4 2. OPERATING THE JA-10 SYSTEM
Users and Their Access Rights
CODE AUTHORIZATION TYPE DESCRIPTION
ARC code This code has the highest level of authorization to configure the system’s behaviour and is exclusively
allowed to perform the system unblock after a triggered alarm. It can enter Service mode, access all
tabs with options including ARC communication to which it can deny access to a Service technician
(Service code). As long as the “Administrator-restricted Service/ARC right” parameter remains
unchecked, the ARC code can control all sections and PG outputs used in the system. This code
enables to add more Administrators and other users with a lower level of authorization, assign them
with codes or RFID tags. It also has a permission to erase alarm and tamper alarm memory.
The number of ARC codes is limited only by remaining capacity of the control panel.
Service code
(Service)
It can enter Service mode and configure the system’s behaviour. It has access to all tabs with
options including ARC communication unless the access is limited by a superior ARC technician.
As long as the “Administrator-restricted Service/ARC right” parameter remains unchecked, the
Service code can control all sections and PG outputs used in the system. It can create a user with
ARC permission, other Service technicians, Administrators and other users with a lower level of
authorization and assign them with access codes or RFID tags. It also has a permission to erase
alarm and tamper alarm memory. The number of Service codes is limited only by remaining capacity
of the control panel. By the factory defaults, the code is 1010 and it cannot be erased.
Administrator
(Main)
This code has always full access to all sections and is authorized to control all PG outputs.
The Administrator can create other Administrator and other codes with a lower level of authorization,
assign them with access to sections, PG outputs, access codes or RFID tags. It has permission to
erase the alarm and tamper memory. There can be only one main Administrator code which cannot be
erased. When “Administrator-restricted Service/ARC right” is enabled, the administrator code must be
authorized as to confirm access. By the factory defaults, the code is 1234.
Administrator
(Other)
This type of Administrator code has access to sections selected by the main Administrator to
which the other Administrator can add new users with the same or lower level of authorization
in order to control sections and PG outputs, assign them with access codes or RFID tags. It has
permission to erase the alarm and tamper memory in assigned sections. When “Administrator-
restricted Service/ARC rights” is enabled, the administrator code must be authorized as to
confirm access. The number of Administrator codes (other) is limited only by remaining capacity
of the control panel. There is no code set by the factory defaults.
User This code has access to sections and PG control rights assigned by an Administrator. Users
can add/delete their RFID tags and change their telephone numbers. It has a permission to erase
the alarm memory in assigned sections. Selected user may have time-limited access to their
sections. The number of User codes is limited only by remaining capacity of the control panel.
There is no code set by the factory defaults.
Set This code is allowed only to set a designated section and is allowed to control (ON/OFF) PG
outputs which require authorization. Users with this level of authorization are not allowed to change
their code and are not allowed to erase the alarm memory. The number of Set codes is limited only
by remaining capacity of the control panel. There is no code set by the factory defaults.
PG only Allows the user to control programmable outputs with authorization only. This applies to both
switching on and off. Users with this level of authorization are not allowed to change their codes.
The number of PG only codes is limited only by remaining capacity of the control panel. There is
no code set by the factory defaults.
Panic This code is allowed only to trigger Panic alarm. A user of this code is not allowed to change it
or erase the alarm memory. The number of Panic codes is limited only by remaining capacity of
the control panel. There is no code set by the factory defaults.
Guard Code This is a code for a security agency. This level of authorization allows to set the whole system.
However the guard code can unset the system only during alarm or after it has expired as long as
the alarm memory is still active. A user of this code is not allowed to change it or erase the alarm
memory. The number of Guard codes is limited only by remaining capacity of the control panel.
There is no code set by the factory defaults.
Unblocking code This code is designated only to unblock the system after System blocking by alarm. A user of
this code is not allowed to control the control panel, change this code or erase the alarm memory.
The number of Unblocking codes is limited only by remaining capacity of the control panel. There
is no code set by the factory defaults.