3 / 4
RFGB-20 RFGB-40 RFGB-220 RFGB-240
Technical parameters
More detailed information can be found in the iNELS RF Control Installation Manual:
https://www.elkoep.com/catalogs-and-brochures
ELKO EP, sro hereby declares that the type of radio equipment RFGB-20, RFGB-40,
RFGB-220, RFGB-240 is in accordance with Directives 2014/53 / EU, 2011/65 / EU,
2015/863 / EU and 2014 / 35 / EU. The full text of the EU Declaration of Conformity is
available on the following websites:
www.elkoep.com/glass-touch-controller---2-buttons-white-sharp
www.elkoep.com/glass-touch-controller---2-buttons-black-sharp
www.elkoep.com/glass-touch-controller---4-buttons-white-sharp
www.elkoep.com/glass-touch-controller---4-buttons-black-sharp
www.elkoep.com/glass-touch-controller---2-buttons-white-round--rfgb-220w
www.elkoep.com/glass-touch-controller---2-buttons-black-round-rfgb-220b
www.elkoep.com/glass-touch-controller---4-buttons-white-round-rfgb-240w
www.elkoep.com/glass-touch-controller---4-buttons-black-round-rfgb-240b
When handling a device unboxed it is important to avoid contact
with liquids. Never place the device on the conductive pads or
objects, avoid unnecessary contact with the components of the
device.
Safe handling
Attention:
When you instal iNELS RF Control system, you have
to keep minimal distance 1 cm between each units.
Between the individual commands must be an
interval of at least 1s.
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate
professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on
transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat
this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting
and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized - life
threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors.
The must not be installed into metal switchboards and into plastic switchboards with metal door - transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys
etc. - radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.
Warning
Power voltage:
Battery life:
Transmission indication:
Number of capacitive buttons:
Communication Protocal:
Frequence:
Signal transmission method:
Range:
Other data
Operating Temprature:
Working Position:
Mounting:
Protection:
Pollution degree:
Dimension:
Weight:
Related standards:
2x 3 V battery CR 2032
about 2 years depending on the frequency of use
Red LED
2 4 2 4
RFIO
866–922 MHz
one-way addressed message
in the open up to 200 m
-10 ... +50 °C
any
adhesive, screw
IP20
2
94 x 94 x 8 mm 100 x 100 x 8 mm
122 g 122 g 122 g 122 g
EN 60669, EN 300 220, EN 301 489 RTTE Directive,NV No. 426/2000 Coll. (Directive 1999 / EC)