manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Arjo
  6. •
  7. Medical Equipment
  8. •
  9. Arjo 2000 Rhapsody User manual

Arjo 2000 Rhapsody User manual

Preparations
6 8
!4
1!23
Bathe patient with lift hygiene chair
7
9
5
10
Lower the bathtub to its lowest
height.
Close the drain.Bathing with hygiene chair: attach the head pillow.
Bathing with bath trolley: do not attach the head
pillow or foot support.
Centre chair over the bathtub until it
stops against the bathtub legs and rim.
Let the patient feel the water
with their foot.
Adjust temperature if needed.
Adjust the lift hygiene chair to an ergonomic hight for the caregiver.
Raise the bathtub. Make sure that there is enough space between the
patient’s genitals and the bottom of the bathtub.
Position lift hygiene chair
diagonally to the side of the bath.
Attach foot support if needed.
Bathe the patient.
Move the lift hygiene chair towards the
bath. Lift the patient legs over the bathtub
rim while rotating the lift into place.
Risk of
entrapment
Risk of scalding
Risk of
pinching
Risk of
pinching
11
Press the Autofill button. Check the
water temperature with a bare hand.
Adjust temperature if needed.
6
Bathe patient with lift bath trolley
Adjust the lift bath trolley to an ergonomic hight for the caregiver.
Raise the bathtub until the stretcher is touching the bottom of the bathtub.
Raise the lift hygiene chair enough
to give space between the patient’s
genitals and the bathtub rim.
Position the lift bath trolley behind
and to the side of the bath.
Raise the lift bath trolley stretcher
enough to clear the edge of the bathtub.
Move the lift bath trolley with patient
diagonally in over the bathtub rim.
Centre the trolley until it stops
against the bathtub legs and rim.
6
12 13 14 15
16 17
Attach foot support if needed.
Bathe the patient.
08.AR.08_1EN • 09/2020 • Page 1/2
QUICK REFERENCE GUIDE - USE
System 2000 Rhapsody, Primo, Harmonie
Hydromassage (optional)
7
Hydrosound (optional)
Install the suction cover
before use.
Fill up with water to cover the
Hydromassage system outlet
(A) and top sensor (B).
Adjust the direction
of the water-jet.
Press the Hydrosound system
button. The default runtime is
15 minutes.
Risk of
entrapment A
B
After treatment,
turn off the
Hydromassage
system.
After treatment, press the Hydromassage
system button to turn the Hydromassage
system off.
Never use
when pregnant.
Risk of
burns and
hearing
damage.
Do not touch the Transducer
Plate and keep patients
head above water.
Fill up with water to cover the
Hydrosound system Transducer Plate.
Add Hydrosoundwater conditioner.
Shower the patient
7
Open the drain. Raise the back rest. Let the
patient hold on to the hand rest.
Take the shower handle. Press the shower
button. Direct the shower handle away from
the patient.
Unlock the shower handle trigger if
lock button is activated.
Press the shower button.
Return the shower handle.
Let the patient feel the water by hand
before directing the water stream on the
patient. Adjust temperature if needed.
Risk of scalding
Shower the patient.
Press the trigger on the shower handle.
Check the water temperature with a bare
hand. Adjust temperature if needed.
Lower the bathtub to its lowest height.
+
-
After treatment,
turn off the
Hydrosound
system.
Adjust the
Hydrosound intensity.
20
P300
P220
End the bath
Dry the patient. Keep the patient warm using
towels or a bathrobe.
Lower the bathtub to its lowest height.
Risk of
pinching
Raise the lift hygiene chair enough to give space
between the patient’s genitals and the bathtub rim.
Help the patient to move the legs over the rim
while rotating the lift away from the bathtub.
Make sure there is enough space between
the bathtub side and lift hygiene chair.
Lower the lift hygiene chair.
Dry the remaining wet areas.
18 19 20 21
22 23 24 25
26 27 28 29
30 31 32
Press the Hydromassage system button.
The default runtime is 15 minutes.
Start with low intensity. Adjust if needed.
After each patient:
clean and disinfect the
bathtub according to
the instructions in the
IFU or Cleaning and
disinfection QRG.
33
Risk of contamination
ArjoHuntleigh AB
Hans Michelsensgatan 10
211 20 Malmö, Sweden
www.arjo.com 08.AR.08_1EN • 09/2020 • Page 2/2

Other manuals for 2000 Rhapsody

1

This manual suits for next models

2

Other Arjo Medical Equipment manuals

Arjo Enterprise ENT-ACC32 User manual

Arjo

Arjo Enterprise ENT-ACC32 User manual

Arjo Huntleigh Sonicaid Team3 USA User manual

Arjo

Arjo Huntleigh Sonicaid Team3 USA User manual

Arjo Prioma User manual

Arjo

Arjo Prioma User manual

Arjo AtmosAir Velaris - Plus Flex User manual

Arjo

Arjo AtmosAir Velaris - Plus Flex User manual

Arjo Flowtron ACS900 User manual

Arjo

Arjo Flowtron ACS900 User manual

Arjo Enterprise ENT-ACC02 User manual

Arjo

Arjo Enterprise ENT-ACC02 User manual

Arjo Evenda EV-ACC01 User manual

Arjo

Arjo Evenda EV-ACC01 User manual

Arjo Maxi Sky 2 User manual

Arjo

Arjo Maxi Sky 2 User manual

Arjo Alpha Active 4 User manual

Arjo

Arjo Alpha Active 4 User manual

Arjo Prioma User manual

Arjo

Arjo Prioma User manual

Arjo Maxi Sky 1000 User manual

Arjo

Arjo Maxi Sky 1000 User manual

Arjo Miranti User manual

Arjo

Arjo Miranti User manual

Arjo MAA4000-M User manual

Arjo

Arjo MAA4000-M User manual

Arjo Flowtron Excel User manual

Arjo

Arjo Flowtron Excel User manual

Arjo Enterprise 9600X User manual

Arjo

Arjo Enterprise 9600X User manual

Arjo Prioma Couch Electric User manual

Arjo

Arjo Prioma Couch Electric User manual

Arjo Tenor Installation guide

Arjo

Arjo Tenor Installation guide

Arjo Maxi Sky 440 User manual

Arjo

Arjo Maxi Sky 440 User manual

Arjo Auralis User manual

Arjo

Arjo Auralis User manual

Arjo Skin IQ 1000 User manual

Arjo

Arjo Skin IQ 1000 User manual

Arjo Huntleigh Dopplex Ability User manual

Arjo

Arjo Huntleigh Dopplex Ability User manual

Arjo Maxi Sky 2 User manual

Arjo

Arjo Maxi Sky 2 User manual

Arjo Evenda EV-ACC07 User manual

Arjo

Arjo Evenda EV-ACC07 User manual

Arjo Auralis User manual

Arjo

Arjo Auralis User manual

Popular Medical Equipment manuals by other brands

HEBU medical HB 0181-06 operating manual

HEBU medical

HEBU medical HB 0181-06 operating manual

MIHM-VOGT MV-R 100/120 operating manual

MIHM-VOGT

MIHM-VOGT MV-R 100/120 operating manual

Posey 2510 quick start guide

Posey

Posey 2510 quick start guide

Drive Check and Go operating manual

Drive

Drive Check and Go operating manual

ADT Health Fall Detection Pendant user guide

ADT

ADT Health Fall Detection Pendant user guide

C-Pro Direct ADM Instructions for use

C-Pro Direct

C-Pro Direct ADM Instructions for use

Lazurite ArthroFree Instructions for use

Lazurite

Lazurite ArthroFree Instructions for use

Liko Original HighBack Sling 200 Instruction guide

Liko

Liko Original HighBack Sling 200 Instruction guide

Joerns Healthcare Full Back Disposable Sling user guide

Joerns Healthcare

Joerns Healthcare Full Back Disposable Sling user guide

3B Medical Luna GII Quick operation manual

3B Medical

3B Medical Luna GII Quick operation manual

Mindray DPM 1 Operator's manual

Mindray

Mindray DPM 1 Operator's manual

Villa Sistemi Medicali ENDOS AC user manual

Villa Sistemi Medicali

Villa Sistemi Medicali ENDOS AC user manual

Pedicraft Stay Safe Bed Operation manual

Pedicraft

Pedicraft Stay Safe Bed Operation manual

Augustine Surgical HotDog B270 Instructions for use

Augustine Surgical

Augustine Surgical HotDog B270 Instructions for use

SSCOR S-SCORT new-Sentinel 2315 OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

SSCOR

SSCOR S-SCORT new-Sentinel 2315 OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

MesMed MM-155 user manual

MesMed

MesMed MM-155 user manual

Barco Coronis Fusion 4MP user guide

Barco

Barco Coronis Fusion 4MP user guide

ElectroCore gammaCore-S instruction manual

ElectroCore

ElectroCore gammaCore-S instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.