Honeywell SC100 User manual

Honeywell SC100 Seismic Vibration Detector
Installation Guide
1. General Information
SC100 Seismic Vibration Detector is a universal seismic or structural vibration detector designed to detect selected vibrations
from burglary or intrusion attempt to high value storage units, such as Vaults, Doors, ATMs, Safes and other solid structures.
The detector consists of a sensor to convert mechanical vibrations to electrical signals, a signal conditioning block, signal
analysis and alarm criteria blocks, output alarm circuits, tamper protection, and a switching block for selecting detector
settings, all in a miniature metal housing.
This Installation Guide provides general information about the mounting and configuring of SC100 Seismic Vibration Detector.
For more details, such as planning detector locations, please refer to “SC100 Seismic Vibration Detector Planning and
Installation Guide”.
2. Applications
SC100 Seismic Vibration Detector is designed to detect any known attack tool on:
Vault Doors
ATMs
Night Deposit Safes
Strong Room Vaults
Modular Vaults
Free Standing Safes
Hatches
Gates
Chests
Other objects with a solid structure
2.1 Application Settings
Sensitivity
Settings Material Detection
Radius Applications Noise Level
Ghigh Concrete 5.0m
Strong Room Vaults, Vault Doors, Modular Vaults,
Safes and ATMs (advised for grade 4 to 6) Insignificant noise level
Concrete 2.5m
Gnormal Steel 4.0m
Strong Room Vaults, Vault Doors, Modular Vaults,
Safes and ATMs Moderate noise level
Concrete 1.5m
Glow Steel 2.0m
Safes, Night Deposit Safes, ATMs and Chests Considerable noise level
Gnoisy Steel 1.5m
Safes, Night Deposit Safes, ATMs and chests with
excessive noise (internal or external) Heavy noise level
Notes:
1. Sensitivity settings (Ghigh, Gnormal, Glow, Gnoisy) are defined in “4.2.1 DIP Switch Settings”.
2. The parameters in the table above are only for reference, and they may vary according to the quality of the material.
3. The detection range will be reduced if cracks and joints exist in the material.
3. Mounting the Detector
SC100 Seismic Vibration Detector can be mounted on any solid surface, of which the most common surfaces are: Steel,
Stainless Steel, Hardened Steel and Concrete.
3.1 Opening the Detector
Before mounting the detector, separate the detector cover from the detector base first (by loosing the top screw, see Figure 1).
Figure 1 Open the detector
Detector Cover Detector Base
Figure 2 Drill Plan
Note Please r emove the d rill
:
plan after mounting holes
havebe en drilled
3.2 Mounting on Steel
When mounting the detector on a flat and smooth steel surface, both Drill Plan (see Figure 2) and Detector Base can be used
to mark the mounting holes.
1. Remove and clean paint from the mounting area.
2. Attach the detector base or drill plan on the mounting area, then mark the outline and center punch the detector
mounting holes A, B and Test Transmitter SC113 mounting hole C.
A
B
Notes:
Detector base cannot be used to mark Test
Transmitter SC113 mounting hole C.
Skip marking hole C if Test Transmitter
SC113 is not used.
C
A
B
3. Drill the detector mounting holes A, B (Ø 3.3mm and
minimum 8 mm deep), and then thread the two holes
with a M4 Tap (6mm at least).
4. Drill the Test Transmitter SC113 mounting hole C (Ø
3.3mm and minimum 8 mm deep), and then thread
the hole with a M4 Tap (6mm at least).
5. Remove the dill plan and all of the burrs.
Notes:
Cool the tools with oil while drilling and threading.
Skip step 4 if Test Transmitter SC113 is not used.
6. Attach Test Transmitter SC113 on the mounting area (at
C) and then use the M4×8mm screw to fix it.
Note: Skip this step if Test Transmitter SC113 is not used.
C
7. Attach the detector base on the steel surface and
then use the two M4×8mm screws provided to fix it.
8. Wire and configure the detector (see “4. Wirings and
Settings”), and then use the top screw to fix the detector
cover properly.
24-hour surveillance of vaults, doors, safes, ATMs and other high value
storage units
Flat frequency response sensor for genuine signal analysis
DIP switch sensitivity settings
Noise sensitivity settings using built-in diagnostic tool
Integrated EOL resistors
High detection capability
Low current consumption
Standard drill sheet protection
Miniature metal housing – easy to fit in restricted spaces
3.3 Mounting on Stainless Steel or Hardened Steel
When mounting on stainless steel or hardened steel, Mounting Plate SC110 (UPSIDE DOWN, see Figure 4) must be used
and should be welded on the mounting surface first.
Figure 3 Mounting Plate SC110
UPSIDE
F
G
C
D
E
A
B
This orientation is used for mounting
on concrete.
A, B– Detector SC100 mounting hole
C, D, – Test Transmitter SC113 locating hole
E– Mounting Plate SC110 mounting hole
F, G– Welding Slots
Figure 4 Mounting Plate SC110
UPSIDE DOWN
FG
C
D
E
A
B
This orientation is used for mounting on
stainless steel or hardened steel.
1. Remove paint from the mounting area
(especially welding area).
2. Attach
Mounting Plate SC110 on the mounting
area, and then mark the outline.
3. Fix
Mounting Plate SC110 into the outline marked and ensure it
cannot move, and then along the INSIDE of the welding slots
weld Mounting Plate SC110 on the mounting surface.
Note: The welding must be done along the INSIDE of the welding
slots, otherwise Mounting Plate SC110 can be deformed.
4. Tap off slag and remove weld spatter and make sure the whole mounting surface is still flat.
5. Attach Test Transmitter SC113 on Mounting Plate SC110 (at C) and then use the M4×8mm screw to fix it.
Note: Skip this step if Test Transmitter SC113 is not used.
C
6. Attach the detector base on Mounting Plate
SC110 and then use the two M4×8mm screws
provided to fix it.
7. Wire and configure the detector (see “4. Wirings and
Settings”), and then use the top screw to fix the detector cover
properly.
3.4 Mounting on Concrete
When mounting on concrete, Mounting Plate SC110 (UPSIDE, see Figure3) must be used.
Note: Mounting directly on a bare or plastered concrete surface may result in low detection sensitivity and cause damage to
the detector.
1. Attach
Mounting Plate SC110 on the mounting area and
then mark the outline and center hole E.
2. Drill the center hole E of Ø 10mm and minimum 65mm
deep, and then remove all drill residuals and plaster.
E
3. Insert M6 anchor into hole E and make sure the end
of the anchor can reach but not protrude the concrete
surface.
Note: Use a longer M6 anchor or a distance sleeve
between Mounting Plate SC110 and the anchor if the M6
anchor cannot reach the solid concrete.
4. Attach
Mounting Plate SC110 into the outline marked,
and then through the center hole insert M6×50mm
screw into M6 anchor in the wall.
5. Tighten M6×50mm screw but do not fix Mounting
Plate SC110 on the concrete surface, and make sure
Mounting Plate SC110 does not expand either.
Note: Mounting Plate SC110 can be rotated here.
Note: Skip step 6 to step 11 if Test Transmitter SC113 is not used.
6. Rotate clockwise 180˚and mark hole C.
7. Rotate
Mounting Plate SC110 anticlockwise until the
marked hole C can be seen through hole D.
Note: Tighten the center screw slightly to stabilize Mounting
Plate SC110 at this step.
8. Through hole D drill a hole of Ø 5.5 mm and minimum
25mm deep and then remove all residuals.
180
°
Clockwise
CD
D
D
C
C
Anticlockwise
9. Release and turn Mounting Plate SC110 to the original
orientation (see the figure below).
10. Insert M4 anchor into the drilled hole and make sure
the end of the anchor cannot protrude the concrete
surface.
11. Attach Test Transmitter SC113 on M4 anchor, and then
use M4×14mm screw to fix it permanently.
12. Tighten M6×50mm screw (and knock on the screw head with a hammer when needed) until Mounting Plate SC110 is
fixed on the concrete surface and cannot be rotated.
Test Transmitter SC113
mounting hole C
Detector mounting hole A
Note: The top screw is only
used to fix the cover, so do
not tighten it too much
when mounting the detector
Note: The drill plan should be
removed after all of the mounting
holes have been drilled.
Detector mounting hole B
All manuals and user guides at all-guides.com
all-guides.com
4.2.4 J1 Remote Test Settings
13. Attach the detector base on Mounting Plate SC110 and
then use the two M4×8mm screws provided to fix it.
14. Wire and configure the detector (see “4. Wirings and
Settings”), and then use the top screw to fix the
detector cover properly.
Position Function Method Result
1 No test Connect jumper to J1 pin 1 only.
1-2 Electronics test
Connect jumper to J1 pin 1 and 2;
Apply 0 volt to terminal 10 on the terminal
block (see Figure 6) to start the test.
A successful remote test will be
acknowledged by an alarm from
the detector within 1 second.
2-3
Complete test
including mounting
check
Connect Test Transmitter SC113 to J1 (black
cable to pin 2 and red cable to pin 3);
Apply 0 volt to terminal 10 on the terminal
block (see Figure 6) to start the test.
A successful remote test
including mounting check will be
acknowledged by an alarm from
the detector within 1 second.
4. Wirings and Settings
Wirings and settings are configured on detector base. All function modules on the detector base are shown as below.
Figure 5 Detector Base
* Factory default settings are shown in grey.
J1 5. Maintenance
DIP Switches Noise LED Check the detector mounting and functions regularly (once a year at least).
Tamper Switch
Note: Connect Terminal9 to low level (<0.6VDC), the sensitivity of detector will be reduced to about 1/8 of original level.
J19
EOL Jumpers J20 6. Technical Specifications
Terminal Block
Power Requirements
Supply Voltage 8 ~ 16 VDC, nominal 12 VDC
Current Consumption (quiescent) Typical 3 mA @ 12 VDC
Current Consumption (alarm) Typical 2 mA @ 12 VDC
Voltage Ripple 100Hz, ≤10% of nominal voltage
Step Change Unom +/- 25%
Slow Change of Supply Voltage Unom +/- 25%
Warm-up Time < 5 sec
Sensitivity
Adjustable Sensitivity 4 levels by DIP Switches
Reduced Sensitivity (Maintenance, Service) Input Active low (terminal 9) ≤0.6 VDC
Detection Radius (Thermal Tools) on Concrete K350 5 m
Detection Radius (Thermal Tools) on Steel 5 m
Alarm Outputs
Solid State Relay SPDT (Change Over) 30 VDC / 100 mA / typical Ri=25 Ω
Transistor Open Collector Active low during alarm / Ri=1.38 kΩ
Alarm Hold Time Approx. 2.5 sec
Sabotage Protection
Pry-off and Cover Switch 30 VDC / 100 mA
Low Supply Voltage Alarm * < 6.5 VDC
Temperature Alarm * +85°C ± 5°C
Internal Functional Alarm* Stainless steel drill shield
* Sabotage and fault functions will cause the alarm relay to drop.
Inputs
Remote test of detector mounting and detector function or
Remote test of detector electronics only. Active low ≤0.6 VDC, test duration < 1 sec
Reduced Sensitivity (maintenance, service) Input Active low ≤0.6 VDC, duration = as long as active low
Sensitivity reduction to 12.5 %
Installation Tool
A noise and alarm indicator is incorporated to support sensitivity setting.
Environmental Conditions
Maximum Humidity 95% RH (non-condensing)
Operation Temperature -40°C ~ +70°C
Storage Temperature -50°C ~ +70°C
Environmental Class (VdS) III
Housing Protection Category IP43 IK04
Housing
Dimensions (H x W x D) 80 mm x 60 mm x 21 mm
Chassis and Cover Die-cast metal
Color RAL7035 (light grey)
Weight 0.228kg
4.1 Wirings
4.1.1 Terminal Block Wiring
The wirings should be connected to the terminal block first, and then should be connected to the panel.
Figure 6 Terminal Block Wiring
Note: The open collector alarm output
(terminal 8) will be active low during alarm.
4.1.2 Panel Wiring
According to the different terminal block wirings, there are two ways to connect the detector to the panel.
Alarm and tamper configured to one loop Alarm and tamper configured to two loops
RTI RSI S/OC T2 T1 C NC V+NO 0V
Z1
COM
Tamper
RT
Alarm
J20
RA
Connected to a zone configured as Dual-End-of-Line
RTI RSI S/OC T2 T1 C NC V+NO 0V
Ta m p e r
RT
Alarm
J20
Z1 COM Z2
Connected to a zone configured as Single-End-of-Line
Detector
Detector Note: When this wiring
diagram is used, RT still
can be used for tamper
loop, but the jumper on
RA needs be removed
and the external EOL
resistor has to be
connected to alarm
loop.
External EOL
Resistor
Panel
Panel
4.2 Settings
4.2.1 DIP Switch Settings
ON
OFF
Sensitivity Settings Application Settings Noise LED
1 2 3 4
Ghigh off off High sensitivity setting off ATMs/ Night deposit safes off Noise indicator OFF
Gnormal on off Normal sensitivity setting on Safes / Vaults on Noise indicator ON
Glow off on Low sensitivity setting
Gnoisy on on Noisy environment sensitivity setting
7. Certifications and Approvals 8. Ordering Information
SC100 Seismic Vibration Detector meets approvals as
below:
NF&A2P Type 3
IMQ Type 3 (Pending)
UL (Pending)
ULC (Pending)
CE
CCC
VdS G 110004 class C
Mounting Plate
Movable Mounting Kit
Keyhole Protection Kit
Test Transmitter
1.8m Armored Cable Kit (8 wires)
External Test Transmitter
Recess Mounting Box
Floor Mounting Box
Spacer for Keyhole Protection Kit
SC110
SC111
SC112
SC113
SC114
SC115
SC116
SC117
SC118
* Factory default settings are shown in grey.
Notes:
1. Any change of DIP switch 3 will cause an alarm.
2. Any change of DIP switch 3 must be followed by a power-off sequence of 5 seconds.
3. The Noise LED will light or flash intensively if the noise level (external or internal) is too high. Reduce the sensitivity with DIP switch
1 and 2 until the Noise LED turns off.
4. When scratching the surface of the protected object lightly, the Noise LED will turn on as a confirmation of detection.
5. In case of alarm, the Noise LED will flash with 5 Hz, appx. 2.5 seconds.
6. Turning off the Noise LED by DIP switch 4 will reduce current consumption.
9. Shipping List
4.2.2 EOL Jumper Settings
Description Quantity
SC100 Seismic Vibration Detector 1
Screw M4x8mm 2
Cable Strap 1
Drill Plan 1
Two-way Jumper Link 1
Installation Guide 1
Jumper Position EOL Value
1-2 1K
2-3 2.2K
4-5 4.7K
TAMPER
(RT)
5-6 5.6K
1-2 1K
2-3 2.2K
4-5 4.7K
ALARM
(RA)
5-6 5.6K
* Factory default settings are shown in grey. Notice for Installation Guide
Pictures in the manual are for reference only. Please see the actual items.
The products will be updated and the information shall not be distributed.
Please read the book before operation and keep it properly for future use.
The manual has been reviewed and the accuracy is guaranteed. If there is any uncertainty or controversy, please refer to the final explanation of
Honeywell. Honeywell does not take any responsibility for any consequences caused by misunderstanding of the manual or improper operations.
Notes:
1. Refer to Control Panel manual for proper EOL selection.
2. For each block, only one EOL value can be set.
3. Other EOL resistor values can be used by removing all jumpers on the EOL jumper field and wire new resistors directly on the
terminal block.
4.2.3 J19/J20 Settings
No Jumper Jumper
J19 Terminal 8 = Not Used Terminal 8 = Alarm O/C Output
J20 Connect SC111/SC112 to the loop Normal Close Honeywell
* Factory default settings are shown in grey. © 2010 Honeywell International Inc.
www.honeywell.com/security
Document 800-04805 Rev. C
All manuals and user guides at all-guides.com

Other manuals for SC100

2

Other Honeywell Security Sensor manuals

Honeywell PEHA LightSpot Mid Range Series Installation and operation manual

Honeywell

Honeywell PEHA LightSpot Mid Range Series Installation and operation manual

Honeywell Miller Scorpion User manual

Honeywell

Honeywell Miller Scorpion User manual

Honeywell DUAL TEC DT8050A User manual

Honeywell

Honeywell DUAL TEC DT8050A User manual

Honeywell ToxiPro CO User manual

Honeywell

Honeywell ToxiPro CO User manual

Honeywell BW Solo User manual

Honeywell

Honeywell BW Solo User manual

Honeywell GasAlert Max XT II User manual

Honeywell

Honeywell GasAlert Max XT II User manual

Honeywell FG8M User manual

Honeywell

Honeywell FG8M User manual

Honeywell SS2-A User manual

Honeywell

Honeywell SS2-A User manual

Honeywell IntelliSense FG-1625RFM User manual

Honeywell

Honeywell IntelliSense FG-1625RFM User manual

Honeywell Friedland FGGA08 Series User manual

Honeywell

Honeywell Friedland FGGA08 Series User manual

Honeywell Ex-Or MLS2500CDR Installation and operation manual

Honeywell

Honeywell Ex-Or MLS2500CDR Installation and operation manual

Honeywell Eclipse Instruction Manual

Honeywell

Honeywell Eclipse Instruction Manual

Honeywell Miller Revolution Harness User manual

Honeywell

Honeywell Miller Revolution Harness User manual

Honeywell IRV800M User manual

Honeywell

Honeywell IRV800M User manual

Honeywell PEHA D-LS1000R User manual

Honeywell

Honeywell PEHA D-LS1000R User manual

Honeywell FIRE-LITE ALARMS W-SD355 User manual

Honeywell

Honeywell FIRE-LITE ALARMS W-SD355 User manual

Honeywell 1031030 User manual

Honeywell

Honeywell 1031030 User manual

Honeywell XT Series User manual

Honeywell

Honeywell XT Series User manual

Honeywell 5800FLOOD User manual

Honeywell

Honeywell 5800FLOOD User manual

Honeywell C7061A1020 User manual

Honeywell

Honeywell C7061A1020 User manual

Honeywell VERSAFLOW MAG 4000 User manual

Honeywell

Honeywell VERSAFLOW MAG 4000 User manual

Honeywell Miller MightyLite Series User manual

Honeywell

Honeywell Miller MightyLite Series User manual

Honeywell CLLRF2OCR2BP User manual

Honeywell

Honeywell CLLRF2OCR2BP User manual

Honeywell Farenhyt Series User manual

Honeywell

Honeywell Farenhyt Series User manual

Popular Security Sensor manuals by other brands

GEV FlammEX FMW 3552 manual

GEV

GEV FlammEX FMW 3552 manual

Aqara DW-S03D user manual

Aqara

Aqara DW-S03D user manual

kobi LX20 quick start guide

kobi

kobi LX20 quick start guide

tau DOORRADMB instruction manual

tau

tau DOORRADMB instruction manual

THORLABS PDA8A2 Abbreviated operation manual

THORLABS

THORLABS PDA8A2 Abbreviated operation manual

Kolibri Bishop user manual

Kolibri

Kolibri Bishop user manual

GE PrecisionLine RCR-90 installation instructions

GE

GE PrecisionLine RCR-90 installation instructions

Berbel AutoRun 2.0 installation instructions

Berbel

Berbel AutoRun 2.0 installation instructions

Texora ULTRA-WIND Instructions for use

Texora

Texora ULTRA-WIND Instructions for use

Megger Surgeflex 15 instruction manual

Megger

Megger Surgeflex 15 instruction manual

Volth S-AC200 instruction manual

Volth

Volth S-AC200 instruction manual

klemko Lumiko PLF-IB-PIR/1U instructions

klemko

klemko Lumiko PLF-IB-PIR/1U instructions

elsner elektronik Sewi KNX L-Pr Installation and adjustment

elsner elektronik

elsner elektronik Sewi KNX L-Pr Installation and adjustment

SEDEA no-531440-2211 installation instructions

SEDEA

SEDEA no-531440-2211 installation instructions

Clarke CDM65 Operating & maintenance instructions

Clarke

Clarke CDM65 Operating & maintenance instructions

Ritter FR-74 Assembly and instruction manual

Ritter

Ritter FR-74 Assembly and instruction manual

Elko inelsAir AirSF-100L manual

Elko

Elko inelsAir AirSF-100L manual

ESP Safety IPES Series Quick installation guide

ESP Safety

ESP Safety IPES Series Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.