manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LEGRAND
  6. •
  7. Keypad
  8. •
  9. LEGRAND 5 722 52 User manual

LEGRAND 5 722 52 User manual

Factory settings: Master code = 1111 Buzzer active Opening the pushbutton: NO No user code Release control: pulse Release tempo = 5 seconds Access status: protected Keypad not locked if incorrect code entered
Activation of programming mode : Enter the master code twice and confirm with the # key. The keypad switches to programming mode and the red and green indicators flash alternately. Automatic exit from programming mode if no key is depressed for a period of 60 seconds.
Master code : The master code is the entry key for all possible modifications. Only the system administrator may know the master code. The master code consists of 4 to 8 numbers the default master code is «1111». For security reasons, the master code must be changed.
Changing the master code: activate programming mode, press 1 *, enter the new master code (4 to 8 numbers) and confirm with #. A confirmation beep will sound. Quit the programming mode by pressing #.
Example of changing the master code «1111» via «123456»: 1111 1111 # 1 * 123456 # #
Learning of one or several user codes : Activate programming mode and enter the order number for the user code to be created (00 to 99), enter the user code (4 to 8 numbers), confirm with #. A confirmation beep confirms the learning. Restart operations to to teach in a new code or exit programming mode by pressing #.
Example, teach in user code 12548: 1111 1111 # 04 12548 # #
Deleting one or more user codes : Activate programming mode and enter the order number for the user code to be deleted (00 to 99), confirm with #. A confirmation beep confirms deletion of the user code. Restart operations to  to delete another code or exit programming mode by pressing #
Example, deletion of user codes 02 and 12: 1111 1111 # 02 # 12 # #
Deleting all user codes : Activate programming mode, press 5 * 0, confirm with #. A confirmation beep confirms the deletion of all user codes. Quit the programming mode by pressing #.
Example: 1111 1111 # 5 * 0 # #
Controlling the release : Activate programming mode, press 2 *, enter 000 (bi-stable mode 0 <---> 1) or 001 to 255 (pulse mode) for a period ranging between 001 and 255 seconds, confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example, 15 second period: 1111 1111 # 2 * 015 # #
Disabling/enabling the buzzer :  Activate the programming mode, press 4 *, enter 0for disabled or 1for enabled, confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example, disabled: 1111 1111 # 4 * 0 # #
Pushbutton open :  Activate programming mode, press 6 *, enter 0for NO or 1for NC, confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example of NC: 1111 1111 # 6 * 1 # #
Keypad locked following 5 successive entries of the incorrect code :  Activate programming mode, press 7 *, enter 0for a disabled lock or 1to 9for an enabled lock for 1 to 9 minutes, confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing # .
Example of a 5 minute lock: 1111 1111 # 7 * 5 # #
Configuring free access :  Activate programming mode, press 8 *, enter 0for protected access or 1to 98 for free access for 1 to 98 hours or 99 for permanent free access, confirm with #. A confirmation beep confirms the modification. Quit the programming mode by pressing #.
Example of free access for 4 hours: 1111 1111 # 8 * 4 # #
Restore to factory settings except for user codes and master code :  Activate programming mode, press 5 * 2, confirm with #. A confirmation beep confirms the deletion of all user codes. Quit the programming mode by pressing #.
Example: 1111 1111 # 5 * 2 # #
Restore factory settings for all data :  Activate programming mode, press 5 * 1, confirm with #. A confirmation beep confirms the deletion of all user codes. Quit the programming mode by pressing #.
Example: 1111 1111 # 5 * 1 # #
Restore factory settings without master code : Keep pushbutton 1 (BP 1) and pushbutton 2 (BP 2) depressed, release pushbutton 2, wait 10 seconds for the double confirmation beep, then release pushbutton 1
Safety instructions
This product should be installed in compliance with installation rules, preferably by a qualied electrician.
Incorrect installation and use can lead to risk of electric shock or re.
Before carrying out the installation, read the instructions and take account of the product’s specic mounting location.
Do not open up, dismantle, alter or modify the device except where specically required to do so by the instructions.
All Legrand products must be opened and repaired exclusively by personnel trained and approved by Legrand.
Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees.
Use only Legrand brand accessories.
3
456
78
2
1
9
0
#
Self-contained keypad
5 722 52 / 5 727 52
LE01483AC
UΙ max.
1N4007
-
+
1N4007
-
+
~IP
IK
C
TR
IP
IK
~IP
IK
C
TR
~IP
IK
C
TR
~IP
IK
C
TR
~IP
IK
C
TR
~IP
IK
C
TR
12 V
~IP
IK
C
TR
24 V
~IP
IK
C
TR
70 mA
45 mA 12 V 2 A
24 V 2 A
48 V 1,2 A
IP 30
IK 04
- 10° C
+ 55° C
≥ 40 mm 5 U
> 0,90 m
< 1,30 m
100
12 V
~IP
IK
C
TR
24 V
~IP
IK
C
TR
35 mA
20 mA
LED D1 D0 - +C T R
BP1 BP2
(+) 12 / 24 V
(-) 0 V
~
IP
IK
C
TR
LED D1 D0 - +C T R
BP1 BP2
3
2
1
4
8 mm
1N4007
-
+
1N4007
-
+
#
#
#
#
#
#
12 V 2 A
24 V 2 A
48 V 1,2 A
3
456
78
2
1
9
0
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
3
2
1
4
LE01483AC

This manual suits for next models

1

Other LEGRAND Keypad manuals

LEGRAND lyriQ Assembly instructions

LEGRAND

LEGRAND lyriQ Assembly instructions

LEGRAND Radiant AU7010 User manual

LEGRAND

LEGRAND Radiant AU7010 User manual

LEGRAND 5739 46 User manual

LEGRAND

LEGRAND 5739 46 User manual

LEGRAND Mosaic User manual

LEGRAND

LEGRAND Mosaic User manual

LEGRAND AU7010 Series User manual

LEGRAND

LEGRAND AU7010 Series User manual

LEGRAND 5 722 54 User manual

LEGRAND

LEGRAND 5 722 54 User manual

LEGRAND AU5009WH User manual

LEGRAND

LEGRAND AU5009WH User manual

LEGRAND Soliroc 0 778 73 User manual

LEGRAND

LEGRAND Soliroc 0 778 73 User manual

LEGRAND AU7050 User manual

LEGRAND

LEGRAND AU7050 User manual

LEGRAND lyriQ AU5010 Series User manual

LEGRAND

LEGRAND lyriQ AU5010 Series User manual

LEGRAND Vantage RK12E-A Series User manual

LEGRAND

LEGRAND Vantage RK12E-A Series User manual

LEGRAND Vantage Arteor KSS14AR Series User manual

LEGRAND

LEGRAND Vantage Arteor KSS14AR Series User manual

LEGRAND On Q lyriQ User manual

LEGRAND

LEGRAND On Q lyriQ User manual

LEGRAND Soliroc 0 778 70 User manual

LEGRAND

LEGRAND Soliroc 0 778 70 User manual

LEGRAND 4 306 03 User manual

LEGRAND

LEGRAND 4 306 03 User manual

LEGRAND Nuvo NV-P20-LLN User manual

LEGRAND

LEGRAND Nuvo NV-P20-LLN User manual

LEGRAND 0 767 17 User manual

LEGRAND

LEGRAND 0 767 17 User manual

Popular Keypad manuals by other brands

Assa Abloy Alarm Controls KP-400 operating instructions

Assa Abloy

Assa Abloy Alarm Controls KP-400 operating instructions

Response Electronics SAKP E Installation and operating instructions

Response Electronics

Response Electronics SAKP E Installation and operating instructions

Honeywell 6150 - Ademco Fixed - Display Keypad Installation and setup guide

Honeywell

Honeywell 6150 - Ademco Fixed - Display Keypad Installation and setup guide

SILENTRON 5529 manual

SILENTRON

SILENTRON 5529 manual

Jobsite M-4KP datasheet

Jobsite

Jobsite M-4KP datasheet

Arcanus 55 A55 quick start guide

Arcanus 55

Arcanus 55 A55 quick start guide

Simu Hz 2C quick start guide

Simu

Simu Hz 2C quick start guide

Basalte FIBONACCI CRESNET 0272-03 Series installation manual

Basalte

Basalte FIBONACCI CRESNET 0272-03 Series installation manual

DELTA DORE CLLX manual

DELTA DORE

DELTA DORE CLLX manual

Sentryus ACSK-EM user manual

Sentryus

Sentryus ACSK-EM user manual

Scantronic KEY-K01 installation instructions

Scantronic

Scantronic KEY-K01 installation instructions

Simons Voss PEGASYS Teach-in Series quick guide

Simons Voss

Simons Voss PEGASYS Teach-in Series quick guide

HIK VISION DS-PK1-LRT-HWE quick start guide

HIK VISION

HIK VISION DS-PK1-LRT-HWE quick start guide

Paradox K35 quick start

Paradox

Paradox K35 quick start

Onq IS-0369 REV. D Instruction/installation sheet

Onq

Onq IS-0369 REV. D Instruction/installation sheet

Paradox Paradox Digiplex DGP-610 user manual

Paradox

Paradox Paradox Digiplex DGP-610 user manual

Contro l4 KPE-10B1 Specifications

Contro l4

Contro l4 KPE-10B1 Specifications

XPR Access DINPAD-M manual

XPR Access

XPR Access DINPAD-M manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.