manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Dräger
  6. •
  7. Respiratory Product
  8. •
  9. Dräger PAS Colt Series User manual

Dräger PAS Colt Series User manual

Other Dräger Respiratory Product manuals

Dräger X-plore 9500 User manual

Dräger

Dräger X-plore 9500 User manual

Dräger FPS-COM 7000 User manual

Dräger

Dräger FPS-COM 7000 User manual

Dräger PAS AirPack 1 User manual

Dräger

Dräger PAS AirPack 1 User manual

Dräger X-plore 8000 User manual

Dräger

Dräger X-plore 8000 User manual

Dräger FPS 7000 User manual

Dräger

Dräger FPS 7000 User manual

Dräger Panorama Nova RP User manual

Dräger

Dräger Panorama Nova RP User manual

Dräger PSS BG 4 User manual

Dräger

Dräger PSS BG 4 User manual

Dräger PAS Colt Series User manual

Dräger

Dräger PAS Colt Series User manual

Dräger X-plore 8000 User manual

Dräger

Dräger X-plore 8000 User manual

Dräger X-plore 8000 User manual

Dräger

Dräger X-plore 8000 User manual

Dräger Oxy 3000 MK II User manual

Dräger

Dräger Oxy 3000 MK II User manual

Dräger Panorama Nova P - sideport - RA User manual

Dräger

Dräger Panorama Nova P - sideport - RA User manual

Dräger Oxy K 30 HWT User manual

Dräger

Dräger Oxy K 30 HWT User manual

Dräger X-plore 9500 User manual

Dräger

Dräger X-plore 9500 User manual

Dräger PSS 5000 Series User manual

Dräger

Dräger PSS 5000 Series User manual

Dräger PAS Micro Series User manual

Dräger

Dräger PAS Micro Series User manual

Dräger X-plore 6000 User manual

Dräger

Dräger X-plore 6000 User manual

Dräger PSS AirBoss Connect User manual

Dräger

Dräger PSS AirBoss Connect User manual

Dräger FPS 7000 User manual

Dräger

Dräger FPS 7000 User manual

Dräger Panorama Nova S - ESA User manual

Dräger

Dräger Panorama Nova S - ESA User manual

Dräger Panorama Nova S User manual

Dräger

Dräger Panorama Nova S User manual

Dräger PSS User manual

Dräger

Dräger PSS User manual

Dräger SPC 4400 User manual

Dräger

Dräger SPC 4400 User manual

Dräger PSS Series User manual

Dräger

Dräger PSS Series User manual

Popular Respiratory Product manuals by other brands

ResMed MIRAGE SWIFT II 60891/1 user guide

ResMed

ResMed MIRAGE SWIFT II 60891/1 user guide

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

3M 8000 Series quick start guide

3M

3M 8000 Series quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

BLS 8000 Instructions for the use

BLS

BLS 8000 Instructions for the use

SATA Vision 2000 operating instructions

SATA

SATA Vision 2000 operating instructions

DeVilbiss UltraNeb user manual

DeVilbiss

DeVilbiss UltraNeb user manual

KYARA OBLO' LTK110 instruction manual

KYARA

KYARA OBLO' LTK110 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

3352429 (A3-D-P)
PAS Colt Series
Combination escape SCBA/airline SAR respiratory protection equipment
Instructions for Use
i
1
2
1
3629
2
3628/3627
6
3626
3
3630
7
3632
8
3633
9
3634
4
3631
5
3625
1 For your safety
1.1 General safety statements
● Beforeusingthisproduct,carefullyreadtheInstructionsforUse.
● StrictlyfollowtheInstructionsforUse.Theusermustfullyunderstandandstrictly
observe the instructions. Use the product only for the purposes specied in the
IntendedUsesectionofthisdocument.
● Do not dispose of the Instructions for Use. Ensure that they are retained and
appropriatelyusedbytheproductuser.
● Onlyfullytrainedandcompetentusersarepermittedtousethisproduct.
● Complywithalllocalandnationalrulesandregulationsassociatedwiththisproduct.
● Onlytrainedandcompetentpersonnelarepermittedtoinspect,repairandservice
the product. Dräger recommends a Dräger service contract for all maintenance
activitiesandthatallrepairsarecarriedoutbyDräger.
● Properlytrainedservicepersonnelmustinspectandservicethisproductasdetailed
inthemaintenancesectionofthisdocument.
● UseonlygenuineDrägersparepartsandaccessories,ortheproperfunctioningof
theproductmaybeimpaired.
● Donotuseafaultyorincompleteproduct,anddonotmodifytheproduct.
● NotifyDrägerintheeventofanycomponentfaultorfailure.
● Before occupational use of this respirator a written respiratory protection
programmustbeimplementedmeetingallthelocalgovernmentrequirements.
IntheUnitedStatesemployersmustcomplywithOSHA29CFR1910.134which
includesmedicalevaluation,training,andttesting.
1.2 Denitionsofalerticons
Alerticonsareusedinthisdocumenttoprovideandhighlighttextthatrequiresagreater
awarenessbytheuser.Adenitionofthemeaningofeachiconisasfollows:
!
WARNING
 Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultin
deathorseriousinjury.
!
CAUTION
 Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultin
physicalinjuryordamagetotheproductorenvironment.Itmayalsobeusedto
alertagainstunsafepractices.
i
i
NOTICE
 Indicatesadditionalinformationonhowtousetheproduct.
2 Description
2.1 Product overview
Thisvariant ofthe Dräger PASColt Series provides respiratory protection for working
in a contaminated environment using an airline (supplied airline respirator – SAR),
or escaping from a contaminated environment using the air cylinder (self-contained
breathingapparatus–SCBA).
During airline use, the PAS Colt is connected to a breathing-quality independent air
supply and the cylinder valve is closed. If the independent air supply falls below the
requiredpressure,theweareropensthecylindervalve,disconnectstheindependentair
supplyandthenescapestoasafeareabreathingairfromthecylinder.Thetimeavailable
fortheescapeisdependentonthecapacity(volume)ofthecylinderandthebreathing
rateofthewearer.
Thefeaturesoftheequipmentare:
● Thecarryingsystemisabandoliershoulderharnessandwaistbelt.
● Thelungdemandregulator(LDR)hasaresetbutton(Fig1,Item1)thatswitches
offtheairowthroughtheregulator,andapurgebutton(Fig1,Item2)thatcanbe
usedtodeliveranadditionalairowintothefacemaskwhenrequiredbythewearer
duringairlineuse.Theholder(Fig2,Item1)providesastowagepointtoprotectthe
regulatorcouplingandO-ringagainstdamagewhenitisnotttedinthefacemask.
● Therst-stageregulator(Fig2,Item2)hasananti-vibrationstrapttedthatisused
topreventlooseningoftheconnectorhandwheel.
● Theairlineconnector(Fig2,Item3)isamalecouplingthatisusedtoconnectan
independentairsupplyforsuppliedairlinerespirator(SAR)use.
● Alow-pressurewhistleisttedonsomevariantsofthisproduct(seeSection2.1.1).
● Thehip-mountedcylinderholsterhasadropdownfacilitythatcanassistwearer
movementbymakingthecylinderandholstermoremanoeuvrable(inaconned
spaceforexample).
● Theremainingpressureintheaircylinderisshownonacontentsindicatoronthe
cylinder.
● Athighstrapisavailableasanaccessory.
2.1.1 Low-pressure whistle (optional)
IfthePASColtisttedwithalow-pressurewhistle,itoperatesasfollows:
● Duringairlineuse,thewhistlesoundstowarnthewearerthattheindependentair
supplyhasfallenbelowtherequiredpressure.
i
i
NOTICE
 During an escape (when the wearer is breathing from the air cylinder), the
whistlesoundswhenthecylinderpressureisverylow.Thisisnotanend-of-
service-timeindicator(EOSTI).
Seethetechnicaldata(Section9)forthewhistleoperatingpressures.
2.2 Intended use
Whenthisproductisusedwithanapprovedfacemask,aircylinderandindependent
air supply, it provides the wearer with respiratory protection for working in, or
escapingfrom,contaminatedoroxygen-decientconditions.Itisintendedforusein
applicationswhereahighlevelofrespiratoryprotectionisrequired,includingIDLH
(immediatelydangeroustolifeandhealth)atmospheres.
The air cylinder, face mask and other accessories used with this product must be
certiedDrägercomponents,assembledinanapprovedconguration;otherwisethe
operationofthedevicemaybeimpaired.Itisessentialthatushingandnon-ushing
facemasksandlungdemandregulatorsshouldnotbemixed(i.e.onlyaushing-
typefacemaskshouldbeusedwithaushing-typelungdemandregulator).Contact
Drägerforfurtherinformation.
2.3 Limitations on use
ThisproductisnotapprovedforuseinCBRNapplications.
2.4 Approvals
The PAS Colt Series of combination escape/airline respiratory protection equipment
conformstotherequirementsofNIOSH.Thisproductisapprovedforuseasasupplied
airlinerespirator(SAR)andasaself-containedescaperespirator,andmustonlybeused
inconjunctionwithcompressed-aircylindersapprovedbyNIOSH.
3 Use
!
WARNING
 Thetimerequiredtoallowthewearertoescapetoasafeareamustbewithin
thecapacity(volume)ofthecylinderselected,takingintoaccountthebreathing
rateofthewearer.Whenselectingthetypeanddurationofescapeequipment
itisessentialtoconsiderthepotentialhazardsandprobableescaperoutes.
 Thecylinderandairlineairqualityshallmeettherequirementsforbreathingair
accordingtoCGAG-7.1GradeDorhigherquality.
Beforeusingairlineequipment,ensurethattheindependentairsupplymeets
theairqualityrequirementsandcomplieswithpressure,owandhoselength
requirementsinthetechnicaldata(seeSection9),andhasbeenissuedwitha
permitforuseifnecessary.
 IfusingaPASColtwithoutanintegrallow-pressurewhistle,Drägerrecommend
thatalow-pressurewarningdeviceisttedtotheindependentairsupply.
D
3000 PSI
EMPTY FUL
14
1234
USE
NO
OIL
D
3000 PSI
EMPTY FUL
14
1234
USE
NO
OIL
D
3000PSI
EMPTY FUL
14
1234
USE
NO
OIL
1
2
3
3
2
1
i
i
NOTICE
 Afterstorage attemperatures below32 °F(0 °C)leakage may be observed
whenthecylindervalveisinitiallyopenedduetoiceformation.
● Ifleakageisobservedfromthelungdemandregulator:Pressthepurge
button(Fig1,Item2)toallowarushofairtopassthroughthelungdemand
regulatorandthenquicklypresstheresetbutton(Fig1,Item1)toswitch
offthepositivepressure.Resumenormaloperation.
● Intheeventthatleakagestilloccurs,removethebreathingapparatusfrom
serviceandreportthefaulttotrainedservicepersonnelorcontactDräger.
3.1 Preparation for use
3.1.1 Visual inspection
Carry out a visual inspection, checking the full breathing apparatus including all
componentpartsandaccessories.Checkthattheequipmentiscleanandundamaged,
paying particular attention to pneumatic components, hoses and connectors. Typical
signsofdamagethatmayaffecttheoperationofthebreathingapparatusincludeimpact,
abrasion,cutting,corrosionanddiscoloration.Reportdamagetoservicepersonneland
donotusetheapparatusuntilfaultsarerectied.
3.1.2 Fitting the cylinder
1. Ensurethatthe cylinder isfully charged, withthe pointer ofthecylinder pressure
indicatorinsidethegreenarea.
2. Check that the threads of the valve port and the regulator handwheel are
undamaged,andtheO-ringisinpositionandundamaged.
3. Fullyinsertthecylinderintothecarryingholster.
!
CAUTION
 Topreventdamage,ensurethatthecylinderremainsclearofthehandwheelof
therst-stageregulatorwhileinsertingthecylinder.
4. Alignthecylinderwiththeregulatorandtightenthehandwheelhandtight(Fig3).
5. Pulltheanti-vibrationstrapoverthetopofthecylindervalve(Fig4).
3.1.3 Functional testing
!
WARNING
 If breathing apparatus fails to meet any of the standards or parameters
describedinthefunctionaltests,orifanimmediateleakisevident,thereisa
systemfault.ReportthefaulttotrainedservicepersonnelorcontactDräger.Do
notusethebreathingapparatusuntilthefaultconditionisrectied.
Leak test
1. Ensurethatthepointerofthecylinderpressureindicatorisinsidethegreenarea.
2. Presstheresetbutton(Fig1Item1)ofthelungdemandregulatortoswitchoffthe
positivepressure.
3. Openthecylindervalveslowly,butfully,topressurizethesystemandthenclosethe
valve.Thereshouldbenoaudibleleak.Ifthereisanyleak,investigateandrepair
theleakbeforeuse.Ifnecessary,useasoapysolutiontolocatetheleak.
4. Pressthepurgebutton(Fig1,Item2)toventthesystem.
Airlineowtest(onlyrequiredforairlineuse)
1. Presstheresetbutton(Fig1,Item1)ofthelungdemandregulator,andthencheck
thatthecylindervalveisclosed.
2. Connect the independent air supply to the male coupling (Fig 2, Item 3). If the
independentairsupplyhasashut-offvalve,openthevalve.
!
WARNING
 Donotdirecttheairowontotheface,eyesorskin.
3. Pressthepurgebutton(Fig1,Item2)for3to5seconds.Anunobstructedairow
shouldowfromtheoutletofthelungdemandregulator.
4. Isolateanddisconnecttheindependentairsupply.
5. Pressthepurgebutton(Fig1,Item2)toventthesystemandthenpressthereset
button(Fig1,Item1)toswitchoffthepositivepressure.
3.1.4 Putting on the PAS Colt (ready position)
 ReferalsotoFig2whichshowsthePASColtworninthereadyposition.
1. Ensurethatthepointerofthecylinderpressureindicatorisinsidethegreenarea.
2. Openthewaistbeltbuckleandfullyextendthewaistandshoulderstrap.
3. Placetheleftarmthroughtheshoulderharness,takingtheharnessoverthehead
andontotherightshoulder,positioningthestrapdiagonallyacrossthebodywiththe
cylinderpositionedagainstthelefthip.
4. Loopthewaistbeltaroundthewaistandfastenthebuckle–donottighten.
5. Gripthecylindervalvewiththelefthandandliftuntilthewaistbeltisinlinewiththe
waist.Thentightenthewaistbeltstrapuntiltheequipmentissecureandcomfortable
onthewaist.Pulldowntoadjusttheshoulderstrap.
6. InspectthefacemaskasdenedintherelevantInstructionsforUse.
7. CheckthatthefacemaskportandtheregulatorO-ringarecleanandundamaged.
8. Removethelungdemandregulatorfromtheholderandpressitintotheportofthe
facemaskuntilitlatchesinposition.Checktheattachmentbygentlyattemptingto
pullthecouplingapart.
9. Puttheneckstrapofthefacemaskoverthehead,andtheninserttheneckstrap
studintotheholeinthecentrestrapoftheheadharness.
3.2 During use
ThisvariantofthePASColtSeriescanbeusedforcombination(escape/airline)useor
purelyforescapeuse.Forcombinationusethefacemaskiswornduringthetask;and
forescapeusethePASColtisworninthereadypositionuntilanescapeisnecessary.
Dependingontheintendeduse,refertotherelevantproceduresfromthefollowing:
● Forcombination(escape/airline)use,seeSection3.2.1
● Forescapeuseonly,seeSection3.2.2
3.2.1 Combination (escape/airline) use
Putting on the face mask
1. Presstheresetbutton(Fig1,Item1)ofthelungdemandregulatortoswitchoffthe
positivepressure.
2. Connect the independent air supply to the male coupling (Fig 2, Item 3). If the
independentairsupplyhasashut-offvalve,openthevalve.
!
WARNING
 Correcttofthefacemaskcanonly be achievedifthecompletefacemask
sealmakescontactwithskin.Headhair,facialhair(includingbeardstubbleand
sideburns),earrings,otherfacialpiercingsandnormalspectacleswillinterfere
withthefacemasksealandarenotpermittedinthesealingarea.Additionally,
headhairthatcouldaffectthefacemaskt(buns,pony-tails,hairpieces,etc.)
isnotpermitted.
i
i
NOTICE
 ReferalsotothefacemaskInstructionsforUse.
3. Detachtheneckstrapstudfromthecenterstrapoftheheadharness.
4. Spreadtheheadharness(Fig5).Placethechinintothechincupofthefacemask
andpulltheharnessovertheheadlocatingtheharnesscenterplateonbackofthe
head.
5. ReferringtoFig6,tightenbothlower(1)andthenupperstraps(2)evenlytowards
back of the head. If necessary, tighten the center strap (3). The wearer’s rst
inhalationafterachievingafacesealwillautomaticallyswitchontheairsupplyinto
thefacemask.
6. Check that the head has a full range of movement without pulling against the
regulator hose. If any resistance to movement is felt, readjust the hose routing
andthenrecheck.Ifresistanceisstillfelt,do notusethebreathingapparatusand
contactDräger.
Function check
1. Isolate the independent air supply (close the valve or disconnect) and breathe
normallytoemptythesystemofair.Whenempty,thefacemaskshouldholdonto
thefacetoindicateapositiveseal.
2. Immediatelyreapplytheindependentairsupplyandbreathenormally.
3. Inhaleandholdyourbreath–thereshouldbenoaudibleleak.Ifaleakisdetected,
readjusttheheadharnessandretest.
4. Recommencebreathing–exhaledairshouldoweasilyoutoftheexhalationvalve.
5. Momentarilypressthepurgebutton(Fig1,Item2)tocheckforadditionalairow.
When the function check has been satisfactorily completed, breathe normally and
proceedtotheworkingarea.
Escape procedure (independent air supply failure)
!
WARNING
 Duringsuppliedairlinerespirator(SAR)use,thePASColtcylindervalvemust
remainclosed.Theescapedurationstartsfromthetimeofopeningthecylinder
valveanddisconnectingtheairlinesupply.
 Drägerstronglyadvisethatthepurgebutton(Fig1,Item2)isnotusedduring
anescape.Usingthepurgebuttonwoulduseairfromthecylinderandreduce
thetimeavailableforescape.
i
i
NOTICE
 IfthePASColtisttedwithalow-pressurewhistle,duringairlineusethewhistle
soundstoindicatethattheindependentairsupplyhasfallenbelowtherequired
pressure.Ifthewhistlesoundsandthenstopsbeforetheescapeprocedureis
started,theairsupplypressurecouldhavebeenrestored.The wearer must
conrm that the correct pressure (87 to 125  psi) is available, or escape as
describedbelow.
Iftheindependentairsupplyfails,breathenormallyandimmediatelyproceedasfollows:
1. Openthecylindervalve(counterclockwise)slowly,butfully,andcontinuetobreathe
normally.
2. DisconnecttheindependentairsupplyfromthePASColt.
3. Immediatelyleavethehazardousareabytheshortestandsafestescaperoute.
Thewearermustbeinasafeareabeforetheaircylinderisempty.Wheninasafearea,
remove the lung demand regulator from the face mask if necessary and continue to
breathenormally.
i
i
NOTICE
 IfthePASColtisttedwithalow-pressurewhistle,duringanescapethewhistle
wouldsoundwhenthecylinderpressurewasintherange72.5to58psi.This
isnotanend-of-service-time-indicator(EOSTI).
3.2.2 Escape use only (putting on the face mask and escaping)
!
WARNING
 Correcttofthefacemaskcanonly be achievedifthecompletefacemask
sealmakescontactwithskin.Headhair,facialhair(includingbeardstubbleand
sideburns),earrings,otherfacialpiercingsandnormalspectacleswillinterfere
withthefacemasksealandarenotpermittedinthesealingarea.Additionally,
headhairthatcouldaffectthefacemaskt(buns,pony-tails,hairpieces,etc.)
isnotpermitted.
i
i
NOTICE
 ReferalsotothefacemaskInstructionsforUse.
1. Presstheresetbutton(Fig1,Item1)ofthelungdemandregulatortoswitchoffthe
positivepressure.
2. Open the cylinder valve (counterclockwise) slowly, but fully, to pressurize the
system.
3. Detachtheneckstrapstudfromthecenterstrapoftheheadharness.
4. Spreadtheheadharness(Fig5).Placethechinintothechincupofthefacemask
andpulltheharnessovertheheadlocatingtheharnesscenterplateonbackofthe
head.
5. ReferringtoFig6,tightenbothlower(1)andthenupperstraps(2)evenlytowards
back of the head. If necessary, tighten the center strap (3). The wearer’s rst
inhalationafterachievingafacesealwillautomaticallyswitchontheairsupplyinto
thefacemask.
3352429 (A3-D-P)
PAS Colt Series
Combination escape SCBA/airline SAR respiratory protection equipment
Instructions for Use
i
3352429
©DrägerSafetyUKLimited
Edition11–November2015
Subjecttoalteration
!
WARNING
 Thedurationofthecylinderairbeginsfromthetimeoftherst-breathactivationofthelungdemandregulator.
 Drägerstronglyadvisethatthepurgebutton(Fig1,Item2)isnotusedduringanescape.Usingthepurgebuttonwoulduseairfromthecylinderandreducethetimeavailable
forescape.
6. Immediatelyleavethehazardousareabytheshortestandsafestescaperoute.
Thewearermustbeinasafeareabeforetheaircylinderisempty.Wheninasafearea,removethelungdemandregulatorfromthefacemaskifnecessaryandcontinuetobreathe
normally.
3.2.3 Dropdown cylinder holster
• Toreleasethedropdowncylinderholster:
 a. Holdthecylindervalvewiththelefthandand,withtherighthand,pressandholdtheredbuttontoopenthelockingmechanism(Fig7).
 b. Liftthecylinderandholsterclearofthelockingmechanismandthenreleasetheredbutton(Fig8).
 c. Lowerthecylinderuntilitissupportedbytheharnessstraps(Fig9).Theholsterisheldbytwoharnessstraps,onexedandoneadjustable.
 d. Holdthecylindervalvetomovethecylinderandholsterasrequired.
• Toreconnectthedropdowncylinderholster,alignandpresstherollerontheholsterintothelockingmechanism.
3.3 After use
!
WARNING
 Donotremovetheequipmentuntilinsafearea,clearofhazard.
!
CAUTION
 Donotdroporthrowdownequipmentasdamagecouldoccur.
1. Loosenthefacemaskstraps.Asthesealbetweenthefacemaskandthefaceisbroken,presstheresetbutton(Fig1,Item1)toswitchoffthepositivepressure.Removetheface
maskandfullyextendallofthestrapsoftheheadharness.
 ○ Afterairlineuse–isolateanddisconnecttheindependentairsupplyfromthePASColt.Retthecapontotheairlineconnector.
 ○ Afteranescape–closethecylindervalve.
2. Pressthepurgebutton(Fig1,Item2)tofullyventthesystem.
3. Removethelungdemandregulatorfromthefacemaskandstowitintheholder(Fig2,Item1).
4. Unbucklethewaistbelt,lifttheshoulderstrapbuckletoloosentheharnessandthenremovetheequipment.
5. Carryouttheafterusemaintenancetasksinthemaintenancetable(seeSection5.1).
4 Troubleshooting
The troubleshooting guide shows fault diagnosis and repair information applicable to breathing apparatus users. Further troubleshooting and repair information is available in
InstructionsforUsesuppliedwithassociatedequipment(e.g.facemask).
ContactservicepersonnelorDrägerwhentheremedyinformationindicatesaservicetask,orifthesymptomremainsafterallremedyactionshavebeenattempted.
Symptom Fault Remedy
High-pressureairleakorfailedleaktest Looseordirtyconnector Disconnect,cleanandreconnectcouplingsandretest
Faultyhoseorcomponent Substituteuserreplaceableaccessoriesandretest
Airleakfromlungdemandregulator Iceparticlesonsealingelements Pressthepurgebutton(Fig1,Item2)toallowarushofairtopass
throughthelungdemandregulatorandthenquicklypressthereset
button(Fig1,Item1)toswitchoffthepositivepressure.
Airleakfrommedium-pressurehoseconnection
attherst-stageregulator(safetyreliefvalve)
FaultyO-ring,retainer,springorrst-stage
regulator
Servicetask
Highorlowmediumpressure First-stageregulatorfault Servicetask
Poorsoundingwhistle(iftted) Whistledirty Cleanwhistleuteandretest
Whistlenotfunctioningcorrectly(iftted) Activationmechanismfault Servicetask
5 Maintenance
5.1 Maintenance table
Serviceandtestthebreathingapparatus,includingout-of-useapparatus,inaccordancewiththemaintenancetable.Recordallservicedetailsandtesting.ReferalsototheInstructions
forUseforthelungdemandregulator,facemaskandotherassociatedequipment.
Additionalinspectionandtestingmayberequiredinthecountryofusetoensurecompliancewithnationalregulations.
Daily check–IfthePASColtisheldinaready-for-usecondition,checkdailythatthepointerofthecylinderpressureindicatorisinsidethegreenarea.Chargethecylinderifitisin
theredarea(seeSection5.2.2).
Component/
System
Task After use Every month Every year Every 10 years
Complete
apparatus
Cleananddisinfect(seeSection5.3) m
Visualinspection(seeSection3.1.1) m m
Functionaltesting(seeSection3.1.3) m m
Flowandstatictests(seeNote1) m
Lungdemand
regulator
Cleananddisinfect(seeNote2andSection5.3) m
First-stage
regulator
Medium-pressurecheck(seeNote1) m
Inspectthesinteredlter(seeNote1andNote3) m
Inspectthehigh-pressureconnectorO-ring(seeNote1andNote4) m
Overhaul.ContactDrägerfortheRepairExchange(REX)service(seeNote5) m
Cylinder Chargecylindertocorrectworkingpressure(seeSection5.2.2) m
Checkchargedpressure(storedcylindersonly) m
Checktestdateofcylinder(carboncompositecylindersover15yearsoldmustberetired) m
Recertication Accordingtonationalregulationsinthecountryofuse
Cylindervalve Overhaul Atthetimeofcylinderrecertication
Notes
m Drägerrecommendations
1 ThesemaintenancetasksmayonlybecarriedoutbyDrägerortrainedservicepersonnel.DetailsofthetestsarecontainedintheTechnicalManualwhichisissuedtoservice
personnelthathaveattendedarelevantDrägermaintenancecourse.
2 Lightly lubricate the O-ring of the lung demand regulator as required (recommended lubricant is Dow Corning 111 Valve Lubricant and Sealant). Products other than the
recommendedlubricantarenottestedandmaydamagetheequipment.
3 Replacethesinteredlterifadropinrst-stageregulatorperformanceisobservedduringaowcheckorifitisvisiblydamaged.
4 Replacethehigh-pressureconnectorO-ringifitisfoundtoleakduringfunctionaltestingoriftheO-ringisvisiblydamaged.
5 Wherethebreathingapparatusissubjectedtoahighlevelofuse(intrainingestablishmentsetc.),reducetheoverhaulperiodfortherst-stageregulator.Inthesecircumstances,
Drägerrecommendthattheoverhaulfrequencyshouldbelessthan5,000applicationsofuse.Anapplicationofuseisdenedasasingleuseofthefullyassembledbreathing
apparatus,wheretheuserbreathesfromtheaircylinder.Itdoesnotincludesystempressurizationforpre-operationalchecks.
5.2 Maintenance tasks
5.2.1 Removing the cylinder
!
WARNING
 High-pressureairreleasemaycauseinjurytotheuserorotherpersonnelnearthebreathingapparatus.Closethecylindervalveandfullyventthesystembeforeattempting
todisconnectanaircylinder.
1. Closethecylindervalveandpressthepurgebutton(Fig1,Item2)tofullyventthesystem.
2. Removetheanti-vibrationstrapfromthecylindervalve(Fig4).
3. Disconnectthecylindervalvefromtherst-stageregulator.
4. Carefullyremovethecylinderfromtheholster.Topreventdamage,ensurethatthehandwheeloftherst-stageregulatorremainsclearofthecylinder.
5.2.2 Air cylinder charging
!
WARNING
 Airqualityforcompressed-aircylindersmustconformtotheminimumgraderequirementsforType1gaseousairasdenedinCGA(CommoditySpecicationforAir)G-7.1
GradeDorhigherquality.
 Ifthebreathingairmoisturecontentexceedsrecommendedlevels,iceparticlescanform,reducingorblockingairow.Watercontentofthebreathingairinanycontainer
mustbechecked.
● Referalsototheinstructionssuppliedwiththecylinderandthechargingunitforrechargingthecylinder.
● Onlychargecompressed-aircylinderswhich:conformtonationalstandards,featuretheoriginalmanufacturer’stestdateandtestmark,havenotexceededthetestdateindicated
onthecylinderbythelasttestingstation,andarenotdamaged.
● Topreventingressofmoistureintothecylinder,ensurethatthecylindervalveremainscloseduntilconnectedtothechargingunit.
● Recharge to the rated working pressure of the cylinder. Dräger recommend a charge rate of 300 psi/minute. Rapid charging will increase the temperature resulting in an
incompletecharge.Recheckatambienttemperatureandtopupthechargeifrequired.
● Topreventoverchargingofthecylinder,Drägerrecommendusingapressure-limitingdeviceonthechargingcompressor.
5.3 Cleaning and disinfecting
!
CAUTION
 Cleaning agents and disinfectants listed below are not manufactured by
Drägerandhavebeenreviewedonlyforcompatibilitywhenusedtocleanor
disinfectthesubjectDrägerproduct(s).Readandcomplywithallinstructions
foruseprovidedbythemanufacturersofsuchagentsanddisinfectants.Dräger
expresslydisclaims all responsibility for any damage, personal injury or loss
resultingfromtheuseofsuchagentsordisinfectants.
 Donotexceed86°F(30°C)forwashing,disinfectingandrinsingsolutions.Do
notexceed140°F(60°C)fordrying,andremovecomponentsfromthedrying
facilityimmediatelywhendry.Dryingtimeinaheateddryermustnotexceed30
minutes.
 Donotimmersepneumaticincleaningsolutionsorwater.
 If water is trapped and then freezes inside the pneumatic system of the
breathing apparatus (such as the lung demand regulator), operation will be
impaired.Prevent any liquid from entering,and thoroughly drythe breathing
apparatusaftercleaningtopreventthisfromoccurring.
Referalsototheinstructionsforthefacemaskandotherassociatedequipment.
5.3.1 Manual cleaning of the breathing apparatus (USA)
Cleaning and disinfecting materials:
● Cleaningagent–1008GreenLiquidHandDishWash
● Disinfectingagent–800Spur-TexDisinfectantCleaner-Deodorant(concentration:
1.6%(2ozpergallon))
● Useonlycleanlint-freecloths.
1. Preparecleaningsolutionaspermanufacturer’sinstructions.Cleanthebreathing
apparatus manually using a cloth moistened with cleaning solution to remove
excessdirt.
2. Preparedisinfectingsolutionaspermanufacturer’sinstructions.Applytoallinternal
andexternalsurfaces,ensuringthatallsurfacesremainvisiblywetfor15minutes.
3. Rinse all components thoroughly with clean water to remove all cleaning and
disinfectingagents.
4. Dryallcomponentsusingadrycloth,inaheateddryerorinair.
5. Contact service personnel or Dräger if disassembly of pneumatic or electronic
componentsisrequired.
5.3.2 Manual cleaning of the breathing apparatus (Canada)
Cleaning and disinfecting materials:
● Cleaningagent–mildsoapsolution
● Disinfectingagent–NeutralDisinfectantCleaner(concentration:0.5%(0.5ozper
gallonor15mlper3.785liters))
● Useonlycleanlint-freecloths.
1. Preparecleaningsolutionaspermanufacturer’sinstructions.Cleanthebreathing
apparatus manually using a cloth moistened with cleaning solution to remove
excessdirt.
2. Preparedisinfectingsolutionaspermanufacturer’sinstructions.Applytoallinternal
andexternalsurfaces,ensuringthatallsurfacesremainvisiblywetfor10minutes.
3. Rinse all components thoroughly with clean water to remove all cleaning and
disinfectingagents.
4. Dryallcomponentsusingadrycloth,inaheateddryerorinair.
5. Contact service personnel or Dräger if disassembly of pneumatic or electronic
componentsisrequired.
6 Storage
Store the equipment between 5 °F and 77 °F (-15 °C and +25 °C). Ensure that the
environmentisdry,freefromdustanddirt,anddoesnotsubjecttheequipmenttowear
ordamageduetoabrasion.Donotstoretheequipmentindirectsunlight.Notealsothe
following:
● Extendtheshoulderstrap,thewaistbeltandtheheadharnessstrapsoftheface
mask.
● Forstorage,placethefacemaskinaprotectivebag(contactDrägerforsupplyofa
suitablebag).
● Routerubberhosesinsuchawaythatthebendradiusisnottooacuteandthehose
isnotstretched,compressedortwisted.
● Fixtheapparatussecurelytoanyraisedmountingpointtopreventitfromfalling.
7 NIOSH Cautions and limitations
D–Air-line respirators can be used only when the respirators are supplied with
respirableairmeetingtherequirementsofCGAG-7.1GradeDorhigherquality.
E–UseonlythepressurerangesandhoselengthsspeciedintheUser’sInstructions.
I– Contains electrical parts that may cause an ignition in ammable or explosive
atmospheres.
J– Failuretoproperlyuseandmaintainthisproductcouldresultininjuryordeath.
M–Allapprovedrespiratorsshallbeselected,tted,used,andmaintainedinaccordance
withMSHA,OSHA,andotherapplicableregulations.
N–Neversubstitute,modify,add,oromitparts.Useonlyexactreplacementpartsinthe
congurationasspeciedbythemanufacturer.
O–RefertoUser’sInstructionsand/ormaintenancemanualsforinformationonuseand
maintenanceoftheserespirators.
S–Specialorcriticaluser’sinstructionsand/orspecicuselimitationsapply.Referto
User’sInstructionsbeforedonning.
7.1 S – Special or critical user’s instructions
● Approvedforuseattemperaturesabove-25°F(-31.7°C).
● During supplied airline respirator (SAR) use, the PAS Colt cylinder valve must
remain closed. If the independent air supply fails, immediately open the cylinder
valve,disconnecttheindependentairsupply,andproceedtofreshair.
● Theindependentairsupplymustmeetthefollowingcriteria:
 ○ Airlinepressureandowrequirements:pressure87to125psi;airowrateat
least550liters/minute.
 ○ Airline hose requirements: 5 feet to 300 feet of Dräger approved hose.
(Important note: The airline hose must not be made up of more than 12
individualhoses.)
8 Disposal
Whenrequired,disposeofthePASColtinaccordancewithnationalorlocalregulations
forwastedisposal.
9 Technical data
● Highpressureconnection:upto3000psi,connectiontoCGA346.
● Lungdemandregulatortofacemaskconnection:push-inconnector.
● Compressed-air cylinder: cylinders are available in aluminium or composite
materials(contactDräger forfulldetails).CylindersfromDrägeraresuppliedfully
charged.
● Independentairsupply:
 ○ Airlinepressureandowrequirements:pressure87to125psi;airowrateat
least550liters/minute.
 ○ Airline hose requirements: 5 feet to 300 feet of Dräger approved hose.
(Important note: The airline hose must not be made up of more than 12
individualhoses.)
● Low-pressurewhistleactivationpressure(iftted)–commencesintherange:72.5
to58psi;ceasesintherange:25to0psi.
10 Contact details
Any issues with the equipment, including damage, malfunction, or failure of the
breathing apparatus that may present a hazard to Dräger US Customer Service –
Phone1-800-858-1737.
Contactwiththecerticationorganizationmaybereachedat:
NIOSH,NPPTL–Phone1-412-386-4000
DraegerSafetyUKLimited
UllswaterClose Tel +441670352891
Blyth,NE244RG Fax +441670356266
UnitedKingdom www.draeger.com