MC 740-E-M14 Instruction Manual 4-MC740-E-M14-01
© 2021 Alarmtech Rev. MC740-E-M14_2121en Page 1of 2
Detectors
Magnetic Contact
Surface mounting
Instruction Manual MC 740-E-M14
DESCRIPTION
MC 740-E-M14 is a surface mounted magnetic contact used
in both alarm and security access control systems for
protection of doors and windows against unauthorised
opening. The magnetic contact is designed to be mounted in
places with limited space. The magnet part is easy to mount
with supplied rivet or screw.
CIRCUIT DIAGRAM
OPERATING PRINCIPLE
MC 740-E-M14 magnetic contact has two parts: the contact
part with a reed switch and the ring magnet part. In its
neutral position the reed switch remains closed under the
force of the magnetic field. Opening the monitored object
increases the distance between the reed switch and the
magnet. This reduces the influence of the magnetic field on
the reed switch until it opens and activates an alarm.
Magnetic contacts should not be installed in the vicinity of
strong magnetic fields.
TECHNICAL DATA
Working environment
Wood
Steel
Make distance
typ. 25 mm
not recommended
Break distance
typ. 28 mm
not recommended
Contact type
form A, SPST
Switching voltage max.
48 V DC/AC
Switching current max.
500 mA DC/peak AC
Contact rating max.
10 W
Cable
ф 3,4 mm, 4x0,182 mm2
Operating temperature range
-40°C to +70°C
Operating humidity
max. 95% RH
Housing material
plastic ABS
Dimensions:
Contact part
60 x 5 x 13,5 mm
Magnet part
Ф14 x 3,5 mm
MC 740-E-M14 Instruction Manual 4-MC740-E-M14-01
© 2021 Alarmtech Rev. MC740-E-M14_2121en Page 2of 2
INSTALLATION
Depending on the application, contact and magnet should
be installed in either front-to-front or side-to-front
configuration. Installation drawings show the correct
positioning of the contact parts. The contact should be
mounted on the stationary part of the monitored object (ex.
door frame) and the magnet on the movable part (ex. door
leaf, roller-shutter).
During installation of contact part in window or door frame,
it is advised to leave additional cable loop for about 10cm
long.
After the installation, use an ohmmeter to check the
electrical connections and test the operation of the
magnetic contact.
Warning: applying excessive force to the housing of the
contact may damage the glass body of the reed switches
inside.
Warning: installation in ferromagnetic environment is not
recommended.
INSTALLATION DRAWINGS
Correct positioning of side cable inlets ensure the maximum
working distances.
MC 740-E-M14 in front to front configuration
MC 740-E-M14 in side to front configuration
We reserve the right to changes without notice.

Other Alarmtech Security Sensor manuals

Alarmtech GD 375 Instruction Manual

Alarmtech

Alarmtech GD 375 Instruction Manual

Alarmtech MC 470 User manual

Alarmtech

Alarmtech MC 470 User manual

Alarmtech MC 340 2x4,7k User manual

Alarmtech

Alarmtech MC 340 2x4,7k User manual

Alarmtech AD 800 Manual

Alarmtech

Alarmtech AD 800 Manual

Alarmtech MC 472 User manual

Alarmtech

Alarmtech MC 472 User manual

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech CD 470-I User manual

Alarmtech

Alarmtech CD 470-I User manual

Alarmtech CD 400 User manual

Alarmtech

Alarmtech CD 400 User manual

Alarmtech GD 370 User guide

Alarmtech

Alarmtech GD 370 User guide

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech AD 800-AM Manual

Alarmtech

Alarmtech AD 800-AM Manual

Alarmtech MC 140 User manual

Alarmtech

Alarmtech MC 140 User manual

Alarmtech MC 746-E User manual

Alarmtech

Alarmtech MC 746-E User manual

Alarmtech AD 700 User manual

Alarmtech

Alarmtech AD 700 User manual

Alarmtech MC 346 User manual

Alarmtech

Alarmtech MC 346 User manual

Alarmtech MC 740-E User manual

Alarmtech

Alarmtech MC 740-E User manual

Alarmtech CD 470 User manual

Alarmtech

Alarmtech CD 470 User manual

Alarmtech GD 335 User manual

Alarmtech

Alarmtech GD 335 User manual

Popular Security Sensor manuals by other brands

THORLABS SPDMA Operation manual

THORLABS

THORLABS SPDMA Operation manual

Infinite L-COM SRMS-D469-1 user guide

Infinite

Infinite L-COM SRMS-D469-1 user guide

Baumer UNAM 50U6121 manual

Baumer

Baumer UNAM 50U6121 manual

Endress+Hauser USR30 technical information

Endress+Hauser

Endress+Hauser USR30 technical information

Clas Ohlson TSM02 quick start guide

Clas Ohlson

Clas Ohlson TSM02 quick start guide

Uniden R3 user manual

Uniden

Uniden R3 user manual

teko Astra-516 operating manual

teko

teko Astra-516 operating manual

hyfire HFW-MA-05 instructions

hyfire

hyfire HFW-MA-05 instructions

Protean Instrument MPC-900 manual

Protean Instrument

Protean Instrument MPC-900 manual

Assa Abloy Ditec PAS005AP user guide

Assa Abloy

Assa Abloy Ditec PAS005AP user guide

DMP Electronics 1121 Installation sheet

DMP Electronics

DMP Electronics 1121 Installation sheet

IFM Electronic EFECTOR 500 PD70 Series operating instructions

IFM Electronic

IFM Electronic EFECTOR 500 PD70 Series operating instructions

Rielta Pyrone-7i installation guide

Rielta

Rielta Pyrone-7i installation guide

STI 7535MED Quick installation

STI

STI 7535MED Quick installation

AQUALEAK AquaGuard Dual instruction manual

AQUALEAK

AQUALEAK AquaGuard Dual instruction manual

General Monitors FL3112 manual

General Monitors

General Monitors FL3112 manual

Falltech EcoAnchor user manual

Falltech

Falltech EcoAnchor user manual

WABCO 400 606 410 0 user manual

WABCO

WABCO 400 606 410 0 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.