MC 740-E-M14 Instruction Manual 4-MC740-E-M14-01
© 2021 Alarmtech Rev. MC740-E-M14_2121en Page 2of 2
INSTALLATION
Depending on the application, contact and magnet should
be installed in either front-to-front or side-to-front
configuration. Installation drawings show the correct
positioning of the contact parts. The contact should be
mounted on the stationary part of the monitored object (ex.
door frame) and the magnet on the movable part (ex. door
leaf, roller-shutter).
During installation of contact part in window or door frame,
it is advised to leave additional cable loop for about 10cm
long.
After the installation, use an ohmmeter to check the
electrical connections and test the operation of the
magnetic contact.
Warning: applying excessive force to the housing of the
contact may damage the glass body of the reed switches
inside.
Warning: installation in ferromagnetic environment is not
recommended.
INSTALLATION DRAWINGS
Correct positioning of side cable inlets ensure the maximum
working distances.
MC 740-E-M14 in front to front configuration
MC 740-E-M14 in side to front configuration