17
3The Alarm.com module is trying to register on the cellular
network. If it persists for more than a few minutes, the
module is having problems registering. Check L4 for signal
level. If signal level is lower than 2 bars, change the panel’s
location or use a remote antenna option.
4The Alarm.com module is registered on the cellular network
but could not connect with Alarm.com. Contact Alarm.com
Technical Support.
5The radio on the module is not working correctly. If this persists
for more than a few minutes the module may need to be
replaced. This error is extremely rare, so please verify that the
6This indicates an error only if it persists for more than a
minute. Otherwise, it’s an indication that the module is
resolving an unusual condition regarding communication
with the cellular network.
7The SEM is unable to access panel programming.
Check panel wiring and Installer Code.
8If this error persists, the account may have been set up
incorrectly. Check that the serial number being used matches
the serial number used to create the account. If the serial
numbers are the same, contact Technical Support.
when the Alarm.com module is in Idle mode or four seconds in PowerSave
mode. See Alarm.com Module States (modes) for an explanation of the
three modes.
when the SEM is being used to add or remove Z-Wave devices.
in Idle mode, and with every communication with Alarm.com in Connected
The number of bars may not correspond to the number of bars shown
on your cell phone. A level of 5 bars is obtained only in the strongest
or every 30 seconds if it is fairly stable.
as the provisioning process is complete.
• The Alarm.com module is in PowerSave mode
• The Alarm.com module just powered up
• There is no cellular coverage in the area
Alarm.com recommends a steady signal level of two
or higher for proper operation of the SEM.