manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. FingerTec
  6. •
  7. IP Access Controllers
  8. •
  9. FingerTec FaceID2 User manual

FingerTec FaceID2 User manual

Other FingerTec IP Access Controllers manuals

FingerTec H3i User manual

FingerTec

FingerTec H3i User manual

FingerTec TA700W User manual

FingerTec

FingerTec TA700W User manual

FingerTec s-Kadex User manual

FingerTec

FingerTec s-Kadex User manual

FingerTec R2 User manual

FingerTec

FingerTec R2 User manual

FingerTec H3i User manual

FingerTec

FingerTec H3i User manual

FingerTec TA100C User manual

FingerTec

FingerTec TA100C User manual

FingerTec AC900 User manual

FingerTec

FingerTec AC900 User manual

FingerTec AC900 User manual

FingerTec

FingerTec AC900 User manual

FingerTec TA100C User manual

FingerTec

FingerTec TA100C User manual

FingerTec R3 User manual

FingerTec

FingerTec R3 User manual

FingerTec AC100C User manual

FingerTec

FingerTec AC100C User manual

FingerTec TA500 User manual

FingerTec

FingerTec TA500 User manual

FingerTec AdapTec Plus Assembly instructions

FingerTec

FingerTec AdapTec Plus Assembly instructions

FingerTec H2i Operating and maintenance instructions

FingerTec

FingerTec H2i Operating and maintenance instructions

FingerTec Keylock 8800 User manual

FingerTec

FingerTec Keylock 8800 User manual

FingerTec H3i User manual

FingerTec

FingerTec H3i User manual

FingerTec k-Kadex User manual

FingerTec

FingerTec k-Kadex User manual

FingerTec Face ID3 User manual

FingerTec

FingerTec Face ID3 User manual

FingerTec R2c User manual

FingerTec

FingerTec R2c User manual

FingerTec TA700W User manual

FingerTec

FingerTec TA700W User manual

FingerTec i-Kiosk 100 User manual

FingerTec

FingerTec i-Kiosk 100 User manual

FingerTec Face ID2 User manual

FingerTec

FingerTec Face ID2 User manual

FingerTec R2 User manual

FingerTec

FingerTec R2 User manual

FingerTec TimeLine 100 User manual

FingerTec

FingerTec TimeLine 100 User manual

Popular IP Access Controllers manuals by other brands

Ava bqt miPASS BT510 installation guide

Ava

Ava bqt miPASS BT510 installation guide

ZKTeco SpeedFace-V5L user manual

ZKTeco

ZKTeco SpeedFace-V5L user manual

2N Access Unit Configuration manual

2N

2N Access Unit Configuration manual

Kedacom KSCA120 Series quick start guide

Kedacom

Kedacom KSCA120 Series quick start guide

H3C WX2880X installation guide

H3C

H3C WX2880X installation guide

G4S S870-EX Installation and user instructions

G4S

G4S S870-EX Installation and user instructions

PRASTEL M2000PE manual

PRASTEL

PRASTEL M2000PE manual

Allegion interflex IF-281 Cylinder manual

Allegion

Allegion interflex IF-281 Cylinder manual

TECOM TS1067E manual

TECOM

TECOM TS1067E manual

Fermax Memokey 100C Installer manual

Fermax

Fermax Memokey 100C Installer manual

Fermax CITYLINE MEMOKEY User& installer's manual

Fermax

Fermax CITYLINE MEMOKEY User& installer's manual

Civintec CV9601T-T-1F installation manual

Civintec

Civintec CV9601T-T-1F installation manual

BioMax N-X90W user manual

BioMax

BioMax N-X90W user manual

ZKTeco OP-200 quick start guide

ZKTeco

ZKTeco OP-200 quick start guide

H3C WX5002ACCESSCONTROLLER installation manual

H3C

H3C WX5002ACCESSCONTROLLER installation manual

Conrad Electronic KeyMatic CAC operating instructions

Conrad Electronic

Conrad Electronic KeyMatic CAC operating instructions

IDTECK Star 100R manual

IDTECK

IDTECK Star 100R manual

AKCP SP+ manual

AKCP

AKCP SP+ manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

4 feet / 1.2 meter
(recommended)
USB Port
Wiegand OUT RS232
RS232
cable
RS485
485-
485+
GND
TXD
RXD
WD0
WD1
SGND
GND
3rd party controller
with 26 bits Wiegand
input
RX+
RX-
1. RS485 Single Connection
RS232/RS485
Data Converter
RX+
RX-
RS232/RS485
Data
Converter
2. RS485 Network Connection
485+
485-
485+
485-
485+
4851
GND
+12V DC12V 3A
Power Supply
........
RS485-Wiegand Connection Port
Power Port (B)
TCP/IP Port
Access Control Port
External
Alarm Port
(FMM)
Power Port (A)
Step 1
Determine the Installation Location
• Avoid installing the terminals in locations that have contact with
strong light source (e.g direct sunlight, spotlight, fluorescent
light, etc)
• Avoid installing the terminals in locations with high moisture or
condensation levels in the air
• The recommended installation height of the terminal from the
ground to the camera is 1.2 meter.
Step 2
Mount Terminal on a Wall
1. Avoid strong sunlight
2. Install the terminal 1.2m from the ground level (measure the
height from the ground to the face camera)”
After measuring the height accordingly and make relevant markings on
the wall, drill the screws into the wall to secure the back plate.
Attach the terminal to the back plate and tighten the screws.
Refer to Appendix II for dimensions and measurements of installation.
Installation Guide
Face & Fingerprint Recognition System for
Door Access & Time Attendance
Step 3
Wiring for Power Supply
Use the power adapter provided in the package and insert the
power adapter to the Power Port (A).
OR
Use power cables (black and red) to connect to a linear power sup-
ply with specifications of 12VDC 3A to Power Port (B).
© 2017 Timetec Computing Sdn Bhd. All rights reserved.• 032017
Step 4
Setting Up Data Communications
(Skip this step if you are using USB ash disk to transfer data)
The data communication ports are positioned at the rear of the
terminal, please refer to the diagram shown on Step 3 to deter-
mine the wiring. Plug the communication jacks (TCP/IP, RS232 or
RS485) to the corresponding ports.
TCP/IP – LAN Connection
For TCP/IP connection, plug the special RJ45 jack into the TCP/IP
(LAN) Port of the terminal. Connect the other end (normal RJ45
jack) to the local area network hub or a PC. Configure the device
ID, IP address, subnet mask and Gateway in the terminal (refer to
the hardware user manual for details).
RS232 – Serial Port Connection
Plug the communication jack that is provided in the package to
connect to the communication port of the terminal. Select wires
with label RX, TX and GND, and connect the other end of these
wires to a DB9 female connector. Configure the device ID and
baudrate of the terminal (refer to the hardware user manual for
details). Use the normal RS232 cable to plug into the RS232 port
of the terminal.
RS485 – Serial Port Connection
Plug the communication jack that is provided in the package to
connect to the communication port of the terminal. Select wires
with label RS485+, RS485- and GND, and connect the other end
of these wires to an RS232/485 data converter. Connect the other
end of the data converter to a DB9 female connector. Configure
the device ID and baudrate of the terminal (refer to the hardware
user manual for details).
Step 5
Finalizing the installation
1. Check that all cable connections are done correctly.
2. Attach the terminal to the corresponding back plate,
tighten the screws to fix the terminal on a wall.
3. Switch on the power to the terminal.
4. Start using it.
Other Accessories
Note: All Accessories are offered at http://accessory.fingertec.com
AdapTec Plus
The AdapTec Plus is a 12VDC power supply inclusive of a
110~240VAC switching linear power. The AdapTec Plus supplies
12VDC power to the FingerTec terminal and door lock system as
well as charges a 12VDC 7.0Ah backup battery simultaneously.
During an event of a power failure, the back up battery automati-
cally provides power to the terminal and maintains the door lock
system. The AdapTec Plus also prevents a secured door from being
opened if it has been tampered with.
DIY Display Stand
If the Face ID 2 is only used for time & attendance purpose, you can
consider this display stand instead of mounting the terminal on a
wall. The display stand of Face ID 2 can be adjusted to the desired
height and it is portable.
Door Lock Accessories
FingerTec offers various door locks accessories to complement the
door access product range.
Diagram1 • Normally Close (NC)
Diagram 2 • Normally Open (NO)
Diagram 3 • Other Accessories
NO2
COM2
NC2
SEN
GND
BUT
NO1
COM1
NC1
GND
+12V
Release Button
EM Lock
Emergency
Break Glass
Overwrite Key
Switch
+
_
1
3
B
D
DC12V
3A
_ +
NO2
COM2
NC2
SEN
GND
BUT
NO1
COM1
NC1
GND
+12V
Release Button
EM Lock
Emergency
Break Glass
Overwrite Key
Switch
+
_
2
3
A
C
DC12V
3A
_ +
Use either Type NO or Type NC alarm device.
NO2
COM2
NC2
SEN
GND
BUT
NO1
COM1
NC1
GND
+12V
_ +
Alarm Device
Type NC dry contact
Alarm Device
Type NO drycontact
Door Sensor
DC12V
3A
Door Lock Connectors
The terminal will trigger the alarm output
(NO or NC) in the following situations:
• Door forced open (A door sensor must
be installed)
• Door open time out (A door sensor must
be installed)
• Terminal has been illegally dismantled
Alarm System
NO Type – NO2 – COM2
NC Type – NC2- COM2
Door Sensor (SEN-GND)
Release Button (BUT-GND)
Dry Contact
(Independent power supply for door
lock)
• NO type door lock (NO1-COM)
• NC type door lock (NC1-COM)
Power Contact
(Using power from terminal to power
on door lock)
• NO type door lock (NO1-GND)
• NC type door lock (NC1-GND)
Dry Contact (independent power
supply for door lock)
• NO type door lock (NO1-COM)
• NC type door lock (NC1-COM)
Power Contact (using power from
terminal to power on door lock)
• COM1 - +12V
WIRING PORT USAGE
NO2
COM2
NC2
SEN
GND
BUT
NO1
NC1
COM1
Appendix II
Terminal Dimensions and Measurements
Appendix I
Power Supply & Door Lock System Wiring Diagrams
Front View of a Back Plate