Translation of the original instructions
1 Applicable documents
All available documents for the product èwww.festo.com/pk.
2 Safety
2.1 Safety instructions
– Do not connect or disconnect plug connector when powered.
– Only assemble the product on components that are in a condition to be safely
operated.
2.2 Intended use
Connection of motor EMME-AS to motor controller CMMP-AS at connection X2B.
3 Configuration
3.1 Product design
1Socket M12, 8-pin, A-coded (1x)
2Plug Sub-D, 15-pin (1x)
3Cable (1x)
4Screw-type lock
5Screw (2x)
Fig. 1
6Filter (1x)
CAMF-C5-FC
7Screw (4x)
Fig. 2
The filter6 is only required for cable lengths of ³10m.
3.2 Contact assignment
Electrical connec
tion1
Field device side
Pin Signal Pin Electrical connec
tion2
Controller side
1 GND 3
2 Us 10
3 Data+ 12
4 Data– 5
5 +SIN 15
6 REFSIN 8
7 +COS 14
8 REFCOS 7
Tab. 1 Contact assignment
4 Mounting
4.1 Mounting of electrical connection1
Fig. 3
1. Align socket1 with the pins of the plug(A).
2. Lay out encoder cable3 so it is not twisted.
3. Connect socket1 to the plug(A).
4. Tighten screw-type lock4. Tightening torque: 0.4Nm±20%
ÄScrew-type lock4 is at distancex (approx.5.6mm) from the plug con-
nector(B).
Fig. 4
4.2 Mounting of electrical connection2
With cable lengths <10m
1. Align the plug2 to match the socket.
2. Insert the plug2 into the socket.
3. Tighten5 screws. Tightening torque: 0.1Nm±20%
With cable lengths ³10m
1. Align the plug2 to match the socket.
2. Insert the plug2 into the socket.
3. Mount filter6 between the controller (Anschluss X2B) and the plug2.
4. Tighten5 screws. Tightening torque: 0.1Nm±20%
5. Tighten7 screws. Tightening torque: 0.1Nm±20%
4.3 Mounting in energy chain
1. Lay the chain out lengthwise.
2. Place the cables in the chain, making sure they are not twisted.
3. Separate cables from each other using separators/drill holes.
4. Do not connect cables together.
Fig. 5
5. Maintain spaceX. X>10% of the cable diameterD.
If the chain is suspended vertically: increase the spaceX.
Fig. 6
6. Align chain in the operating position:
– Make sure that the radius is greater than the bending radius R of the
cables.
– Cables can move freely in the bending radiusKR of the energy chain.
ÄCables are not forced through the chain.
7. Mount the energy chain ècorresponding instructions.
8. Fasten cables:
– At both ends of the chain in case of short energy chains
– Only at the driver end in the case of long, sliding energy chains
8107328
NEBMM12G8E...S1G15
Encoder cable
8107328
2019-05b
[8107330]
Instructions|Assembly
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com