DAITEM SH401AX User manual


2
3. Position the power pack on the
guide rails.
4. Slide the power pack downwards
until it is locked into place.
Coller sur certif
SH401AX
A12260A0963C
SH401AX
A12260A0963C
5. Guarantee sticker
Remove the pre-cut part of the sticker and
stick it to the guarantee certificate in the
user manual supplied with the control
panel. If you are adding the siren to an
existing system, use the guarantee sticker
provided with this product.
Collersur certif
SH401AX
A12260A0963C
SH401AX
A12260A0963C
To remove the lithium power pack, press on the unlocking key and slide the pack upwards.
Unlocking key
IMPORTA T
• When the siren is powered, it will issue a long beep and automatically switch to installation mode (tamper mechanism
disabled).
• If the siren does not respond as it should: - disconnect the power pack,
- wait for 2 minutes,
- reconnect the lithium power pack,
- check the siren issues a long beep as it should.
2.2 Opening the siren and connecting the power supply
2. Preparing he siren
In addition to the protection provided by the control panel with built-in siren and keypad, the indoor siren deters intruders.
If a fire is detected, the siren is triggered for 5 minutes in fire sounding mode.
Thanks to its built-in transmitter, the siren informs the control panel when it has a battery problem.
If somebody attempts to pull the siren off the wall, it sounds and then triggers all the alerts and deterrents via the control
panel.
1. In roduc ion
2.1 Tooling required
6 mm
PZ 2 IMPORTA T: the fixing screws
and wall plugs are not supplied.
IMPORTA T
• Some functions are only available with versions 2.0.0 or later (press on the control panel keypad to
check the version).
• The operating differences with former ranges are described in the compatibility booklet available in the Daitem installers
section at www.daitem.co.uk.
1. Insert a screwdriver in the bottom-
right hand corner between the base
and the siren and apply pressure to
open
the
siren.
2. Place the siren on a flat surface, remove the base by inclining
it at a 45° angle (A) and pull it downwards (B).
A
45°
B

3
IMPORTA T
• The siren does not need to be placed close to the control panel for recognition programming. In fact, it is advisable to move it
away from the panel (to a distance of at least 2 m).
• The control panel gives the siren a n° during recognition programming.
IMPORTA T: the control panel and
siren issue three short beeps to
indicate a programming error. When
this happens, perform recognition
programming again from the start.
Siren recognition programming sequence
3. Recogni ion programming
))))))))))
10 s max.
Briefly
press the siren
“test” button
Press and hold “Off”
until the control panel
responds
The siren issues an
audible signal to
confirm programming
The control panel
announces
the siren n°
“bip, siren n°”“beeeep”“bip” “bip, off,
control panel”
4. Se ing he parame ers
The siren’s parameters are factory-programmed.
Each parameter can nevertheless be modified using the control panel keypad.
Siren alarm sounding can be delayed by 60 seconds maximum. This gives users enough time to disarm the system before
the alarm siren sounds if, for instance, they have pressed the wrong button. To delay sounding, enter:
Factory setting: 0 s
The control panel and siren must be in installation mode to set the siren’s parameters. If they are not, enter:
then
master code installer code
siren n° from 0 to 60 s
4.1 Delayed alarm sounding upon intrusion
To set the siren’s parameters, first choose the parameters to be modified and then enter:
parameter
n°
siren n° parameter
value
IMPORTA T: all parameter-setting must be done using TwinLoad®software available in the Daitem installers section at
www.daitem.co.uk.
To modify the duration of sounding, enter:
Factory setting: 90 s
siren n° from 20 to 180 s
4.2 Duration of alarm sounding
Recognition programming allows the siren to be recognised by the control panel.
It must be done with the control panel and siren in installation mode. If they are not in installation mode, enter:
then
master code installer code

4
To change the transfer of indications, enter:
Factory setting: 1
siren n° 0: disabled
1: sounding
4.4 Transfer of arm and disarm commands
This function is factory-set to be enabled. It can be deactivated if required. To do this, enter:
Factory setting: 1
siren n° 0: disabled
1: enabled
4.5 Indication of audible signals and door bell
This function is used to validate the radio link test in installation mode on 1 or 2 radio bands.To switch to 2 bands, enter:
Factory setting: 0
siren n° 0: validation on 1 of the 2 bands
1: validation on 2 bands
4.6 Validation of radio link in installation mode
The alarm is factory-set to be triggered as soon as an intrusion is detected. This function can be deactivated or activated for
intrusion confirmed indications only. To do this, enter:
Factory setting: 1
siren n° 0: disabled
1: single or confirmed intrusion
2: confirmed intrusion only
4.7 Triggering upon intrusion
The siren is factory-set to sound loudly for 15 s in case of intrusion. It can be deactivated or changed to quiet sounding.
To do this, enter:
Factory setting: 2
siren n° 0: disabled
1: quiet sounding (4 beeps)
2: loud sounding (15 s)
4.9 Alarm indication in armed presence mode
When this function is enabled, the siren issues a series of 4 beeps to indicate that the system is armed. The function can be
deactivated.
Factory setting: 1
siren n° 0: disabled
1: quiet sounding (“bip, bip, bip, bip”)
4.8 Protection system armed indication
For greater user-friendliness, the sound level can be increased or decreased. To do this, enter:
Factory setting: 4 = average
siren n° from 1 to 8
4.3 Sound level of arm and disarm command indications
When this function is enabled, loud sounding can be triggered (except when parameter 26 is set at 0).
Factory setting: 0
siren n° 0: disabled
1: loud sounding triggered if the system is totally armed
2: loud sounding triggered 24/24
4.10 Triggering following a communication network interruption

5
If the radio links are deliberately tampered with, the siren is triggered.
To activate or deactivate the radio tamper system, enter:
Factory setting: 1
siren n° 0: disabled
1: enabled
4.10 Radio tamper
To allocate the siren to one or several alarm system groups,
enter:
Factory setting: all groups
Example: to allocate siren n° 1 to Group 2 and Group 3,
enter:
...
siren n° groups from 1 to 8 depending
on the type of control panel
4.11 Allocation of siren to alarm group
4.12 Checking
To check parameter-setting, enter: Example: to check on siren n° 1, lparameter 4: duration of
sounding, enter:
siren n° parameter
n°
“4, bip, 9, 0”
4.13 Deletion of parameters
• To delete a parameter, enter
siren n° parameter
n°
• To delete all parameters, enter:
siren n°
The siren should preferably be placed:
• at a height,
• far away from possible sources of electrical interference
(electricity meter, telephone box, etc.).
ever fix the siren to a metal wall.
5. Ins alling he siren
5.1 Choosing the best place to install the siren
IMPORTA T: make sure there is a distance of at least
2 metres between each product, except between two
detectors.
5.2 Testing the radio range
Before fixing the siren in place, test its radio range in the chosen location by putting it there.
If the test is satisfactory, fix the siren in place. Otherwise, move it to a different location.
1. Press the test button. 2. The control panel issues the message:
“bip, siren X”

1. Loosen the siren locking screw.
2. Open the siren.
3. Check triggering:
- of the siren,
- of the control panel,
- of the telephone dialler.
4. Issue an Off order.
6. Performing a real es
Testing triggering when there is an attempt to remove the siren
IMPORTA T: the sounding level of the siren can cause
hearing disorders. The necessary precautions must therefore
be taken before testing siren triggering.
6
5.3 Fixing the siren in place
1. Remove the tamper mechanism washer
located on the back of the siren.
2. • For the siren to be installed there must be a space of 6 cm to the
left of the base, 4 cm above and 18 cm below. This clearance
allows for the siren to be easily opened or locked.
2. • Fix the siren at 3 points.
4. Close the siren and lock it using the screw located inside the
product.
Detachable
tamper
mechanism
washer
(A) 45°
Pozidriv 2
Pozidriv 2
3. Open the siren at an angle of 45° (A) in
relation to the base and insert the pivots on
the base into the hinges.
Bottom view of siren
Siren locking Siren opening
Tamper hole with washer (A)
Detachable tamper
mechanism washer
Insert adjustable fixing washers here
6 cm
18 cm
mur
4 cm
45°
A

7
The control panel supervises and identifies the siren.
It monitors the state of the:
• power supply,
• radio link,
• tamper contact.
If a fault is memorised the control panel issues a voice message to indicate the fault following a system command
(see § Fault indications in the control panel installation manual).
7. Main enance
7.1 Fault indications
To change the battery:
1. send a disarm command,
2. switch the control panel to installation mode:
then
3. remove the siren from the wall,
4. remove the faulty lithium power pack,
5. wait for 2 minutes before connecting the new lithium pack,
6. close the siren and put it back on its base,
7. switch the control panel to user mode:
8. test triggering.
7.2 Changing the battery
master code
installer code
installer code
• The lithium battery pack must be replaced by the same type of pack with the same technical characteristics,
i.e. 2 x (3.6 V – 13 Ah).
• We advise you to use the DAITEM BatLi22 pack available in the catalogue in order to guarantee individual safety
and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
Li
8. Summary of parame ers
Parameter description Parameter-setting sequence Factory Possible values Page
parameter
Delayed sounding ** 4 * siren n° * 3 * ?? ** 0: immediate from 0 to 60 s 3
upon intrusion 0: immediate
Sounding duration ** 4 * siren n° * 4 * ??? ** 90 s from 20 s to 180 s 3
Sound level of disarm/arm ** 4 * siren n° * 11 * ? ** 4: average from 1 to 8 4
indications
Transfer of disarm/arm ** 4 * siren n° * 12 * ? ** 1: sound 0: disabled 4
indications 1: sounding
Indication of audible signals ** 4 * siren n° * 13 * ? ** 1: enabled 0: disabled 4
and door bell 1: enabled
Validation of radio link ** 4 * siren n° * 15 * ? ** 0: on one 0: validation on 1 of 2 bands 4
in installation mode of 2 bands 1: validation on 2 bands
Triggering upon intrusion ** 4 * siren n° * 20 * ? ** 1: single 0: disabled 4
or confirmed 1: single or confirmed intrusion
intrusion 2: confirmed intrusion only
Protection system armed ** 4 * siren n° * 21 * ? ** 1: audible 0: disabled 4
indication 1: sounding
Alarm indication in armed ** 4 * siren n° * 22 * ? ** 2: loud sounding 0: disabled 4
presence mode (15 s) 1: quiet sounding (4 beeps)
2: loud sounding (15 s)
Triggering upon ** 4 * siren n° * 26 * ? ** 0: disabled 0: disabled 4
communication network 1: loud sounding triggered if the system
interruption is totally armed
2: loud sounding triggered 24/24
Radio tamper ** 4 * siren n° * 27 * ? ** 1: enabled 0: disabled 5
1: enabled
Allocation of a siren to one ** 4 * siren n° * 37 * ? ** all groups Selection of group(s): from 1 to 8 5
or several intrusion groups depending on type of control panel
Deletion of all parameters ** 4 * siren n° * 197 *** - - 5
Deletion of one parameter ** 4 * siren n° * para eter n° ** 0 ** - - 5

9. Technical da a
Technical specifications SH401AX siren
Acoustic level 93 dB at 1 m
Sounding duration 20 s to 180 s
Internal sounding 3600 Hz to 4200 Hz with 6 Hz modulation
Fire sounding 700/900 Hz, sounding duration: 5 min.
Transfer of Arm/Disarm indications audible
Environment indoor
Power supply TwinPower®via lithium power pack (2 x 3.6 V)
Battery life 5 years in normal conditions of use
Average current consumed 222 µA
Average humidity rate 5% to 75% without condensation at 25°C
Radio links TwinBand®400/800 MHz
Supervision radio, lithium pack, tamper
Operating temperature -10°C to + 50°C
Tamper protection against • opening
• removal
Degrees of mechanical protection IP 31/I 04
W x H x D 192 x 192 x 59.5 mm
Weight 900 g (with battery)
Security grade grade 2 according to standard EN 50131-4
Environmental class class II according to standard EN 50130-5
DECLARATIO OF CO FORMITY
Manufacturer: Hager Security SAS
Address: F-38926 Crolles Cedex - France
Product type: Siren
Trade mark: Daitem
We declare under our sole responsibility that the product to which this declaration
relates is compliant with the essential requirements of the following directives:
• R&TTE directive: 99/5/EEC
• Low voltage directive: 2006/95/EC
• ROHS directive: 2002/95/EC
in compliance with the following harmonised European standards:
This product can be used in all EU, EEA Countries and Switzerland.
Crolles, 31.08.2012 Signature:
Patrick Bernard
Research & Development Manager
Product references SH401AX
E 300 220-2 V3.2.1 X
E 50130-4 (95) + A1 (98) + A2 (2002) X
E 55022 & 55024 (2002) X
E 60950 (2006) X
E 301 489-1 V1.8.1 X
Non-binding document, subject to modification without notice.
12
GB
805146/A - 12.2012
To obtain advice when installing your syste or before returning equip ent, please contact the Daite
technical support tea (see telephone nu ber at the back of the alar syste installation anual)
or check the web site at:
www.daitem.co.uk
A tea of qualified technicians will advise you what to do.
Table of contents
Other DAITEM Security System manuals

DAITEM
DAITEM SH402AX User manual

DAITEM
DAITEM 473-29X User manual

DAITEM
DAITEM SH426AX User manual

DAITEM
DAITEM ALARM SYSTEM AND DIALLER User manual

DAITEM
DAITEM SH146AX User manual

DAITEM
DAITEM MD500 Operation and maintenance manual

DAITEM
DAITEM SH640AX User manual

DAITEM
DAITEM SH402AX User manual

DAITEM
DAITEM DP8406 User manual

DAITEM
DAITEM SH601AU User manual