Return to function mode
The activation of the loops can only be simulated if loops are connected to the appropriate terminal!
The displays apply similarly for loop 2
If an error occurs, operating mode «A» and error display « » light up alternately and an error code such as 012 is displayed. The L D changes to flashing
red, the 4 most recent errors are stored and can be interrogated.
Disp ay 001 002 011 012 101 201 301 302 311 312
Error Interruption
Loop 1
Interruption
Loop 2
Short circuit
Loop 1
Short circuit
Loop 2
Under-
voltage
PROM
rror
Loop 1
too large
Loop 2
too large
Loop 1
too small
Loop 2
too small
Briefly pressing the «Data» button shows the last of 4 errors on the display. Another short press switches to the error before that,
and so on. When the button is pressed for the 5th time, the device switches back to automatic mode. If you press the «Data» button
for 2 seconds during the query, all error messages are deleted. The figure shows memory slot 1 in which error 001 Interruption loop
1 has been stored (example).
P oLoop P oLoop 11
Supply voltage /
Power consumption
24 VAC –20 % to +10%, max. 2 VA
24 VDC –10 % to +20%, max. 1.5 W
94–240 VAC ± 10%, 50/60, max. 2.9 VA
24 VAC –20% to +10%, max. 1.8 VA
24 VDC –10% to +20%, max. 1.3 W
115 VAC –15% to +10%, max. 3.5 VA
230 VAC –15% to +10%, max. 3.7 VA
Power consumption max. 2 VA 24V 1.2 VA
Loop inductance max. 40–1000 µH,
ideally 80–300 µH
max. 40–1000 µH,
ideally 80–300 µH
Loop connection wiring max. 200 m 1,5 mm2
min. 20x/m
max. 200 m 1,5 mm2
min. twisted 20x/m
Loop resistance < 8 Ohm with connection wire < 8 Ohm with connection wire
Output relay (loop) 240 VAC/2 A AC1 240 VAC/2 A AC1
Output relay (alarm) 60 VAC, 0.3 A, AC1 –
Dimensions 22.5 x 94 x 88 mm (W x H x D) 36 x 74 x 88 mm (W x H x D)
Housing mounting Direct DIN rail mounting Mounting rail installation via 11-pin base S 12
Connection type Plug-in terminals Screw terminals base S 12
Protection class IP 30 IP 20
Approvals, safety See declaration of conformity at www.bircher-reglomat.com See declaration of conformity at www.bircher-reglomat.com
Operating temperature –20°C to +60°C –20°C to +60°C
Storage temperature –40°C to +70°C –40°C to +70°C
Air humidity <95% non-condensing <95% non-condensing
Manufacturer: Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen declares that the
Product, type: ProLoop, ProLoop 11
Model: 24VDACDC, 115VAC, 230VAC, 1-loop devices, 2-loop devices
Intended purpose: Programmable loop detector for controlling gates and barriers as well as for regulating and counting cars in parking areas
if used in accordance with the intended purpose, complies with the basic requirements acc. to:
R&TT Directive, Appendix III 1999/5/ C
263677F06/10
5Simu ation mode
6Troub eshooting
7Reset
8Most important technica data
9Dec aration of conformity
10 Contact data