EOS Mythos S35 User manual

Druck-Nr.: 2902 5257
Stand: 48/22
EN
Made in Germany
EOS Mythos S35 / S45
Heater for Sauna Cabins
Installation and Operating Instructions

EN-2 Installation and Operating Instructions - EOS Mythos S35 / S45
EN Documentation
Documentation
Manufacturer
Original installation instructions EN
Copyright for these installation instructions remains with
EOS Saunatechnik GmbH.
The copying and distribution of this document, as well as the use and com-
munication of its contents without express authorization, are not permit-
ted. Compensation will be claimed in the event of infringements.
All rights reserved with regard to patent claims or submission of design or
utility patent.
Characters, symbols and illustrations
Revision history
EOS Saunatechnik GmbH
Schneiderstriesch 1
35759 Driedorf, Germany
Tel. +49 2775 82-514
Fax +49 2775 82-431
Email servicec[email protected]
Web www.eos-sauna.com
Additional information about an operating step
Cross-reference to a page
Read instructions
Result of a step
Table title
Title of figure
≤ ≥ Less than or equal to, greater than or equal to
Date Version Description
6 Dec. 2022 01.10 Nameplate and technical data updated, labeling of
internal wiring changed
1 Feb. 2022 01.00 First version

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-3
Contents
Documentation ..................................................................................................EN-2
1 General safety instructions ..........................................................................EN-5
1.1 Mounting and electrical installation .................................................EN-5
1.2 Operator instruction................................................................................EN-8
1.3 Heater and cabin labels....................................................................... EN-11
1.4 Safety levels.............................................................................................EN-14
1.5 Standards and regulations.................................................................EN-14
2 Identification....................................................................................................EN-15
2.1 Requirements for operation .............................................................EN-15
2.2 Nameplate ...............................................................................................EN-15
2.3 Scope of delivery ...................................................................................EN-16
2.4 Technical data.........................................................................................EN-17
2.5 Intended use ...........................................................................................EN-19
3 Installation ........................................................................................................EN-21
3.1 Specifications for the cabin ...............................................................EN-21
3.1.1 Installation site ......................................................................EN-21
3.1.2 Temperature sensor ............................................................ EN-23
3.1.3 Air inlets and outlets............................................................EN-23
3.1.4 Connecting cables ................................................................EN-24
3.2 Heater guard rail....................................................................................EN-24
3.3 Installing the heater ............................................................................EN-24
3.3.1 Mounting the heater............................................................EN-24
3.3.2 Filling rock stores with stones .........................................EN-28
3.3.3 Inserting cubic stones ........................................................ EN-29
3.4 Warning plates on the cabin.............................................................EN-29
4 Connections......................................................................................................EN-30
4.1 General instructions for electrical installation............................EN-30
4.2 Connections ............................................................................................EN-30
4.2.1 Connection diagrams ..........................................................EN-31
4.3 Establishing an electrical connection ............................................EN-33
4.4 Heating period limitation................................................................... EN-33

EN-4 Installation and Operating Instructions - EOS Mythos S35 / S45
EN
5 Commissioning................................................................................................EN-34
5.1 Starting the heater ................................................................................EN-34
5.2 Water splash ............................................................................................EN-35
6 Maintenance .....................................................................................................EN-36
6.1 Cleaning ....................................................................................................EN-36
6.2 Sauna stones............................................................................................EN-37
6.3 Replacing the heating elements ......................................................EN-38
6.4 Resetting the safety temperature limiter......................................EN-44
6.5 Troubleshooting.....................................................................................EN-45
7 General terms and conditions of service ............................................EN-47
8 Disposal...............................................................................................................EN-50

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-5
General safety instructions
1 General safety instructions
1.1 Mounting and electrical installation
The installation instructions are intended for qualified
personnel familiar with the laws and regulations appli-
cable to electrical installations at the installation site.
Observe the following general safety instructions
during mounting, configuration and commissioning
of the product.
Risk to life and limb and risk of fire
Risk to life and limb from electric shock and fire in the event of im-
proper or faulty electrical connection. This risk also applies follow-
ing completion of the installation work.
The electrical installation of the heater, relay boxes and other
electrical systems or equipment with a fixed mains connection
must only be performed by a trained electrician from an autho-
rized electrical company.
Ensure compliance with the applicable standards and regula-
tions for electrical installation.
The system must be disconnected and removed entirely from
the mains supply before commencing installation and repair
work.
The housing cover may be removed only by an electrician.
Fire hazard from overheating
Insufficient ventilation can lead to device overheating and fire.
Install air inlets and outlets in the cabin.
Observe the cabin manufacturer's safety and installation in-
structions.

EN-6 Installation and Operating Instructions - EOS Mythos S35 / S45
EN General safety instructions
Risk of fire due to sauna stones
It is possible for hot stones or stone pieces to fall out of the rock
store.
For this reason, the sauna heater may not be placed on a floor
made of easily flammable material (e.g., laminate or synthetic
flooring). Ceramic tiles are recommended as a flooring option.
Risk of burns from hot glass
Glass surfaces in the cabin become hot while the sauna is in oper-
ation.
When installing the cabin, ensure that the touchable glass sur-
faces on the outside of the cabin may reach a maximum tem-
perature of 76 °C/168 °F. Appropriate protection may need to
be installed if required.
Risk of burns from hot unit
During operation, the sauna heater may become hot and, if
touched, could cause burns.
Maintain a safe distance.
Sauna cabin and heater
The sauna cabin must be constructed with proper material and
built in a professional manner, and the heater must be suited for
the cabin.
Sauna heaters and control units may only be used in sauna cab-
ins made of suitable, low-resin and untreated material (e.g.,
Nordic spruce).
Multiple heaters may be installed in one sauna if the heater out-
put can properly supply the cabin volume. In this case, depend-
ing on the position, an additional safety temperature limiter
must be installed for each additional heater.

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-7
General safety instructions
The sauna heater is not designed to be installed or set up in an
alcove or under a bench or sloping roof. unless the sauna heater
is specifically designed and approved for this type of installa-
tion.
Receptacles may not be installed inside the sauna cabin.
Each sauna cabin must have air inlets and outlets. The air inlets
and outlets may be installed below or behind the sauna heater,
approx. 5 to 10 cm/2 to 3.9 inches above the floor. The mini-
mum dimensions of the air inlets and outlets can be found here:
2.4 Technical data, EN-17, 3.1.1 Installation site, EN-21.
The exhaust openings are always installed in the lower part of
the wall diagonal to the sauna heater. The supply and exhaust
openings must not be closed. Please observe the instructions
provided by your sauna cabin manufacturer.
Use one of the control units listed below to check and control
the sauna heater. This control unit is fixed to a suitable location
on the cabin's external wall, and the corresponding sensor
housings according to the installation instructions that accom-
pany the control units inside the sauna cabin.
The cabin lighting must be safe for sauna cabin use and in-
stalled in such a way that it can be used safely in a sauna cabin.
Ensure that the heater is installed in compliance with the stan-
dards and legal norms valid in your country.
The cabin door must open outward and must not have a lock
that cannot be opened in the case of failure. We recommend
magnetic or spring locks.

EN-8 Installation and Operating Instructions - EOS Mythos S35 / S45
EN General safety instructions
1.2 Operator instruction
The operator of the sauna cabin must be instructed in the general
safety instructions during commissioning. The operator must be
given a copy of the operating instructions.
The operator must make the end user aware of safety instructions
that are relevant to the end user.
The operator must be familiar with the settings for the heating pe-
riod and understand how it is controlled.
Risk of electric shock
A risk to life and limb from electric shock and fire arises in the event
of improper repair work. This risk also applies after work is com-
pleted.
The housing cover may be removed only by an electrician.
Repairs and installations must only be performed by a trained
electrician.
The system must be disconnected and removed entirely from
the mains supply before commencing repair work.
Use only original spare parts from the manufacturer.
Fire hazard
Objects placed on the heater or protective grilles can
easily be ignited and cause fires.
Attach the heater guard rail.
Do not place objects on the heater.
Fill the stone grate as directed.
Inspect the sauna cabin prior to each commissioning.
If you switch on the heater using pre-set timers or a remote con-
trol, attach a protective cover to the heater or install a suitable
safety system.

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-9
General safety instructions
Health risks
Spending time in a sauna cabin can lead to serious health risks or
even death for persons with health impairments.
Persons with health impairments who spend time in a sauna
must consult a doctor before entering a sauna cabin.
Damage to health
Excessive time spent in a heated sauna cabin can lead to overheat-
ing of the body (hyperthermia), which may cause serious health
problems and even death. Hyperthermia occurs when the core
temperature of the body exceeds the norm by a few degrees.
Symptoms of hyperthermia include fever, dizziness, lethargy,
sleepiness, and fainting. Side effects of hyperthermia include per-
ception disorders, inability to recognize the need to leave the
room, inability to identify imminent danger, harm to the fetus in
the case of pregnant women, inability to physically leave the
room, unconsciousness.
Alcohol, drugs, and medications increase the risk of hyperthermia.
Do not exceed the maximum recommended time in the sauna.
Leave the sauna cabin if your body responds abnormally to the
heat or if you do not feel well.
Avoid alcohol, drugs, and medications when you are using the
sauna.

EN-10 Installation and Operating Instructions - EOS Mythos S35 / S45
EN General safety instructions
Operation by children or persons with reduced mental
capacity
Children and persons with reduced mental capacity can put them-
selves at risk.
Children must be supervised to ensure they do not play with
the unit.
Children under 8 years of age should not operate the sauna
cabin.
The settings for the heating time must only be changed by chil-
dren under 8 years of age if they are supervised by an adult.
The sauna cabin must only be used by persons with reduced
mental capacity, or limited physical or sensory abilities under
supervision or if they have been previously instructed in its use
and understand the risks.
Children and persons who have not received proper instruction
must not clean or service the system.

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-11
General safety instructions
1.3 Heater and cabin labels
UL 875 (Electric Dry-Bath Heaters) requires the following labels to be
affixed.
Heater – left side
Example: EOS Mythos S35
Observe the important additional instructions in the
manual! Suitable for damp location.
Consultez les instructions supplémentaires import-
antes dans le manual! Convient pour un emplace-
ment humide
Print no. 29345280 / 02.22
mm inch
A
B
40
900
1,6
35,4
AA
AA
B
A
A
A
A
4,2 - 6,3 qm x 1,90 m
45,2 - 67,8 sq ft x 6,2 ft
4,7 - 7,4 qm x 1,90 m
50,5 - 79,7 sq ft x 6,2 ft
7,4 - 9,5 qm x 1,90 m
79,7 - 102,3 sq ft x 6,2 ft
9,5 - 13,2 qm x 1,90 m
102,3 - 142 sq ft x 6,2 ft
35 x 5 cm
1,2 x 0,2 ft
35 x 6 cm
1,2 x 0,2 ft
35 x 7 cm
1,2 x 0,3 ft
35 x 9 cm
1,2 x 0,4 ft
Cabin volume
Volumes de cabine
Heater output
Puissance du poêle
Print no. 2934 5281 / 02.22
FOR SUPPLY CONNECTIONS USE ONLY COPPER WIRE CABLE SUITABLE FOR AT
LEAST 90 °C.
POUR LES CONNEXIONS ÉLECTRIQUES PREVOIR UN CABLAGE DE CUIVRE
RÉSISTANT AU MOINS À 90° C .
Location of control unit in a dry area /
Emplacement de l’unité de commande dans une zone sèche
EmoTec USA/CAN D/H
Minimum ventilation
Ventilation minimale
7,5 kW
9,0 kW
12,0 kW
15, kW
WARNING
REDUCE THE RISK OF FIRES
Do Not Install Closer Than 900 mm (or 35,4 inches)
To A Horizontal Surface (Ceiling).
29345271_F38.2_2001xxxx
AVERTISSEMENT
RÉDUIRELE RISQUE D‘INCENDIE
Ne pas installer à moins de 900 mm (ou 35,4 pouces)
d’une surface horizontale (plafond).
29345265_F38.2 / 2001xxxx

EN-12 Installation and Operating Instructions - EOS Mythos S35 / S45
EN General safety instructions
Heater – front and right side
WARNING
REDUCE THE RISK OF ELECTROCUTION
29344837_F38.1_ 20016970
AVERTISSEMENT
RÉDUIRE LE RISQUE D’ÉLECTROCUTION
29345263_F38.1 / 2001xxxx
WARNING
REDUCE THE RISK OF
ELECTROCUTION AND BURNS
Do Not Operate Unless Guard Is In Place.
29344841_F38.3_20016094
AVERTISSEMENT
RÉDUIRE LE RISQUE DE
ÉLECTROCUTION ET BRÛLURES
29345266_F38.3 / 2001xxxx
Sauna heater
Type EOS Mythos S35 XXX
Item.-No. 94 XXXX 00
240 V 2Ph AC 60 Hz XX kW
Made in Germany 00002S-No. 20.22
EOS SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
IPX4
5023683
CONFORMS TO
UL STD 875
CERTIFIED TO
CAN/CSA STD
E60335-1/4E
E60335-2-53
WARNING!
AVERTISSEMENT!
NE PAS PLACER DES OBJETS AU-DESSUS DU POÊLE. IL Y A UN RISQUE D‘IN-
CENDIE SI LE POÊLE EST RECOUVERT.
IL Y A UN RISQUE D‘INCENDIE SI LE COMPARTIMENT DE PIERRES N‘EST PAS
CORRECTEMENT REMPLI.
NE PAC CHAUFFER SANS PIERRES.
Print no. 29345269 / 02.22
DO NOT PLACE ANY OBJECTS ON HEATER. COVERING CAUSES FIRE RISK.
AN INADEQUATELY FILLED ROCK STORE CAUSES FIRE RISK.
DO NOT OPERATEWITHOUT ROCKS.
For household use only
Uniquement pour
usage privé

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-13
General safety instructions
Cabin
Sauna visitor notices must be prominently displayed at eye level on the
outside of the cabin.
CAUTION
REDUCE THE RISK OF FIRE
29344843_F38.5_20016096
ATTENTION
RÉDUIRE LE RISQUE D’INCENDIE
29345268_F38.5 / 2001xxxx
WARNING
REDUCE THE RISK OF OVERHEATING
1. Exit immediately if uncomfortable, dizzy, or sleepy.
Staying too long in a heated area is capable of caus-
2.
3. Check with a doctor before use if pregnant, in poor
health, or under medical care.
4. -
causing unconsciousness.
29344842_F38.4_20016095
AVERTISSEMENT
RÉDUIRE LE RISQUE DE SURCHAUFFE
1. Sortez immédiatement si vous êtes mal à l’aise, étour-
di ou somnolent. Séjourner trop longtemps dans une
2. Surveillez les enfants à tout moment.
3. -
ceinte, en mauvaise santé ou sous traitement médical.
4.
entraîner une perte de conscience.
29345267_F38.4 / 2001xxxx

EN-14 Installation and Operating Instructions - EOS Mythos S35 / S45
EN General safety instructions
1.4 Safety levels
Safety instructions and important operating instructions are classified
according to ANSI Z535.6. Please familiarize yourself with the following
terms and symbols:
WARNING
Warning
Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION
Caution
Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE
Notice
Indicates a hazardous situation which, if not avoided, will result in
damage to the unit.
1.5 Standards and regulations
For an overview of the standards that were observed during design and
construction of the sauna heaters, please refer to the individual product's
technical data sheet that can be downloaded from www.eos-sauna.com.
Local regulations also apply to the installation and operation of heating,
sauna, and steam room systems.

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-15
Identification
2 Identification
EOS Mythos S35/Mythos S45 is an electrically heated sauna heater for Finn-
ish mode available in a variety of output capacities.
2.1 Requirements for operation
The heater must be operated with a control unit:
EOS EmoTec D/H USA/CAN
The control unit is not included in the scope of delivery.
2.2 Nameplate
Nameplate (examples)
A Name
B Model
C Item number
D Electrical connection
E Country of origin
F Manufacturer
G Heater output
H Manufacturing date
I Serial number
Sauna heater
Type EOS Mythos S45 XXX
Item.-No. 94 XXXX 00
208 V 3Ph AC 60 Hz XX kW
Made in Germany 00002S-No. 20.22
EOS SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
IPX4
5023683
CONFORMS TO
UL STD 875
CERTIFIED TO
CAN/CSA STD
E60335-1/4E
E60335-2-53
H I
G
Sauna heater
Type EOS Mythos S35 XXX
Item.-No. 94 XXXX 00
240 V 2Ph AC 60 Hz XX kW
Made in Germany 00002S-No. 20.22
EOS SAUNATECHNIK GmbH, Schneiderstriesch 1, 35759 Driedorf
IPX4
5023683
CONFORMS TO
UL STD 875
CERTIFIED TO
CAN/CSA STD
E60335-1/4E
E60335-2-53
A
B
C
E
F
D
Mythos S45
Mythos S35

EN-16 Installation and Operating Instructions - EOS Mythos S35 / S45
EN Identification
2.3 Scope of delivery
Check the delivery to ensure that all components were delivered and that
they are in proper working order. Contact your distributor if components
are missing or damaged. The heater must not be operated if components
are missing or damaged.
The following parts are included in the scope of delivery:
Scope of delivery
Accessories (optional)
* It is essential that the unit is protected from being touched.
A Cubic stones
B Mythos sauna heater S35 or S45
C Installation and Operating Instructions
Accessories (optional) Item number
EOS heater guard rail (to protect unit from
being touched)*
94.6972
Cubic stones + frame S35 94.5520
Cubic stones + frame S45 94.5521
Stones – grain size 100-150 mm/4-6 in. 94.7340
Safety temperature limiter 160 °C/320 °F
Use only original replacement parts.
Model: see component
mounted in the device
B
C
A

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-17
Identification
2.4 Technical data
Electrical connection data
Only use copper lines that are approved for temperatures of min. 180 °C.
When using 4 to 6-core cables, the type of AWG cable specified in the table
increases by one unit.
Example: AWG 12 > AWG 10.
All line cross-section specifications are the minimum cross-sections for the
copper line.
All line cross-section specifications are the minimum cross-sections for the
copper line.
The following fuses are permitted:
Class G, H, J, K
Type S plug-in fuse
Edison base
Heater
Heater type Heater
output
Connection
voltage
Connecting
cable Fuse
Mythos S35 7.5 kW 208 V 12 AWG 50 A
Mythos S35 7.5 kW 240 V 12 AWG 20 A
Mythos S35 9.0 kW 208 V 12 AWG 35 A
Mythos S35 9.0 kW 240 V 12 AWG 20 A
Mythos S45 12 kW 208 V 12 AWG 30 A
Mythos S45 15 kW 208 V 12 AWG 35 A
Heater type Heater
output
Unit dimensions
HxWxD
Weight
Without
stones
Stone filling
Mythos S35 7.5 kW 84 x 42 x 37 cm
2.8 x 1.4 x 1.2 ft.
33.5 kg/74 lbs. 35 kg/77 lbs.
Mythos S35 9.0 kW
Mythos S45 12 kW 84 x 50x 37 cm
2.8 x 1.6 x 1.2 ft.
39.5 kg/87 lbs. 45 kg/99 lbs.
Mythos S45 15 kW

EN-18 Installation and Operating Instructions - EOS Mythos S35 / S45
EN Identification
Cabin
Heater type Heater
output Cabin – volume Min. dimension – venti-
lation
Mythos S35 7.5 kW 4.2-6.3 sq. m x 1.9 m
45.2-67.8 sq. ft. x 6.2 ft.
35 x 5 cm
1.2 x 0.2 ft.
Mythos S35 9.0 kW 4.7-7.4 sq. m x 1.90 m
50.5-79.7 sq. ft. x 6.2 ft.
35 x 6 cm
1.2 x 0.2 ft.
Mythos S45 12 kW 7.4-9.5 sq. m x 1.90 m
79.7-102.3 sq. ft. x 6.2 ft.
35 x 7 cm
1.2 x 0.3 ft.
Mythos S45 15 kW 9.5-13.2 sq. m x 1.9 m
102.3-142 sq. ft. x 6.2 ft.
35 x 9 cm
1.2 x 0.4 ft.

EOS Mythos S35 / S45 - Installation and Operating Instructions EN-19
Identification
2.5 Intended use
This heater is intended solely for the purpose of heating sauna cabins,
together with a suitable control unit.
EOS Mythos S35/Mythos S45 is suitable for private and commercial use.
Neither heater model is suitable for outdoor use. They may
only be operated indoors in buildings. They may not be
exposed to environmental conditions such as extreme humid-
ity and moisture or the possible formation of condensation or
corrosive substances in the ambient air, as well as other weather condi-
tions.
Any use beyond this is considered improper use. Proper use also includes
compliance with operating, maintenance and servicing requirements.
The manufacturer is not responsible for unauthorized modifications and
damages resulting from these modifications; the person modifying the
equipment alone shall bear the associated risk.
Foreseeable misuse
The following are considered instances of foreseeable misuse:
The device does not contain a time-controlled circuit breaker. The con-
trol unit, which ensures an all-pole disconnection of the device, must
control the heating period limitation according to the standard specifi-
cation. It must not be possible to override this time limit.
There is no heater guard rail (to protect unit from being touched)
attached to the cabin. See 3.2 Heater guard rail, EN-24.
The cabin volume does not match the heater output.
The unit is operated without knowledge of or compliance with the
safety instructions.
Operating, service and maintenance requirements are not observed.
The unit is operated by children or persons with reduced mental capac-
ity or by persons who have not been thoroughly instructed in its use.

EN-20 Installation and Operating Instructions - EOS Mythos S35 / S45
EN Identification
General instructions
Please note that an optimal sauna climate can be achieved only if the
cabin with its air inlets and outlets, the sauna heater, and the control
unit are synchronized.
Observe the specifications and information provided by your sauna
retailer.
The sauna heaters heat the sauna cabin with heated convection air.
Fresh air is drawn in through the air inlet. It is warmed and rises (convec-
tion) and is then circulated in the cabin. Some of the used air is pushed
out of the cabin through the cabin's air outlet. This creates a typical
sauna climate in your sauna.
All temperatures that can be set via the control unit are tested accord-
ing to UL875 or CSA C22.2#60335-1:2016Ed.2 and CAN/CSA E60335-2-
53*AEI.
It must be noted that there is a temperature drop between the ceiling
and the foot area inside the sauna cabin. The measured and set values
are taken from the ceiling. Thermometers below the ceiling will there-
fore register lower temperatures. When the max. temperature is set for
the area around the upper sauna bench, the bathing temperature is
typically between 80 °C/176 °F and 90 °C/194 °F.
The first time the cabin is heated, you may notice a slight odor resulting
from the evaporation of consumables used in the manufacturing pro-
cesses. Air out your cabin once it has been heated and before using the
sauna.
Other manuals for Mythos S35
1
This manual suits for next models
1
Table of contents
Other EOS Heater manuals

EOS
EOS Vision User manual

EOS
EOS Bi-O Tec User manual

EOS
EOS 46.U Planning guide

EOS
EOS Gracil Series User manual

EOS
EOS Herkules XL S120 HD User manual

EOS
EOS IRS 30 Keramik Planning guide

EOS
EOS Stativ Terra Vita II User manual

EOS
EOS THERMAT Owner's manual

EOS
EOS Mythos S34 User manual

EOS
EOS Saunadome II User manual