1 of 2 LPN00283X0001A1_A
RUL Series
LED Rural Utility Luminaire
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
TO INSTALL:
LUMINAIRE INSTALLATION
STEP 1:
To open cover, press tabs in on both sides of the cover and carefully let
the cover swing down. See Figure 1.
STEP 2:
Slide fixture on to a 1.66"O.D. or 2.38"O.D. pole tenon or mast arm
through opening on the rear of housing. See Figure 2.
STEP 3:
Adjust leveling of fixture from side to side. To level from front to back,
slide pole to different Adjustment Steps in housing. Each step changes
the angle in 2.5° degree increments.
STEP 4:
Once desired position is achieved, use 9/16" socket wrench to tighten
mounting bolts to 150 in-lbs torque See Figure 2.
STEP 5:
IMPORTANT - DO NOTexceed 300 in-lbs torque on the mount
bolts. Exceeding recommended torque value resulting in excessive
deformation of mounting bracket will cause stripping of mount hardware
which could lead to an unsafe mounting condition. See table on the next
page.
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should
always be followed including the following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1. DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant
l’installation.
2. This luminaire must be installed in accordance with the NEC
or your local electrical code. If you are not familiar with these
codes and requirements, consult a qualied electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n’êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualié.
3. If NEMA®photo control is installed refer to NEMA®Receptacle
section for instructions.
4. If mounting bolts are completely removed in the eld they
should be hand threaded (prior to use of power tools) to
ensure proper engagement of the thread when re-installing.
Failure to pre-start threads may result in cross-threading or
stripping of the bolts during reinstallation.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
1 2
Cover Tabs Mounting
Bracket
Pole
Mounting Bracket
Bolts
Adjustment
Steps
5ME Optic
NOTES:
• For use with max 120VAC.
• Nema®receptacle has orientation stops incorporated to
prevent greater than 360º rotation. Do not force beyond to avoid
damages in the receptacle and/or in the electrical connections
inside the luminaire.
• Prior to installation, store luminaire in a dry location protected
from rain, dust, and outdoor environment. If equipped with a
photocell receptacle, do not store or install luminaire outdoors
without immediately installing a suitable photocell, shorting
cap, or other compatible device. Do NOT leave receptacle open
to environmental elements. Luminaires with a top-mounted
photocell receptacle should not be installed in an up-light
position or at a tilt greater than 45 degrees from the down-light
position.