JA-151A Wireless external siren
The JA-151A is a component of the JABLOTRON 100 system.
It is used for system alarm indication outside a building and as
a pre-sensing tamper detector. It can also be used for
supplementary acoustic signalling (PG activation, arming, chirps).
The siren is equipped with a backup battery which powers the siren
when the main power is disconnected. The JA-151A includes only
the base with the JA-151A BASE PCB and always has to be
completed with the cover from the JA-1X1A-C-xx series. The siren
should be installed by a trained technician with a valid certificate
issued by an authorized distributor.
For combinations of colour and cover material see the following table:
Cover type Colour and cover
material
Strobe colour
JA-1X1A-C-GR Grey plastic
Red
JA-1X1A-C-ST Stainless steel sheet
JA-1X1A-C-WH White plastic
JA-1X1A-C-GR-B Grey plastic
Blue
JA-1X1-C-ST-B Stainless steel sheet
JA-1X1A-C-WH-B White plastic
Installation
The siren should be installed on a vertical wall, with the flasher
facing downwards. Avoid installing the siren near the gutters and on
other places where there is a danger of ice accumulation.
Fig: 1 – hole for installing; 2 – piezo sounders; 3 – NiCd battery with reusable
battery strap; 4 – hole for cable; 5 – 12V DC power cable; 6 – PCB; 7 – spirit
level; 8 – hole for installation with tamper detection; 9 – front cover screw;
10 – string with clip connecting the front cover for easy installation
1. Push the power cable (5) through the hole (4) in the bottom part
and secure it using the plastic tabs.
2. Attach the siren onto a suitable place using 2 screws through the
holes (1) and (8). The spirit level can be used for easy
installation (7).
3. Connect the backup battery to the connector (13).
4. Connect the mains power cable to the terminals (11).
5. Proceed according to the control panel installation manual.
Basic procedure:
a. There must be a JA-110R radio module installed in in the
control panel.
b. When the power supply is connected, the yellow LED (14)
starts flashing to indicate that the siren has not been
enrolled into the system.
c. Go to the F-Link software, select the required position in the
Devices tab and launch the enrolment mode by clicking on
the Enroll option.
d. Press the button marked LEARN (15) – the siren is thus
enrolled and the yellow LED indicator goes off.
6. Put back the siren cover and attach it using the screw (9).
Fig 2: 11- 12V DC power terminals; 12 – piezo siren connection (attention: high
voltage); 13 – backup battery connection; 14 – yellow fault indicator;
15 – LEARN (enrolment) button; 16 – external antenna connection;
17 – external antenna jumper; 18 – high intensity red LED flashers;
19 – production code
Internal settings of the siren
The siren properties can be set in the Devices window of the F-link
software. When at the siren position, use the Internal settings option
to open a dialog window where you can set: (default settings are
marked *):
Sections: to set for which sections the siren should indicate an
alarm, as well as setting the chirps. The default setting is
indication for all sections.
Reaction: defines whether the siren should indicate EW*
(external warning) or IW (internal warning); Alarm indication can also
be disabled completely (other functions remain enabled).
LED indication: Red* / Blue. According to the siren cover you
can choose the colour of the LED indicators.
Siren sound: interrupted*, uninterrupted.
Alarm indication length: 1, 2, 3*, 4, 5 minutes.
Chirps during section control YES / NO* if enabled, the siren
chirps once upon setting and twice upon unsetting and three times
upon unsetting after an alarm. The signalling only works for the
preset sections.
Siren flashing options: During alarms */ (flashes) 30 minutes
after an alarm. Extended flashing can be terminated by new system
setting or cancellation of alarm indication in the system (with a
keypad).
Flashes every 60 seconds: YES / NO* optional indication of
siren functioning.
PG output activity indication
The siren can indicate the activity of selected PG outputs with its
chirps.
Chirp 1 – slow chirping - 1 per second (for the whole period when
the PG is active)
Chirp 2 – rapid chirping - 2 per second (for the whole period when
the PG is active)
Chirp 3 - 1 chirp when the PG is activated, 2 chirps when the PG
is deactivated
Chirp 4 – a long 20 sec chirp when the PG is activated
Sound priorities
The siren sound has the highest priority, the control chirps have a
lower priority and the PG output activity indication has the lowest
priority (PG1 has a higher priority than PG2 etc). A chirp with a
higher priority always terminates a chirp with a lower priority.
Note: Acoustic power depends on battery charge level.
External antenna use
To improve the communication quality between the control panel
and the outdoor siren you can connect an external antenna (AN-80,
AN-81). Plug the antenna into the connector (16) on the PCB. When
an antenna is plugged in, disconnect the jumper (17).
JA-151A Wireless external siren 1 / 2 MMG51104
JA-151A Wireless external siren
Technical specifications
Power 12 V DC
230V AC/12 V DC optional adaptor (DE-06-12)
Communication band 868.1 MHz, JABLOTRON protocol
Communication range approx. 300 m (open area)
Backup battery / lifetime NiCd pack 4.8 V / 1800 mAh
approx. 3 years
- minimum loaded voltage 4.0 V
(replace the battery when voltage drops down this value)
- maximum unloaded voltage 6.0 V
Piezo electric siren 110 dB/m (with fully charged battery)
Dimensions 200 x 300 x 70 mm
Classification grade 2
According to EN 50131-1, EN 50131-4, EN 50131-5-3
Environmental class IV general outdoor -25 to +60°C
Security grade IP41
Also complies with ETSI EN 300220, EN 50130-4,
EN 55022, EN 60950-1
Can be operated to ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the JA-151A-is in
compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC and 2011/65/EU. The original of
the conformity assessment can be found at www.jablotron.com -
Technical Support section
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use. For more detailed information
visit www.jablotron.com.
JA-151A Wireless external siren 2 / 2 MMG51104

Other jablotron Security System manuals

jablotron Azor User manual

jablotron

jablotron Azor User manual

jablotron OS-310 FORTE User manual

jablotron

jablotron OS-310 FORTE User manual

jablotron MAESTRO JA-65 User manual

jablotron

jablotron MAESTRO JA-65 User manual

jablotron JA-60 "Comfort" User manual

jablotron

jablotron JA-60 "Comfort" User manual

jablotron 100+ User manual

jablotron

jablotron 100+ User manual

jablotron JA60K User manual

jablotron

jablotron JA60K User manual

jablotron JA-63A User manual

jablotron

jablotron JA-63A User manual

jablotron JA-114E User manual

jablotron

jablotron JA-114E User manual

jablotron JA-16A RB User manual

jablotron

jablotron JA-16A RB User manual

jablotron OS-360 User manual

jablotron

jablotron OS-360 User manual

jablotron JK-82UK Oasis User manual

jablotron

jablotron JK-82UK Oasis User manual

jablotron UC-261 User manual

jablotron

jablotron UC-261 User manual

jablotron JA-162A-US User manual

jablotron

jablotron JA-162A-US User manual

jablotron JA-10 Series User manual

jablotron

jablotron JA-10 Series User manual

jablotron GT 970 User manual

jablotron

jablotron GT 970 User manual

jablotron Oasis RC-87 User manual

jablotron

jablotron Oasis RC-87 User manual

jablotron JA-60IR User manual

jablotron

jablotron JA-60IR User manual

jablotron JA-163A Series User manual

jablotron

jablotron JA-163A Series User manual

jablotron JA-151IR User manual

jablotron

jablotron JA-151IR User manual

jablotron Oasis User manual

jablotron

jablotron Oasis User manual

jablotron OS-360A User manual

jablotron

jablotron OS-360A User manual

jablotron MAESTRO JA-65 User manual

jablotron

jablotron MAESTRO JA-65 User manual

jablotron Oasis JA-80 User manual

jablotron

jablotron Oasis JA-80 User manual

jablotron OASiS 8 Series User manual

jablotron

jablotron OASiS 8 Series User manual

Popular Security System manuals by other brands

Bosch Divar Operation manual

Bosch

Bosch Divar Operation manual

Snap-On BK8000 user manual

Snap-On

Snap-On BK8000 user manual

Aritech CS-175 Series installation guide

Aritech

Aritech CS-175 Series installation guide

Vimar BY-ALARM PLUS user manual

Vimar

Vimar BY-ALARM PLUS user manual

Lorex SG14S1022P Specifications

Lorex

Lorex SG14S1022P Specifications

ADEMCO N7227V5 installation instructions

ADEMCO

ADEMCO N7227V5 installation instructions

Kompernass FA 110 A1 operating instructions

Kompernass

Kompernass FA 110 A1 operating instructions

ALC AHS613 user guide

ALC

ALC AHS613 user guide

Adesys Octalarm-IP manual

Adesys

Adesys Octalarm-IP manual

stabo multifon security IV user manual

stabo

stabo multifon security IV user manual

Siemens FDM1101-R Series Technical manual

Siemens

Siemens FDM1101-R Series Technical manual

Avidsen 100872 Quick installation guide

Avidsen

Avidsen 100872 Quick installation guide

Aritech DM3000 Series Installation sheet

Aritech

Aritech DM3000 Series Installation sheet

Bosch DIP-3040-00N installation manual

Bosch

Bosch DIP-3040-00N installation manual

Hali-Brite L801AL116 Installation and maintenance manual

Hali-Brite

Hali-Brite L801AL116 Installation and maintenance manual

ATS-TN SkyAngel 911FD user guide

ATS-TN

ATS-TN SkyAngel 911FD user guide

Pisector Motion sensor user manual

Pisector

Pisector Motion sensor user manual

AUTHOR Alarm IGLA operating manual

AUTHOR Alarm

AUTHOR Alarm IGLA operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.