Ambu aScope 3 User manual

2.
3.
Connecting the system
Preparation for use
Turn the page
Ambu®aScope™3 and Ambu®aScope™3 Slim
- Quick Guide for intubation and single lung ventilation
The aScope  and aScope  Slim are the perfect choice
for all types of intubation as they are ready to use
whenever you need them. The instantly accessible
single-use and ready-to-go concept simplify exible
intubation procedures and improve patient safety.
aScope  and aScope  Slim are single-use sterile
exible videoscopes with a . mm or . mm working
channel respectively.
For intubation the aScope  can be used with ET tubes size
 and up and the aScope  Slim with ET tubes size  and up.
For single lung ventilation aScope  Slim can be passed
through DLT’s of FR  or greater or BB of sizes .
•Ensure that the selected ET tube or DLT/BB is compatible with
the aScope  or aScope  Slim.
•Lubricate the insertion cord with a medical grade lubricant to
ensure the lowest possible friction. Do not get lubrication or any
other contaminant on the tip of the aScope /aScope Slim.
•Attach the suction tube to the suction connector and ensure
that the suction works when pressing the suction button
•Fluids can be instilled through the working channel by inserting a
syringe into the working channel port at the top of the aScope .
When using a Luer Lock syringe, use the included introducer.
•If you are using a preformed ET tube unbend it before inserting
the cord of the aScope through it.
•Antifogging agent is not required with this device.
•Conrm that the bending section functions smoothly and
correctly by carefully sliding the bending control lever forward
and backward in each direction.
•Conrm that the bending section returns to a straight position.
•Connect the aScope /aScope Slim to the aView and verify that
a live video image appears on the screen.
•Always have an additional aScope at hand as a precaution.
1. Functions
Warning: Read Instructions For Use before using the aScope™3 or aScope™3 Slim and aView.
. & . Connect aScope 3 or aScope 3 Slim to the
aView by plugging the aScope 3 connector
- white with blue arrow - into the corresponding
blue female connector on the side of aView.
. Push the ON/OFF
button on the aView to
start up the system.
. The real time image
will appear on aView
after only a few seconds
and the aScope system
is ready to use
aScope 3
Insertion cord diameter 5.0 mm
Working channel 2.2 mm
Bending angle 150º/130º
aScope 3 Slim
Insertion cord diameter 3.8 mm
Working channel 1.2 mm
Bending angle 130º/130º
6.
7.
Insertion of the aScope 3& aScope 3Slim
Removal procedure
•
Slowly withdraw the aScope while observing the image on the monitor.
The distal tip must be in a neutral and non-deflected position.
•
After use disconnect the aScope from the aView and dispose of it in accordance with
local guidelines for collection of infected medical devices with electronic components.
•
Wipe down the aView as per the instructions in the Instructions For Use.
•
The tube connection can be used to fixate
the selected ET tube during intubation.
•
Keep the cord of the aScope or
aScope Slim as straight as possible by
holding the handle of the aScope high.
This increases the range of movement of
the tip and allows you more control.
•
Advance the aScope or aScope Slim
slowly, allowing the light intensity of the
image to re-adjust.
•
If the image is affected by blood or
secretion you can try to clear the
secretion by flicking the bending lever up
and down or dabbing the camera tip
gently against the mucosal wall to clear
the image.
•
If the above fails, remove the aScope and
rub the lens clean with either gauze or an
alcohol swap.
Do not be afraid to exert a little pressure
when doing this. Proceed as above.
Ambu A/S
Baltorpbakken  • DK- Ballerup • Denmark
T +     • F +    
www.ambu.com
496 3603 01 - V01 - 2013/09 - Ambu A/S. Technical data may be modied without further notice.
•
The aView can be placed on a flat surface or secured to an I.V. pole using the
bracket supplied. The bracket also has a hook that facilitates easy, accessible
storage of the aScope via the hole in the top of the aScope /aScope Slim pouch.
•
Most users find the default contrast and brightness settings to be optimal but
these can be adjusted if required.
•
Consider dimming the room lights to see the image from the aScope or
aScope Slim more clearly.
•
Check the battery indicator on the aView.
If the time remaining is not sufficient for the procedure charge the monitor by
plugging it into the mains.
4.
5.
Preparation for use
Icons
Max. battery status
of the aView
Min. battery status
of the aView
The icon remains white until one block is
left, after which it turns red.
When remaining battery capacity is %
the red battery icon starts ashing.
Charging is shown with blocks ashing.
Current capacity is shown with non-
ashing blocks.
Battery is charging Battery current
capacity
If the battery is fully charged and still
connected to a charger the battery
icon changes to:
Start-up picture
Real time image will
appear after only a
few seconds.
After appr.  seconds
the user Interface is
ready displaying the
icons for battery status,
brightness/contrast
control, device usage
time as well as the as
snapshots and
recording of videos.
When the aView is
turned on the ON/OFF
button will light up
green. During charging
the ON/OFF button will
light orange.

This manual suits for next models

1

Other Ambu Medical Equipment manuals

Ambu aBox 2 User manual

Ambu

Ambu aBox 2 User manual

Ambu aScope Duodeno User manual

Ambu

Ambu aScope Duodeno User manual

Ambu aScope 2 User manual

Ambu

Ambu aScope 2 User manual

Ambu aScope 3 5.0/2.2 User manual

Ambu

Ambu aScope 3 5.0/2.2 User manual

Ambu VivaSight 2 DLT User manual

Ambu

Ambu VivaSight 2 DLT User manual

Ambu aScope 5 User manual

Ambu

Ambu aScope 5 User manual

Ambu Aura-i User manual

Ambu

Ambu Aura-i User manual

Ambu aScope 4 RhinoLaryngo Slim User manual

Ambu

Ambu aScope 4 RhinoLaryngo Slim User manual

Ambu AmbuMan Operating instructions

Ambu

Ambu AmbuMan Operating instructions

Ambu aBox 2 User manual

Ambu

Ambu aBox 2 User manual

Ambu Perfit ACE Manual

Ambu

Ambu Perfit ACE Manual

Ambu AuraStraight User manual

Ambu

Ambu AuraStraight User manual

Ambu King Mask User manual

Ambu

Ambu King Mask User manual

Ambu Mini Perfit ACE User manual

Ambu

Ambu Mini Perfit ACE User manual

Ambu BronchoSampler 60 User manual

Ambu

Ambu BronchoSampler 60 User manual

Ambu aScope 4 Broncho Series User manual

Ambu

Ambu aScope 4 Broncho Series User manual

Ambu Cuff Pressure Gauge User manual

Ambu

Ambu Cuff Pressure Gauge User manual

Ambu aScope 4 Broncho Series User manual

Ambu

Ambu aScope 4 Broncho Series User manual

Ambu AmbuMan Manual

Ambu

Ambu AmbuMan Manual

Ambu aScope Gastro User manual

Ambu

Ambu aScope Gastro User manual

Ambu Oval Plus Neonate User manual

Ambu

Ambu Oval Plus Neonate User manual

Ambu Redi-ACE Adult User manual

Ambu

Ambu Redi-ACE Adult User manual

Ambu Redi-ACE Adult User manual

Ambu

Ambu Redi-ACE Adult User manual

Ambu Oval Plus User manual

Ambu

Ambu Oval Plus User manual

Popular Medical Equipment manuals by other brands

Itamar Medical WatchPAT Operation manual

Itamar Medical

Itamar Medical WatchPAT Operation manual

PROTEOR 1P650 KNEE Assembling and adjustment instructions

PROTEOR

PROTEOR 1P650 KNEE Assembling and adjustment instructions

Liberate Medical VentFree user manual

Liberate Medical

Liberate Medical VentFree user manual

Dicarre DA20 user guide

Dicarre

Dicarre DA20 user guide

Stryker Medical M Series Operation manual

Stryker Medical

Stryker Medical M Series Operation manual

Invacare ScanBed 750 user manual

Invacare

Invacare ScanBed 750 user manual

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Getinge

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics Sonicator 730 Maintenance manual

Mettler Electronics

Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care R1100 Mounting instruction

Pressalit Care

Pressalit Care R1100 Mounting instruction

Denas MS DENAS-T operating manual

Denas MS

Denas MS DENAS-T operating manual

bort medical ActiveColor quick guide

bort medical

bort medical ActiveColor quick guide

AccuVein AV400 user manual

AccuVein

AccuVein AV400 user manual

agiliti NP Trio user manual

agiliti

agiliti NP Trio user manual

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Rocket Medical

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Monteris Medical Neuroblate Instructions for use

Monteris Medical

Monteris Medical Neuroblate Instructions for use

Otto Block 8E33 7 manual

Otto Block

Otto Block 8E33 7 manual

ADVANCED HOME CARE Helios Guide

ADVANCED HOME CARE

ADVANCED HOME CARE Helios Guide

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.