receive wavelength: 1550 nm
◊Optical transmit level: –2 dBm to +3 dBm
◊Optical receive level: –25 dBm to –3 dBm
◊Optical distance: 80 km
◊Optical connectors: LC
♦Extended Environmental Support:
◊Operational temperature range: –40°C to +70°C
◊Storage temperature range: –40°C to +85°C
◊Relative humidity to 95%, noncondensing
INSTALLATION
Prior to installation, inspect the SFP. If damage has occured
during shipping, file a claim with the carrier, and then
contact ADTRAN Customer Support. For more infor-
mation, refer to “Warranty”.
To install the SFP into an appropriate module, complete
the following steps:
1. Insert the SFP into the SFP cage on the circuit board of
the host module with the latch handle facing outward.
Slide the SFP all the way into the cage.
NOTE
The latch on the SFP is for removal only. When removing
the SFP, rotate the latch away from the SFP, the SFP should
slide easily out of the cage.
2. Exert adequate pressure to ensure the SFP is
completely seated in the SFP cage.
3. Do not remove the connector plug until the optical
fiber connection is made.
NOTICE
It is recommended that the connector plug remain on
whenever the transciever optical fiber connector is not
inserted.
4. Continue the installation and turn-up of the host
module using the instructions in the Job Aid provided
with the module, or using the Installation and
Maintenance Guide (I&M) available online at
www.adtran.com.
CLEI: BVL3ALHD_ _
Product P/N: 1200487G80
Issue Date: January 2011
Document P/N: 61200487G80-22A
CAUTION!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2011 ADTRAN, Inc. All Rights Reserved.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61200487G80-22A*
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
Electrostatic Discharge (ESD) can damage electronic
modules. When handling modules, wear an antistatic
discharge wrist strap to prevent damage to electronic
components. Place modules in antistatic packing material
when transporting or storing. When working on modules,
always place them on an approved antistatic mat that is
electrically grounded.
The SFP is NRTL Listed to the applicable UL standards.
The SFP meets or exceeds all the applicable requirements
of NEBS, Telcordia GR-63-CORE, and GR-1089-CORE. The
SFP is intended for deployment in Central Office type facil-
ities, EEEs, EECs, and locations where the NEC applies (for
example, Customer Premises) and is intended to be
installed by trained service personnel. Install the SFP in an
ADTRAN product located in a restricted access location.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user's authority to operate this
equipment.
CAUTION
!
♦ Per GR-1089-CORE the ADTRAN system that the SFP is
being deployed in is designed and intended for
installation as part of a Common Bonding Network
(CBN). The ADTRAN system that the SFP is being
deployed in is not designed nor intended for installation
as part of an Isolated Bonding Network (IBN).
♦ Per GR-1089-CORE Section 9, the SFP does not have an
internal DC connection between battery return and
frame ground. The SFP can be installed in a DC-I
(isolated) or DC-C (common) configuration. For
installations where other cards or the host system have
internal connections between battery return and frame
ground, the system would be intended for deployment
only in a DC-C configuration.
♦ The ADTRAN system chassis frame ground terminal
must be connected to an earth ground to ensure that the
metal enclosure of the SFP is properly grounded via the
backplane connector.
CAUTION
C
The XFP is a Class 1 Laser Product and complies with the
Laser Safety requirements of FDA 21CFR 1040.10 and
1040.11, and IEC60825-1 and -2. The XFP is NRTL listed
and CB Certified to all applicable American and European
safety standards.
For continued compliance with the above laser safety
standards, only approved Class 1 modules from our
approved vendor list, located on the ADTRAN website,
should be installed in ADTRAN products.
NOTE
The Gigabit Ethernet port(s) are optical and therefore are
not classified as any type of port as defined in Appendix B
of GR-1089-CORE Issue 5.
The SFP is designed to meet the following environmental
classes:
♦ETSI EN 300 019-1-1 “Classification of environmental
conditions; Storage,” Class 1.2
♦ETSI EN 300 019-1-2 “Classification of environmental
conditions, Transportation,” Class 2.3
♦ETSI EN 300 019-1-3 “Classification of environmental
conditions, Stationary use at weather-protected
locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 3.3 of
ETSI EN 300 019-1-3.
The SFP meets the EU’s RoHS Directive 2002/95/EC and/
or applicable exemptions. Refer to www.adtran.com for
further information on RoHS/WEEE.

Other ADTRAN Cables And Connectors manuals

ADTRAN jobAid+ 1200487G10 User manual

ADTRAN

ADTRAN jobAid+ 1200487G10 User manual

ADTRAN GPON User manual

ADTRAN

ADTRAN GPON User manual

ADTRAN Total Access 5000 User manual

ADTRAN

ADTRAN Total Access 5000 User manual

ADTRAN BVL3ARLD Series User manual

ADTRAN

ADTRAN BVL3ARLD Series User manual

ADTRAN BVL3AH1D Series User manual

ADTRAN

ADTRAN BVL3AH1D Series User manual

ADTRAN 1442520G1 User manual

ADTRAN

ADTRAN 1442520G1 User manual

ADTRAN BVL3AH0D Series User manual

ADTRAN

ADTRAN BVL3AH0D Series User manual

ADTRAN 1184561P4 User manual

ADTRAN

ADTRAN 1184561P4 User manual

ADTRAN 144298XGX User manual

ADTRAN

ADTRAN 144298XGX User manual

ADTRAN 1442200G1 User manual

ADTRAN

ADTRAN 1442200G1 User manual

ADTRAN 1184544P2 User manual

ADTRAN

ADTRAN 1184544P2 User manual

ADTRAN 1445003F1 User manual

ADTRAN

ADTRAN 1445003F1 User manual

ADTRAN 1184544P5 User manual

ADTRAN

ADTRAN 1184544P5 User manual

ADTRAN BVL3AWWD Series User manual

ADTRAN

ADTRAN BVL3AWWD Series User manual

ADTRAN 3192 HDSL4 Operating instructions

ADTRAN

ADTRAN 3192 HDSL4 Operating instructions

ADTRAN Total Access 3010 User manual

ADTRAN

ADTRAN Total Access 3010 User manual

ADTRAN SOOTAK8J Series User manual

ADTRAN

ADTRAN SOOTAK8J Series User manual

ADTRAN Cable Kit Tracer 3202 User manual

ADTRAN

ADTRAN Cable Kit Tracer 3202 User manual

Popular Cables And Connectors manuals by other brands

Lindy 38406 user manual

Lindy

Lindy 38406 user manual

Clas Ohlson LCH1312.68-3P quick start guide

Clas Ohlson

Clas Ohlson LCH1312.68-3P quick start guide

Wheelock SPL installation instructions

Wheelock

Wheelock SPL installation instructions

Jasco cordinate 37920 user manual

Jasco

Jasco cordinate 37920 user manual

TE Connectivity D-150-Z Series Installation procedures

TE Connectivity

TE Connectivity D-150-Z Series Installation procedures

IAdea PSP-102U user manual

IAdea

IAdea PSP-102U user manual

AVYCON AVA HDMI-SPT-1IN4OUT-HDR2 manual

AVYCON

AVYCON AVA HDMI-SPT-1IN4OUT-HDR2 manual

Philips SWA6713 Specifications

Philips

Philips SWA6713 Specifications

Allen-Bradley 1769 CompactLogix installation instructions

Allen-Bradley

Allen-Bradley 1769 CompactLogix installation instructions

Philips SWV3435W Specifications

Philips

Philips SWV3435W Specifications

CYP CLUX-18E Operation manual

CYP

CYP CLUX-18E Operation manual

Splitvolt EGB 11-016 Quick start user guide

Splitvolt

Splitvolt EGB 11-016 Quick start user guide

Festo NEBM-M23G12-E N-S1G9 Series Assembly instructions

Festo

Festo NEBM-M23G12-E N-S1G9 Series Assembly instructions

Real Cable HDD18 operating manual

Real Cable

Real Cable HDD18 operating manual

SMART GoWire GW-MP User information

SMART

SMART GoWire GW-MP User information

Arrel Audio R-601 user manual

Arrel Audio

Arrel Audio R-601 user manual

Philips SWA2700W Specifications

Philips

Philips SWA2700W Specifications

LevelOne KVM-0290 quick start guide

LevelOne

LevelOne KVM-0290 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.