T04
99
4000
Quick Guide T04
Cat. No. : T04
Serial No. Installation Date.
Max. RPM 4,000 rpm
Max. RCF
2,075 xg
Timer
< 100 min or
continuous
Display & Control
Setting RPM / RCF, Time, ACC / DEC
Touch RPM / RCF,
Time, ACC / DEC
Set the desired values by
touching the Up, Down button
Program SAVE / CALL
Touch the Up, Down button to set the desired program number
Touch once : CALL / Touch twice : SAVE(Up to 30)
Display
Status of Speed(RPM / RCF)
Program SAVE/CALL
Touch once : CALL/
Touch twice : SAVE(Up to 30)
Setting Time
Touch once : CALL/
Touch twice : SAVE(Up to 30)
Display window
Status of Time (MIN / SEC)
Program (Call / Save)
Setting Speed
Touch once : RPM / Touch twice : RCF
Start/Stop Lid Open
After Operation
AO-15/10-12 6 x 15 mL or 12 x 10 mL / Max. 4k
30 cm
30 cm
30 cm
Fixed-angle Rotors
140VA
220V 50/60Hz
HI-QG-T04(Rev.0)
Quick Guide T04
Cat. No. : T04
HI-QG-T04(E)(Rev.0)
Order & Inquiry l +82-2-3472-0727 l info@ihanil.com l www.ihanil.com
Service l +82-2-3452-8966 l [email protected]
Before Operation
Check the rotor is rmly tightened onto
the motor shaft.
Check the Rotor Locking
After relocating the device or loading the rotor,
balance them by using a leveler. If necessary,
level the device by adjusting the‘Leveling
foot’on the bottom of the device.
Balancing the Centrifuge and Rotor
Cautions For Use
Check the rotor, buckets and tubes are
free of scratch and crack before operation.
Check the Accessories for Abnormalities
Load tubes symmetrically into the
rotor with identical amount.
Load Tubes Symmetrically
Rotor
Electrical Safety
Switch o the device after
use. Unplug the power plug
before cleaning or unused for
a long period of time.
Check the wall outlet
is earth grounded,
surge-protected andcan
supply enough power.
Switch O the DeviceGrounded Outlet
Check the Line Voltage
Maintenance
Connect the device to voltage
sources which correspond to
the electrical requirements on
the label attached to the device.
If the device door cannot be opened, you can activate
the emergency open manually. 1. Wait for rotor to stop
before activating the emergency open. 2. Insert the pin
into the emergency open hole and push it until the door
is opened.
Emergency Lid Open
Keep a safety clearance of 30 cm around the
centrifuge during operation.
Keep a Safety Clearance
Wipe up the moisture in the chamber
with a dry cloth after use. Keep the lid
open when not in use.
Clean the chamber and rotor by wiping
with a cloth soaked in mild detergent and
dry completely.
Keep the Chamber DryCleaning

Other manuals for T04

1

Other Hanil Laboratory Equipment manuals

Hanil T05R User manual

Hanil

Hanil T05R User manual

Hanil FLETA 4 User manual

Hanil

Hanil FLETA 4 User manual

Hanil T04 User manual

Hanil

Hanil T04 User manual

Hanil M15R User manual

Hanil

Hanil M15R User manual

Hanil Fleta 5 User manual

Hanil

Hanil Fleta 5 User manual

Hanil M 13 User manual

Hanil

Hanil M 13 User manual

Hanil Smart 13 User manual

Hanil

Hanil Smart 13 User manual

Hanil M15S User manual

Hanil

Hanil M15S User manual

Hanil Component wR User manual

Hanil

Hanil Component wR User manual

Hanil HyperVAC HVC-2124 User manual

Hanil

Hanil HyperVAC HVC-2124 User manual

Hanil FLETA 4 User manual

Hanil

Hanil FLETA 4 User manual

Hanil Supra R17 User manual

Hanil

Hanil Supra R17 User manual

Hanil Smart R17 User manual

Hanil

Hanil Smart R17 User manual

Hanil T05R User manual

Hanil

Hanil T05R User manual

Hanil FLETA 40P User manual

Hanil

Hanil FLETA 40P User manual

Hanil Smart 15 Plus User manual

Hanil

Hanil Smart 15 Plus User manual

Hanil T04B User manual

Hanil

Hanil T04B User manual

Hanil Smart 15 Plus User manual

Hanil

Hanil Smart 15 Plus User manual

Hanil Fleta5 User manual

Hanil

Hanil Fleta5 User manual

Hanil Ultra 5.0 User manual

Hanil

Hanil Ultra 5.0 User manual

Hanil Cellspin II User manual

Hanil

Hanil Cellspin II User manual

Hanil J1250 User manual

Hanil

Hanil J1250 User manual

Hanil Fleta 5 User manual

Hanil

Hanil Fleta 5 User manual

Hanil Supra R30 User manual

Hanil

Hanil Supra R30 User manual

Popular Laboratory Equipment manuals by other brands

Radleys Carousel 6 Plus instructions

Radleys

Radleys Carousel 6 Plus instructions

Hemotherm 400MR Operation & technical manual

Hemotherm

Hemotherm 400MR Operation & technical manual

mrclab DVO Series Operation manual

mrclab

mrclab DVO Series Operation manual

CoolLED pE-800 quick start guide

CoolLED

CoolLED pE-800 quick start guide

Luminex Guava easyCyte Maintenance Guide

Luminex

Luminex Guava easyCyte Maintenance Guide

IKA A10 basic operating instructions

IKA

IKA A10 basic operating instructions

Belden HIRSCHMANN RPI-P1-4PoE installation manual

Belden

Belden HIRSCHMANN RPI-P1-4PoE installation manual

Koehler K1223 Series Operation and instruction manual

Koehler

Koehler K1223 Series Operation and instruction manual

Globe Scientific GCM-12 quick start guide

Globe Scientific

Globe Scientific GCM-12 quick start guide

Getinge 86 SERIES Technical manual

Getinge

Getinge 86 SERIES Technical manual

CORNING Everon 6000 user manual

CORNING

CORNING Everon 6000 user manual

Biocomp GRADIENT MASTER 108 operating manual

Biocomp

Biocomp GRADIENT MASTER 108 operating manual

Cole Parmer Stuart SB3/1 instruction manual

Cole Parmer

Cole Parmer Stuart SB3/1 instruction manual

BEVS 2501/2A user manual

BEVS

BEVS 2501/2A user manual

Qiagen DML 3000 user manual

Qiagen

Qiagen DML 3000 user manual

Queensgate NANOSCAN OP400 Quick start instructions

Queensgate

Queensgate NANOSCAN OP400 Quick start instructions

Parr Instrument 4560 Operating instructions manual

Parr Instrument

Parr Instrument 4560 Operating instructions manual

Integra DOSE IT operating instructions

Integra

Integra DOSE IT operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.