DESCRIPTION
MC 740-E-M14 is a surface mounted magnetic contact used
in both alarm and security access control systems for
protection of doors and windows against unauthorised
opening. The magnetic contact is designed to be mounted in
places with limited space. The magnet part is easy to mount
with supplied rivet or screw.
CIRCUIT DIAGRAM
OPERATING PRINCIPLE
MC 740-E-M14 magnetic contact has two parts: the contact
part with a reed switch and the ring magnet part. In its
neutral position the reed switch remains closed under the
force of the magnetic field. Opening the monitored object
increases the distance between the reed switch and the
magnet. This reduces the influence of the magnetic field on
the reed switch until it opens and activates an alarm.
Magnetic contacts should not be installed in the vicinity of
strong magnetic fields.
TECHNICAL DATA
Working environment
Wood
Steel
Make distance
typ. 25 mm
not recommended
Break distance
typ. 28 mm
not recommended
Contact type
form A, SPST
Switching voltage max.
48 V DC/AC
Switching current max.
500 mA DC/peak AC
Contact rating max.
10 W
Cable
ф 3,4 mm, 4x0,182 mm2
Operating temperature range
-40°C to +70°C
Operating humidity
max. 95% RH
Housing material
plastic ABS
Dimensions:
Contact part
60 x 5 x 13,5 mm
Magnet part
Ф14 x 3,5 mm
MC 740-E-M14 Instruction Manual 4-MC740-E-M14-01
© 2021 Alarmtech Rev. MC740-E-M14_2121en Page 2of 2
INSTALLATION
Depending on the application, contact and magnet should
be installed in either front-to-front or side-to-front
configuration. Installation drawings show the correct
positioning of the contact parts. The contact should be
mounted on the stationary part of the monitored object (ex.
door frame) and the magnet on the movable part (ex. door
leaf, roller-shutter).
During installation of contact part in window or door frame,
it is advised to leave additional cable loop for about 10cm
long.
After the installation, use an ohmmeter to check the
electrical connections and test the operation of the
magnetic contact.
Warning: applying excessive force to the housing of the
contact may damage the glass body of the reed switches
inside.
Warning: installation in ferromagnetic environment is not
recommended.
INSTALLATION DRAWINGS
Correct positioning of side cable inlets ensure the maximum
working distances.
MC 740-E-M14 in front to front configuration
MC 740-E-M14 in side to front configuration
We reserve the right to changes without notice.

Other Alarmtech Security Sensor manuals

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech CD 400 User manual

Alarmtech

Alarmtech CD 400 User manual

Alarmtech MC 470 User manual

Alarmtech

Alarmtech MC 470 User manual

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech MC 140 User manual

Alarmtech

Alarmtech MC 140 User manual

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech GD 370 User guide

Alarmtech

Alarmtech GD 370 User guide

Alarmtech MC 472 User manual

Alarmtech

Alarmtech MC 472 User manual

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech CD 470-I User manual

Alarmtech

Alarmtech CD 470-I User manual

Alarmtech MC 746-E User manual

Alarmtech

Alarmtech MC 746-E User manual

Alarmtech MC 346 User manual

Alarmtech

Alarmtech MC 346 User manual

Alarmtech MC 340 2x4,7k User manual

Alarmtech

Alarmtech MC 340 2x4,7k User manual

Alarmtech AD 700 User manual

Alarmtech

Alarmtech AD 700 User manual

Alarmtech AD 800-AM Manual

Alarmtech

Alarmtech AD 800-AM Manual

Alarmtech GD 335 User manual

Alarmtech

Alarmtech GD 335 User manual

Alarmtech AD 800 Manual

Alarmtech

Alarmtech AD 800 Manual

Alarmtech GD 375 Instruction Manual

Alarmtech

Alarmtech GD 375 Instruction Manual

Popular Security Sensor manuals by other brands

STEINEL PROFESSIONAL IR Quattro DALI manual

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL IR Quattro DALI manual

König Electronic SEC-CA10 manual

König Electronic

König Electronic SEC-CA10 manual

Honeywell One FireLite Alarms SD355 Installation and maintenance instructions

Honeywell

Honeywell One FireLite Alarms SD355 Installation and maintenance instructions

F&F DR-09B-IP65 manual

F&F

F&F DR-09B-IP65 manual

Safescan 45 user manual

Safescan

Safescan 45 user manual

Velleman PIR300 manual

Velleman

Velleman PIR300 manual

ELRO FH380111R instruction manual

ELRO

ELRO FH380111R instruction manual

Theben thePrema S360-101 E UP WH quick start guide

Theben

Theben thePrema S360-101 E UP WH quick start guide

Emerson Machinery Health AMS EZ 1000 operating manual

Emerson

Emerson Machinery Health AMS EZ 1000 operating manual

LEGRAND Triscan 488TRI3W instruction manual

LEGRAND

LEGRAND Triscan 488TRI3W instruction manual

AVE AF45362 manual

AVE

AVE AF45362 manual

SECO-LARM E-931CS22RRCQ installation manual

SECO-LARM

SECO-LARM E-931CS22RRCQ installation manual

AVE LUCE AMICA 44 068/3F Series quick start guide

AVE

AVE LUCE AMICA 44 068/3F Series quick start guide

Lightcloud LCLCSENSE/M/EG/A manual

Lightcloud

Lightcloud LCLCSENSE/M/EG/A manual

Niko Swiss Garde 360 DALI Secondary A-Comfort high ceiling... installation instructions

Niko

Niko Swiss Garde 360 DALI Secondary A-Comfort high ceiling... installation instructions

Prime Controls FLUXIMITY DS71 operating instructions

Prime Controls

Prime Controls FLUXIMITY DS71 operating instructions

PASCO PS-3219 BATTERY REPLACEMENT INSTRUCTIONS

PASCO

PASCO PS-3219 BATTERY REPLACEMENT INSTRUCTIONS

Niko 350-20085 manual

Niko

Niko 350-20085 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.