C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty.
©2008 ADTRAN, Inc. All Rights Reserved.
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
*61442520G1-22A*
COMPLIANCE
♦ Electrostatic Discharge (ESD) can damage
electronic modules. When handling modules, wear
an antistatic discharge wrist strap to prevent
damage to electronic components. Place modules
in antistatic packing material when transporting
or storing. When working on modules, always
place them on an approved antistatic mat that is
electrically grounded.
♦ The SFP meets or exceeds all the applicable
requirements of NEBS, Telcordia GR-63-CORE,
and GR-1089-CORE. The SFP is intended for
deployment in Central Office type facilities, EEEs,
EECs, and locations where the NEC applies (for
example, Customer Premises). The SFP is to be
installed in ADTRAN products in Restricted Access
Locations only, and installed by trained service
personnel.
This device complies with FCC 47 CFR Part 15, Class
B. Operation is subject to the following two condi-
tions:
1. This device may not cause harmful interference.
2. This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by
ADTRAN could void the user's authority to operate
this equipment.
♦ Per GR-1089-CORE, the ADTRAN system in which
the SFP is being deployed is designed and intended
for installation as part of a Common Bonding
Network (CBN). The ADTRAN system in which the
SFP is being deployed is not designed nor intended
for installation as part of an Isolated Bonding
Network (IBN).
♦ Per GR-1089-CORE Section 9, the SFP does not
have an internal DC connection between battery
return and frame ground. The SFP can be installed
in a DC-I (isolated) or DC-C (common) installation.
For installations where other cards or the host
system have internal connections between battery
return and frame ground, the system would be
intended for deployment only in a DC-C
installation.
♦ The ADTRAN system chassis frame ground
terminal must be connected to a reliable earth
ground to ensure that the metal enclosure of the
SFP is properly grounded via the backplane
connector.
The SFP is a Class 1 Laser Product and complies with
the Laser Safety requirements of FDA 21CFR
1040.10 and 1040.11, and EN60825-1 and -2. The
SFP is NRTL listed and CB Certified to all applicable
American and European safety standards.
For continued compliance with the above laser safety
standards, only approved Class 1 modules from our
approved vendor list, located on the ADTRAN website,
should be installed in ADTRAN products.
NOTE
The Gigabit port(s) are optical and therefore are not
classified as any type of port as defined in Appendix
B of GR-1089-CORE, Issue 4.
The SFP is designed to meet the following environ-
mental classes:
♦ETSI EN 300 019-1-1 “Classification of
environmental conditions; Storage,” Class 1.2
♦ETSI EN 300 019-1-2 “Classification of
environmental conditions, Transportation,” Class
2.3
♦ETSI EN 300 019-1-3 “Classification of
environmental conditions, Stationary use at
weather-protected locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class
3.3.