4
red LED green LED Fault Remedy
not
illuminated
continuously
lit
Radar tripping when door is closing 1. Set angle of radar further away from the door.
2. Adjust radar eld size.
Radar false tripping without
apparent external inuence
1. Avoid light sources (e.g. uorescent tubes) in the immediate vicinity of the detector.
2. No moving objects (plants, advertising posters, etc.) in the vicinity of the detector.
3. Avoid strong vibration at the radar detector
4. Possible inuence from a second radar detector in the vicinity (very unlikely)
continuously
lit
not
illuminated
AIR tripping when door is closing 1. Set angle of AIR detector further away from the door
AIR false tripping without apparent
external inuence
1. Avoid light sources (e.g. uorescent tubes) in the immediate vicinity of the detector.
2. Avoid puddles of water on the ground.
3. Avoid strong vibration at the AIR detector.
4. Inuence of overlapping AIR eld from another detector.
Set new Reglobeam address or CAN bus address.
5. Reduce sensitivity of the AIR (increase value).
not
illuminated
not
illuminated Door stays open 1. Switch AIR exit contact logic to other value
7Remedying malfunctions
8Technical data
9Declaration of conformity, identication of the year of manufacture by means of the serial number
7.1 Remedying false tripping
7.2 Remedying detector malfunctions
9.1 Declaration of conformity
red LED green LED Fault Remedy
ashing ashing
11: Self test (RAM/ROM)
2: Watchdog
1. Disconnect device from supply voltage
2. Restart device
3. If device displays fault again or does not start ➔renew device
ashing not
illuminated
25: AIR fault
6: AIR output fault
1. Disconnect device from supply voltage
2. Clean optics-cover and check for scratches
3. Restart device
4. If device displays fault again or does not start ➔renew device
Manufacturer: Bircher Reglomat AG, Wiesengasse 20, CH-8222 Beringen
Authorised rep: Bircher Reglomat GmbH, Robert Bosch Strasse 3, D-71088 Holzgerlingen
Following directives have been observed: Manchinery directive 2006/42/EC, RoHS-Directive 2011/65/EU,
R&TTE-Directive 1999/5/EC until 12.06.2016, RED 2014/53/EU starting 13.06.2016,
EMC-Directive 2004/108/EC until 19.04.2016, EMC-Directive 2014/30/EU starting 20.04.2016
Following standards have been taken into account: EN16005:2012, BS7036-1:1996, BS7036-2:1996, EN ISO 13849-1:2008, EN12978:2003+A1:2009
EC type-examination certicate: 44/205/12/403013-003
Notied inspection centre: TÜV NORD CERT, NB 0044
Signee: Head of Sales & Marketing Damian Grand / Head of Operations Daniel Nef
Product variant: PrimeTec B ES, PrimeTec B ES/01, PrimeTec B ES/02, PrimeScan B
Technology Active infrared (wavelength: 880nm), radar double eld module ➔ PrimeTec (24.125 GHz)
Number of IR spots 24
IR spot dimensions 3 cm x 3 cm (at 2.2 m mounting height)
Response time < 200 ms
Mounting height 1.8 - 4 m
Angle setting of IR spots – 5° ... + 7° continuously adjustable
Power Supply ≤ 120 mA @ 11.5 ... 32 VDC
Power consumption < 4 Watt
Making current ≤ 240 mA
Output (AIR / Radar) Semiconductor relay: max. contact voltage 24 VAC / 34 VDC, max. contact resistance: 10 Ω
max. load current 40 mA, max switching capacity:
500 mW (AC) / 500 mW (DC)
Protection type Suitable for use acc. to IP54
Operating temperature -20° ... 60° C
Dimensionsn PrimeTec: 260 x 60 x 48.5mm (LxWxD), PrimeScan: 216 x 60 x 47.5mm (LxWxD)
Weight PrimeTec: 250g, PrimeScan: 180g
Estimated economic life-time 20 years
Manufacturer
Bircher Reglomat AG
Wiesengasse 20
CH-8222 Beringen
www.bircher-reglomat.com
Contact10
Identication of the year of manufacture
9.2
Year of manufacture
Week