MANUAL ZIGBEE CONFIGURATION
BINDING BETWEEN THE GWA1521 ACTUATOR AND THE GWA1502 INTERFACE
TECHNICAL MANUAL

page 2| ZIGBEE | TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502

TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502 | ZIGBEE | page 3
CONTENTS
CONTENTS .............................................................................................................................................................. 3
AIM OF THIS PUBLICATION ................................................................................................................................. 4
ZIGBEE KEY –USEFUL TERMS .......................................................................................................................... 4
TECHNICAL FILES ................................................................................................................................................. 5
DIMENSIONS........................................................................................................................................................... 6
BREAKDOWN OF THE ZIGBEE DEVICES.......................................................................................................... 7
ELECTRIC DIAGRAMS .......................................................................................................................................... 8
CONFIGURATION................................................................................................................................................... 9
CREATING AND JOINING TO THE ZIGBEE NETWORK:.....................................................................................................9
ASSOCIATION BETWEEN DEVICES:................................................................................................................................. 9
ACTUATOR PARAMETERS (GWA1521)............................................................................................................10
HOW TO SET THE DURATION OF THE TIMING................................................................................................................10
INTERFACE PARAMETERS (GWA1502): ..........................................................................................................11
INTERFACE (GWA1502) FACTORY RESET......................................................................................................12
ACTUATOR (GWA1521) FACTORY RESET.......................................................................................................12

page 4| ZIGBEE | TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502
AIM OF THIS PUBLICATION
This manual is designed for the installer responsible for configuring the ZigBee system.
It explains how to make the binding between the GWA1521 and GWA1502 devices.
ZIGBEE KEY –USEFUL TERMS
Binding:
The association between an actuator and a sensor in order to carry out a
certain function
Coordinator:
The ZigBee device that carries out the following tasks:
1. Create the ZigBee network
2. Define the optimal frequencies that the network will use
3. Generate the PAN (Personal Area Network)
4. Generate the decoding key used by that specific network
5. Assign a short address to all the devices which are part of that ZigBee
network
6. Transmit the decoding key to those devices
End device:
Battery-controlled ZigBee devices
Joining:
Operation via which a ZigBee device becomes part of a ZigBee network
Permit Join:
Operation via which a ZigBee network coordinator opens that network so that
one ZigBee device or more (not yet part of the network) can become part of it
Router:
Any device of a ZigBee system that is not the coordinator or an end device
(battery-controlled). Router devices forward messages within the ZigBee
network, facilitating communication between devices.

TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502 | ZIGBEE | page 5
TECHNICAL FILES
GWA1521
CATEGORY:
General loads actuator
SUPPLY VOLTAGE:
230V AC / 50Hz
OUTPUT CONTACTS:
1 NO 10A (AC1) 230V AC
NO.OF OUTPUT CHANNELS:
1
MAX.DISPERSIBLE POWER (W):
2W
MAX.MOTOR POWER:
500W
OUTPUT POWER:
3 dBm
CFL LAMPS:
150W
LOADS CONTROLLED BY TOROIDAL TRANSFORMERS:
450W
LOADS CONTROLLED BY ELECTRONIC
TRANSFORMERS:
600W
230V HALOGEN INCANDESCENT LAMPS:
2300W
230V LED LAMPS
150W
DEGREE OF PROTECTION:
IP20
OPERATING TEMPERATURE:
[-5°; +45°C]
STORAGE TEMPERATURE:
[-25°; +70°C]
RELATIVE HUMIDITY (NON-CONDENSATIVE):
Max. 93%
DIMENSIONS LX HX D(MM):
42x40x20
COMMUNICATION PROTOCOL:
ZigBee (IEEE 802.15.4)
REFERENCE STANDARDS:
2014/53/EU
GWA1502
CATEGORY:
Contact interface
SUPPLY VOLTAGE:
230V AC –50 Hz
INPUT VOLTAGE:
230V AC
OUTPUT POWER:
8 dBm
NO.OF INPUT CHANNELS:
2
MAX.CABLE LENGTH:
/
DEGREE OF PROTECTION:
IP20
STORAGE TEMPERATURE:
[-25°; +70°C]
OPERATING TEMPERATURE:
[-5°; +45°C]
RELATIVE HUMIDITY (NON-CONDENSATIVE):
Max. 93%
DIMENSIONS LX HX D(MM):
42x40x20
COMMUNICATION PROTOCOL:
ZigBee (IEEE 802.15.4)
REFERENCE STANDARDS:
2014/53/EU, EN 60669-2-1, EN 60669-1, ETSI EN
300-328

page 6| ZIGBEE | TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502
DIMENSIONS
GWA1521
GWA1502

TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502 | ZIGBEE | page 7
BREAKDOWN OF THE ZIGBEE DEVICES
GWA1502
A1. DIP-switch with 4 one-way switches
A2. Miniature button key for joining functions
A3. Status LED
GWA1521
A1. DIP-switch with 3 one-way switches
A2. Miniature button key for joining functions
A3. Status LED

page 8| ZIGBEE | TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502
ELECTRIC DIAGRAMS
GWA1502
L. Power supply neutral
N. Power supply phase
I1. Channel 1 input
I2. Channel 2 input
GWA1521
N. Power supply neutral
L. Power supply phase
1. Output common wire
2. NO output
I1. Local command input

TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502 | ZIGBEE | page 9
CONFIGURATION
If the ZigBee network hasn't yet been created, proceed as follows:
1. Choose which device will have the role of coordinator
2. Activate the procedure to create the ZigBee network via the coordinator
3. After creating the network, activate Permit Join
4. Power the devices that you want to join to the network (GWA1521 and GWA1502)
5. Make the binding between the GWA1521 and GWA1502 devices
If the ZigBee network has already been created, only the last three points of the list are required:
1. After creating the network, activate Permit Join
2. Power the devices that you want to join to the network (GWA1521 and GWA1502)
3. Make the binding between the GWA1521 and GWA1502 devices
Creating and joining to the ZigBee network:
1. Make sure the actuator is in its factory-set condition (if it isn't, make a factory reset)
2. The LED on the device must have a fixed red light
3. Press the Permit Join activation button key quickly for 3 times. The LED will turn green for a few
seconds and then begin flashing. From this moment, Permit Join is activated for 15 minutes (this
device is now the network coordinator).
4. Make sure the interface is in its factory-set condition (if it isn't, make a factory reset)
5. When the device is powered, a scan will be launched (red LED) to identify an open ZigBee network
6. When the association has been made, the status LED will begin flashing red (or it will switch off)
7. Briefly press the button key of the actuator (network coordinator) to close the network
Association between devices:
1. On the GWA1521 actuator, bring the dip-switches to the positions shown B6
2. The status LED will have a fixed yellow light
3. Press the button connected to the actuator on local input I1
4. The status LED will make a double yellow flash and this will continue cyclically
5. On the GWA1502 interface, bring the dip-switches to the positions shown B10
6. The status LED will turn yellow
7. Now use the button key connected to the interface that you want to associate (I1 or I2).
8. The identification phase will normally terminate automatically (the LED will have a fixed yellow light
again). If this doesn't happen, wait 3 minutes.
9. Set the dip-switches on the basis of the functions required

page 10 | ZIGBEE | TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502
ACTUATOR PARAMETERS (GWA1521)
To manually select the local input functions, bring the dip-switch to position B1, B2 or B3
#
LOCAL INPUT
OPERATING MODE
DESCRIPTION
IMAGE
B1
monostable
(push-button)
- when the contact closes, the
current relay status is inverted
- when the contact opens, no
command is sent
B2
bistable (one-
way switch)
- the current relay status is
inverted both when the contact
closes and when it opens
B3
timing
- when the contact closes, relay
timing is activated
- when the contact opens, no
command is sent
The selected position merely determines the behaviour of the local input, it doesn't influence overall
product operation.
How to set the duration of the timing
The duration of the timing function activation time (stair raiser light) can be modified as follows:
1. Bring the dip-switches to the position shown to enter activation time
configuration mode
2. Wait for the output contact to open (if it was closed)
3. Briefly close the local input contact (I1) to start the activation time count; the output contact will be
closed
4. When the required time has passed, briefly close the local input contact (I1) to end the count and
save the new activation time value; the output contact will be opened

TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502 | ZIGBEE | page 11
INTERFACE PARAMETERS (GWA1502):
POSITION
CHANNEL 1MODE (L1)
CHANNEL 2MODE (L2)
B1
Independent push-button
Independent push-button
B2
Combined push-buttons
Combined push-buttons
B3
One-way switch (toggle)
One-way switch (toggle)
B4
One-way switch (on/off)
One-way switch (on/off)
B5
Scene
Scene
B6
Independent push-button
One-way switch (toggle)
B7
Scene
Independent push-button
B8
Timed push-button
Independent push-button
Depending on the operating mode selected and the actuators associated, the behaviour of each channel
upon the closure/opening of the corresponding input is as follows:
MODE
ASSOCIATION WITH ON/OFF ACTUATOR
Independent push-button
•Closure: inversion of current load status (toggle)
•Opening: no effect
Combined push-button
•Closure: sends ON if channel 1, OFF if channel 2
•Opening: no effect
Toggle switch
•Closure and opening: inversion of current load status (toggle)
On/Off switch
•Closure: sends ON
•Opening: sends OFF
Scene
•Long press: scene 1 learning if channel 1 / scene 2 learning if
channel 2
•Short press: scene 1 execution if channel 1 / scene 2 execution if
channel 2
Timed push-button
•Closure: starts timing
•Opening: no effect

page 12 | ZIGBEE | TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502
INTERFACE (GWA1502) FACTORY RESET
Press and hold the Permit Join activation push-button (A2) for at least 10 seconds. The status
LED will flash red and green alternately for 3 seconds, then become red fixed.
ACTUATOR (GWA1521) FACTORY RESET
Press and hold the Permit Join activation push-button (A2) for at least 10 seconds. The status
LED will flash red and green alternately for 3 seconds, then become red fixed.

TECHNICAL MANUAL: BINDING BETWEEN GWA1521 AND GWA1502 | ZIGBEE | page 13
LAST REVISION 07/2020 code 70194238
Other manuals for Chorus GWA1521
2
This manual suits for next models
1
Table of contents
Other Gewiss Controllers manuals

Gewiss
Gewiss GW96 752 User manual

Gewiss
Gewiss Chorus GW 10 568 User manual

Gewiss
Gewiss Chorus GW 10 766 User manual

Gewiss
Gewiss Chorus GW 10 801 User manual

Gewiss
Gewiss Chorus GW 10 766 User manual

Gewiss
Gewiss Chorus GWA1521 User manual

Gewiss
Gewiss zigbee CHORUS GWA1531 User manual

Gewiss
Gewiss Chorus GW 90 835 User manual

Gewiss
Gewiss Chorus GWA1521 User manual

Gewiss
Gewiss CHORUS GWA9140 User manual