EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cleveland
  6. •
  7. Kettle
  8. •
  9. Cleveland 24-EM-K6-24 User manual

Cleveland 24-EM-K6-24 User manual

This manual suits for next models

2

Other Cleveland Kettle manuals

Cleveland 36-GM-K1010-200 User manual

Cleveland

Cleveland 36-GM-K1010-200 User manual

Cleveland HA-MKGL-100-T User manual

Cleveland

Cleveland HA-MKGL-100-T User manual

Cleveland MKDL-100-CC-T User manual

Cleveland

Cleveland MKDL-100-CC-T User manual

Cleveland KGT-12-T User manual

Cleveland

Cleveland KGT-12-T User manual

Cleveland KDL-40-SH User manual

Cleveland

Cleveland KDL-40-SH User manual

Cleveland Steam Jacketed Kettle User manual

Cleveland

Cleveland Steam Jacketed Kettle User manual

Cleveland KDT-1-T User manual

Cleveland

Cleveland KDT-1-T User manual

Cleveland KET-12-TGB User manual

Cleveland

Cleveland KET-12-TGB User manual

Cleveland 42CKDM Series User manual

Cleveland

Cleveland 42CKDM Series User manual

Cleveland KDM Operating instructions

Cleveland

Cleveland KDM Operating instructions

Cleveland SSE-25-L Operating instructions

Cleveland

Cleveland SSE-25-L Operating instructions

Cleveland MKDL-100-T User manual

Cleveland

Cleveland MKDL-100-T User manual

Cleveland MKDL-100-T User manual

Cleveland

Cleveland MKDL-100-T User manual

Cleveland KGL-100 User manual

Cleveland

Cleveland KGL-100 User manual

Cleveland KEL-25-T User manual

Cleveland

Cleveland KEL-25-T User manual

Cleveland KDT-12-T User manual

Cleveland

Cleveland KDT-12-T User manual

Cleveland SD-1050-K 66 User manual

Cleveland

Cleveland SD-1050-K 66 User manual

Cleveland KEL-100 User manual

Cleveland

Cleveland KEL-100 User manual

Cleveland KGL-25 User manual

Cleveland

Cleveland KGL-25 User manual

Cleveland KGL User manual

Cleveland

Cleveland KGL User manual

Cleveland KCL-25-T User manual

Cleveland

Cleveland KCL-25-T User manual

Cleveland IA-MKDL-100-CC User manual

Cleveland

Cleveland IA-MKDL-100-CC User manual

Cleveland KEL-100-T User manual

Cleveland

Cleveland KEL-100-T User manual

Cleveland KEL-40-SH User manual

Cleveland

Cleveland KEL-40-SH User manual

Popular Kettle manuals by other brands

IKEA UPPHETTA manual

IKEA

IKEA UPPHETTA manual

Krups BW500B55 manual

Krups

Krups BW500B55 manual

Clas Ohlson KE7086-BH instruction manual

Clas Ohlson

Clas Ohlson KE7086-BH instruction manual

Brock WK 0902 GR manual

Brock

Brock WK 0902 GR manual

inventum CBW010 instruction manual

inventum

inventum CBW010 instruction manual

Westfalia Retro 81 48 86 instruction manual

Westfalia

Westfalia Retro 81 48 86 instruction manual

Ovente KS88 Series Faqs

Ovente

Ovente KS88 Series Faqs

HUSLOG AK-0832 user manual

HUSLOG

HUSLOG AK-0832 user manual

Saturn ST-EK840 manual

Saturn

Saturn ST-EK840 manual

Wilfa TK-1200B operating instructions

Wilfa

Wilfa TK-1200B operating instructions

HOME ELEMENT HE-KT150 user manual

HOME ELEMENT

HOME ELEMENT HE-KT150 user manual

Breville Crystal Clear BKE290 Instruction booklet

Breville

Breville Crystal Clear BKE290 Instruction booklet

ECG RK 1745 instruction manual

ECG

ECG RK 1745 instruction manual

cecotec THERMOSENSE 600 TOUCH BLACK instruction manual

cecotec

cecotec THERMOSENSE 600 TOUCH BLACK instruction manual

Kalorik JK 39825 operating instructions

Kalorik

Kalorik JK 39825 operating instructions

tomado TM-1971 instruction manual

tomado

tomado TM-1971 instruction manual

Cosori CS108-NK user manual

Cosori

Cosori CS108-NK user manual

Electrolux E7K1-6BP user manual

Electrolux

Electrolux E7K1-6BP user manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Cleveland
™
Project ________________________________
Item __________________________________
Quantity_______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio,U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site:www.ClevelandRange.com
Email: Steam@ClevelandRange.com
MODULAR BASES
MODELS:c24-EM-K6-24
c36-EM-K36-24
c36-EM-K66-24
Cleveland Standard Features
nFactory assembled Kettle/Steam Generator Base
combination with one or two, 6 gallon kettles with 24 KW
Electric Steam Generator
nSolid State steam generator Water Level Controls
nLow Water Safety Cut-off
nPressure Limit Controls with 15 psi Safety Valve
nType 430 Stainless Steel exterior enclosure, and table top
(with Drain Trough which has 1.50" diameter male drain),
#4 exterior finish
nType 304 Stainless kettle(s), #4 exterior finish
nSeparate Start/Rest Illuminated Switch Controls, plus
Pressure Gauge
nMajor components serviceable from the front of the unit
n6gallon kettle(s) are 2/3 Steam Jacket rating, and include
Lift-off Covers
nHot and Cold Water Faucet with Swing Spout
nKettle(s) have 50 psi chrome plated Safety Valve(s) and
Manual Tilting balanced design
nTilt Handles can be mounted on either side
nSteam Generator empties under pressure (blowdown)
automatically upon each Shut-Down. Automatic Water
Refill on Start-Up
n"Clear access" Lift-Off Front Panel
pSecondaryLow Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI.
MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
nStandard voltage is 208volt, 60 Hz, 3 Phase, 3 Wire
nAdjustable Flanged Feet (FF-A)
Options & Accessories
pPower Take-Off Kit (EPTO)
pVoltages other than standard
pType 316 Stainless Steel kettle interior for high acid food
products (316)
pFood Strainers (FS)
pStainless Steel Base Frame (FSS)
pBoiler Descaling Pump Kit (107142)
Shall be CLEVELAND, Modular Cabinet Base with one or two, 6 gallon ket-
tle(s),Model _____ -EM-K _____ -24,with 24KW Electric Steam Generator; type
430 Stainless Steel exterior enclosure, table top and 4 level adjustable feet.
2/3 Steam Jacketed, type 304 Stainless Steel kettle(s) with 50 psi Steam
Jacket Rating; needle type Steam Control Valve on each kettle. Console
mounted Controls, Pressure Gauge and Illuminated "Start/Reset" Control
Switches. Solid State Water Level Steam Generator Controls. Steam
Generator drains under pressure (blowdown) after each Shut-Down with
Automatic Water Refill on Start-Up. 15 psi Safety Valve.
Short Form Specifications
SECT. VII PAGE 21
0707
MODULAR BASE WITH KETTLE(S)
24 KW ELECTRIC STEAM GENERATOR
ONE or TWO 6 GALLON KETTLE(S)
CABINET BASE: 24" (600MM) or 36" (900MM) WIDE
11/2” IPS common drain.
Do not connect other
units to this drain.
The Floor Drain must be
located outside the con-
fines of the equipment.
Do not use PVC pipe for
drain.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., NSF, CGA, CSA, ETL and others.
(NOT TO SCALE)
SECT
.VII P
AGE 22
0707
Litho in U.S.A.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether untreated or pre-treated,
based upon 10 hours of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site water analysis for recommendations
concerning steam generator feed water treatment (if required), in order to remove or
reduce harmful concentrations of minerals. The use of highly mineralized water will mean
that more frequent servicing of the steam generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable for the generator.
CAPACITIES
(in 4 oz. servings)
(Other sizes may be calculated.)
6gallon / 23 liters ..... 160 per kettle
Right - 3”, Left - 3”, Rear - 3”
(12” on control side if adjoin-
ing wall or equipment is over
30” high for service access)