5
B. SPECIFICATIONS OF CONCRETE (See Fig. 6)
Specifications of concrete must be adhered to the specification as following.
Failure to do so may result in lift and/or vehicle falling.
1. Concrete must be thickness 4” minimum and without reinforcing steel bars, and
must be completely dry before lift installation.
2. Concrete must be in good condition and must be of test strength 3,000psi
minimum.
3. Floors must be level with no cracks or holes.
C. POWER SUPPLY
The electrical source must be 2.0HP minimum. The source cable size must be
2.5mm2and in good condition of contacting with floor.
III.INSTALLATION STEPS
A. Location of installation
Check and ensure the installation location (concrete, layout, space size etc.) is
suitable for lift installation.
B. Use a carpenter’s chalk line to establish installation layout of base-plate (See Fig. 7).
Concrete intensity must be 3,000psi
HS-10/HS-10H installation diagram