manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cardinal Health
  6. •
  7. Medical Equipment
  8. •
  9. Cardinal Health Kangaroo ePump User manual

Cardinal Health Kangaroo ePump User manual

Other Cardinal Health Medical Equipment manuals

Cardinal Health Kangaroo Omni 385400 User manual

Cardinal Health

Cardinal Health Kangaroo Omni 385400 User manual

Cardinal Health InPower User manual

Cardinal Health

Cardinal Health InPower User manual

Cardinal Health InPower User manual

Cardinal Health

Cardinal Health InPower User manual

Cardinal Health NPWT PRO User manual

Cardinal Health

Cardinal Health NPWT PRO User manual

Cardinal Health Kangaroo Connect Enteral Feeding Pump Manual

Cardinal Health

Cardinal Health Kangaroo Connect Enteral Feeding Pump Manual

Cardinal Health SVED NPWT User manual

Cardinal Health

Cardinal Health SVED NPWT User manual

Cardinal Health Kangaroo User manual

Cardinal Health

Cardinal Health Kangaroo User manual

Cardinal Health ALLY User manual

Cardinal Health

Cardinal Health ALLY User manual

Cardinal Health SVED PW596 User manual

Cardinal Health

Cardinal Health SVED PW596 User manual

Cardinal Health Cordis RAILWAY User manual

Cardinal Health

Cardinal Health Cordis RAILWAY User manual

Cardinal Health Alaris GW Operating manual

Cardinal Health

Cardinal Health Alaris GW Operating manual

Cardinal Health NPWT PRO User manual

Cardinal Health

Cardinal Health NPWT PRO User manual

Cardinal Health NPWT PRO User manual

Cardinal Health

Cardinal Health NPWT PRO User manual

Cardinal Health KANGAROO JOEY Installation guide

Cardinal Health

Cardinal Health KANGAROO JOEY Installation guide

Cardinal Health Kangaroo Joey Instruction Manual

Cardinal Health

Cardinal Health Kangaroo Joey Instruction Manual

Cardinal Health Kangaroo Joey User manual

Cardinal Health

Cardinal Health Kangaroo Joey User manual

Cardinal Health Kangaroo Connect User manual

Cardinal Health

Cardinal Health Kangaroo Connect User manual

Cardinal Health Kendall SCD 700 User manual

Cardinal Health

Cardinal Health Kendall SCD 700 User manual

Cardinal Health CATALYST User manual

Cardinal Health

Cardinal Health CATALYST User manual

Cardinal Health Kangaroo ePump User manual

Cardinal Health

Cardinal Health Kangaroo ePump User manual

Cardinal Health Alaris PK Manual

Cardinal Health

Cardinal Health Alaris PK Manual

Cardinal Health Infant Flow SiPAP User manual

Cardinal Health

Cardinal Health Infant Flow SiPAP User manual

Cardinal Health Kangaroo ePump User manual

Cardinal Health

Cardinal Health Kangaroo ePump User manual

Cardinal Health Kangaroo Joey User manual

Cardinal Health

Cardinal Health Kangaroo Joey User manual

Popular Medical Equipment manuals by other brands

Itamar Medical WatchPAT Operation manual

Itamar Medical

Itamar Medical WatchPAT Operation manual

PROTEOR 1P650 KNEE Assembling and adjustment instructions

PROTEOR

PROTEOR 1P650 KNEE Assembling and adjustment instructions

Liberate Medical VentFree user manual

Liberate Medical

Liberate Medical VentFree user manual

Dicarre DA20 user guide

Dicarre

Dicarre DA20 user guide

Stryker Medical M Series Operation manual

Stryker Medical

Stryker Medical M Series Operation manual

Invacare ScanBed 750 user manual

Invacare

Invacare ScanBed 750 user manual

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Getinge

Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics Sonicator 730 Maintenance manual

Mettler Electronics

Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care R1100 Mounting instruction

Pressalit Care

Pressalit Care R1100 Mounting instruction

Denas MS DENAS-T operating manual

Denas MS

Denas MS DENAS-T operating manual

bort medical ActiveColor quick guide

bort medical

bort medical ActiveColor quick guide

AccuVein AV400 user manual

AccuVein

AccuVein AV400 user manual

agiliti NP Trio user manual

agiliti

agiliti NP Trio user manual

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Rocket Medical

Rocket Medical Rocket Digital Oocyte Aspiration Pump Service manual

Monteris Medical Neuroblate Instructions for use

Monteris Medical

Monteris Medical Neuroblate Instructions for use

Otto Block 8E33 7 manual

Otto Block

Otto Block 8E33 7 manual

ADVANCED HOME CARE Helios Guide

ADVANCED HOME CARE

ADVANCED HOME CARE Helios Guide

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

© 2017 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal
Health LOGO are trademarks of Cardinal Health and may be registered in the
US and/or in other countries. 12/2017 - H9816 - WF#2098279
15 Hampshire Street 800.962.9888
Mansfield, MA 02048 508.261.8000
SYMPTOM PROBABLE CAUSE CORRECTIONS
Hold Error Pump in Holding mode for more
than 10 minutes.
Press Continue to return to Holding screen, or press and hold the
Power button to turn off. Several options are available from the
Holding screen, such as Run or Adjust Settings.
Flow Error Occlusion in pump-patient
line (downstream occlusion).
Check for and correct the occlusion in the line between pump and
patient. Replace Pump Set if error can’t be resolved.
Feed Error
Empty bag or occlusion
in bag-pump line
(upstream occlusion).
Check for empty bag and refill, or check for and correct the occlusion
in the line between the pump and feed bag. Replace Pump Set if error
can’t be resolved. Check the valve pocket in the pump set loading area
for dampness or dirt.
Pump Set
Use >24 Hrs
Pump Set in use beyond
recommended length of time.
Informational warning message blinks on upper left of screen. It’s
recommended that the Pump Set be replaced.
Pump Set
Dislodged
Pump Set not properly
loaded to pump.
Check black ring retainer (MISTIC) and valve; reload Pump Set and
restart pump to continue. Replace Pump Set if error can’t be resolved.
Battery Low Battery charge too low. Immediately plug pump into A/C outlet to recharge battery and
provide power for pump.
Rotor Error
Pump Set tubing not properly
loaded on rotor, or other unusual
rotor operating condition.
Check that the tubing is loaded on the rotor and that it’s not
damaged, torn, etc. Reload tubing or replace Pump Set.
System Error General error caused by many
factors. See Manual for error list.
Power down pump and attempt restart to clear error. Call customer
service at 800.962.9888 with screen code if error can’t be resolved.
Programming and Menu
Selection Buttons
Status LEDs
Red: Error
Yellow: Hold/Pause
Green: Normal Operation
KangarooTM ePump
Enteral Feeding Pump Power Button
Below are some probable causes of alarm conditions and their corrections.
For additional operating instructions and information, see the operating manual for the Kangaroo™ePump Enteral Feeding Pump "Feed
Only" Set.
QUICK
REFERENCE
GUIDE
Battery Operation
Unplugging the pump from the AC line will automatically put the pump on battery power.
To recharge the battery, plug the pump into an AC wall outlet. Pump will automatically begin
charging. If A/C power is interrupted, a built-in rechargeable battery will run the pump.
General Instructions
1. Fill or spike feeding container before setting up pump.
2. Turn pump on by pressing Power button in lower right-hand corner.
3. To achieve proper accuracy, the bottom of the feeding set bag must be 18 inches above the
top of the feeding pump.
4. Select Keep Settings or Clear Settings. For day-to-day use with the same feeding regimen,
select Keep Settings.
5. Load the set per diagram.1 Don’t overstretch the tubing.
Priming the Pump
1. Press Prime Pump to access the pump priming options.
2. Press Auto Prime to automatically prime the pump set. The pump will quickly prime
the feed line and stop the formula before reaching the end of the feeding line.
3. Press and hold Hold to Prime Feed to prime the feed line down to the connector at the end
of the pump set.
4. Press Done.
Setting the Feed Rate
1. Select Adjust Feed, then Feed Rate. Use the buttons on the left to program the pump from 1
to 400 in increments of 1 mL. Select Enter when desired rate is set.
2. Select Run. A small drop will scroll down the screen when running.
Repriming the Pump After the Feed Bag Empties
1. A pump set bag that has been emptied will trigger the Feed Error screen. In this condition
the pump set bag can be relled to continue the feeding, but only after the pump set has
been reprimed.
2. Disconnect the feeding line from the patient.
3. Rell the bag.
4. Press Continue to begin the pump running.
5. Press Hold, then press Adjust Settings, then press Prime Pump.
6. Press and hold Hold to Prime Feed to prime the feed line down to the connector at
the end of the pump set.
7. Press Done, then select Run.
To Change Rate or Clear Volume
1. Select Hold.
2. Select Clear Vol Fed to clear the volume.
3. Select Adjust Settings to adjust all settings.
4. Select Run to return to normal operations.
Pump sets should not be reused after 24 hours of initial usage.
QUICK REFERENCE GUIDE
EZ-MODE OPERATION
Kangaroo™ePump Enteral Feeding Pump “Feed Only“ Set
1. For additional operating instructions and information,
see the operating manual for the Kangaroo™ ePump
Enteral Feeding Pump "Feed Only" Set.