EQUIPMENT: DUO-CEL WRITTEN BY: RKP
PUBLICATION: OM_DUO-CEL_INST CHECKED BY: AJC
ISSUE No. & DATE: 2 13/10/10
PAGE 2 of 30
List of Contents
1. LIST OF FIGURES..................................................2
2. INTRODUCTION ....................................................3
2.1 PANEL IDENTIFICATION.........................................3
3. PANEL CIRCUIT DETAILS..................................3
3.1 AUXILIARY SUPPLY...............................................3
3.2 FIRE SIGNAL OUTPUT............................................3
3.3 FIRE RELAY OUTPUT.............................................3
3.4 FAULT RELAY OUTPUT..........................................3
3.5 REMOTE CONTROL INPUT......................................4
3.5.1 Class Change............................................4
3.5.2 Alert ..........................................................4
3.5.3 Evacuate....................................................4
3.5.4 Silence Alarms ..........................................4
3.5.5 Reset..........................................................4
3.6 OPEN COLLECTOR OUTPUTS .................................5
3.6.1 Disabled Output........................................5
3.6.2 Evacuate Output........................................5
3.6.3 Buzzer Active Output.................................5
3.7 SOUNDER CIRCUITS...............................................5
3.8 ELECTRICAL DESIGN OF DETECTION ZONES..........5
3.8.1 Standard Panel Default Zone
Configuration.........................................................6
3.8.2 Standard Panel Resistor Zone
Configuration.........................................................6
3.8.3 Twin-Wire Panel Zone Configuration.......6
3.8.4 Maximum Number of Devices on a Zone ..6
3.9 PANEL TO REPEATER WIRING................................9
4. INSTALLATION AND COMMISSIONING
PROCEDURE OVERVIEW................................10
5. INSTALLATION....................................................10
ELECTRICAL SAFETY.................................................10
5.1 PRE-INSTALLATION CHECKS ...............................12
5.1.1 DUO-CEL Panel Installation Instructions
12
5.1.2 Battery removal & Replacement.............14
5.1.3 DUO-CEL Repeater Installation
Instructions ..........................................................16
6. PANEL COMMISSIONING .................................16
6.1 INTRODUCTION....................................................16
6.2 COMMISSIONING CHECKLIST...............................16
6.3 AN OVERVIEW OF THE COMMISSIONING
PROCEDURE......................................................16
6.4PRE-COMMISSIONING WIRING CHECK.................17
6.5 POWERING UP......................................................17
6.6 PANEL CONFIGURATION......................................18
6.6.1 Basic Default Configuration ...................18
6.6.2 Site-Specific Configuration.....................18
7. OPERATING THE ENGINEER’S FUNCTIONS
.................................................................................18
7.1 ZONE DEPENDENCY (COINCIDENCE)....................18
7.1.1 Zone Dependency selection.....................18
7.2REPEATER CONFIGURATION................................19
7.2.1 Repeater selection...................................19
7.3 INVALID CONFIGURATION CONDITIONS:..............19
7.4 ZONE 1NON-LATCH OPERATION .........................19
7.5 RESISTOR EOL....................................................19
7.6 ALERT MODE ......................................................19
7.7 SELECTABLE ZONAL OR GENERAL ALARM
SOUNDER OPERATION........................................20
7.8 BUZZER DISABLE.................................................20
7.9 EARTH FAULT MONITORING.................................20
8. COMMISSIONING THE PANEL ........................20
8.1 GENERAL ALARM CIRCUITS ................................20
8.2 DETECTION ZONES...............................................20
8.2.1 Zone Fault Indications ............................20
8.2.2 Zone Fire Indications..............................21
8.3 REMOTE CONTROL INPUT ....................................21
8.4 FIRE SIGNAL OUTPUT ..........................................21
8.5 ANCILLARY OUTPUTS ..........................................22
8.6 REPEATERS ..........................................................22
8.6.1 Repeater Testing......................................23
8.7 POWER SUPPLY UNIT...........................................23
8.8 FINAL DRESSING OF THE CABLES ........................23
8.9 SITE CONFIGURATION..........................................23
9. SYSTEM HANDOVER..........................................24
10. SYSTEM MAINTENANCE.................................24
11. USER INDICATIONS..........................................25
12. USER CONTROLS...............................................26
13. PCB LAYOUTS.....................................................27
14. GENERAL ASSEMBLY DRAWING.................29
15. ALARM COUNT DISPLAY................................30
1. List of Figures
FIGURE 1–FIRE SIGNAL OUTPUT CONNECTIONS.............3
FIGURE 2–RELAY CONTACT CONNECTION DETAILS........4
FIGURE 3–REMOTE CONTROL I/P CONNECTIONS............5
FIGURE 4–ALARM CIRCUIT CONFIGURATION..................5
FIGURE 5–TWIN-WIRE EOL DEVICE ..............................6
FIGURE 6–STANDARD ZONE WIRING DIAGRAM.............7
FIGURE 7–RESISTOR EOL ZONE WIRING DIAGRAM.......7
FIGURE 8–TWIN-WIRE ZONE WIRING DIAGRAM............8
FIGURE 9–ALARM CIRCUIT WIRING DIAGRAM ..............8
FIGURE 10 –REMOTE INDICATORS WIRING DIAGRAM.....9
FIGURE 11 –REPEATER WIRING DIAGRAM......................9
FIGURE 12 –BAQ35T24 1.5A POWER SUPPLY
CONNECTIONS............................................15
FIGURE 13 –PANEL CONTROL BOARD AND PCB COVER 27
FIGURE 14 –REPEATER CONTROL BOARD AND PCB
COVER ........................................................28
FIGURE 15 –ALARM COUNT LED ASSIGNMENT ............30