Likorall • 3EN200405 Rev. 8 8 www.liko.com
Material: Anodized aluminum
Emergency
lowering: Electrical and mechanical (not R2R)
Intermittent Int. Op 10/90, active operation
operation: max 6 min. Out of a time of 100,
active must be less than 10, however not more
than 6 min.
IP-class 43
This device is built for indoor operation.
Type B according to the degree of protection
against electric shock.
Class II equipment.
Before lifting always make certain that:
• the sling loops are correctly attached to the hooks
on the sling bar. This should be checked when
beginning to lift the patient - when the sling straps
are taut, but the patient is still seated.
Likorall is classied as a medical technical product
Class I. Likorall meet the requirements according to
SS-EN 60601-1, SS-EN 60601-1-2, and SS-EN ISO
10535.
Maximum Load 240/240 r2r: 180 kg (400 lbs)
Maximum Load 242/242 r2r: 200 kg (440 lbs)
Safety Instructions.............................................................................................. 2
Technical Specications .................................................................................... 2
Product Description ............................................................................................ 3
Assembling......................................................................................................... 3
Charging the battery .......................................................................................... 3
User's Guide....................................................................................................... 4
Operating Likorall........................................................................................................ 4
Changing Sling bars .................................................................................................. 4
Connecting Sling bars ................................................................................................ 4
Automatic emergency lowering................................................................................... 4
Mechanical emergency lowering ............................................................................... 4
Resetting the lifting height ......................................................................................... 4
Emergency lowering R2R ........................................................................................... 4
Safety cutoff ............................................................................................................... 4
Emergency stop ......................................................................................................... 5
Room to room transfers with R2R ....................................................................... 5
Recommended Slings and Accessories for Likorall............................................ 6
Troubleshooting.................................................................................................. 7
Care and Maintenance ....................................................................................... 8
Safety Instructions
Table of Contents
Before using make certain that:
•the lift is assembled as the instructions says.
•the safety split pin or nut is securely fastened in the
bolt that holds the sling bar or other accessories.
•all manuals for both lift and accessories have been
carefully studied and fully understood.
•persons using the equipment have received
appropriate instructions and training.
•all lift components, material, and seams are intact
and show no signs of damage or wear.
•the appropriate lifting accessory regarding type,
size, material and design in proportion to the
patient is used.
•the patient is positioned rmly and securely so that
no part of the body can be injured.
•the lift-strap is not twisted or worn, and that it
moves easily into the power unit.
Technical Specications
Lifting Capacity: 180 kg (240/240 R2R)
200 kg (242/242 R2R)
Batteries: Two 12 V 2,6 Ah valveregulated
lead-acidbatteries. New batteries are supplied
by the manufacturer.
Battery charger: 100-240 VAC 40-60 Hz max 0,6 A
Lifting speed: 5 cm/s
Lifting range: 210 cm (adjustable height)
Electrical data: 24 V 10 A/12 A
Dimensions motor: 250x125x300 mm. WxHxL.
Technical Data
Likorall 240, 242
Likorall 200
2Liko • www.liko.com
Material: Anodized aluminum
Emergency
lowering: Electrical and mechanical (not R2R)
Intermittent Int. Op 10/90, active operation
operation: max 6 min. Out of a time of 100,
active must be less than 10, however not more
than 6 min.
IP-class 43
This device is built for indoor operation.
Type B according to the degree of protection
against electric shock.
Class II equipment.
Before lifting always make certain that:
• the sling loops are correctly attached to the hooks
on the sling bar. This should be checked when
beginning to lift the patient - when the sling straps
are taut, but the patient is still seated.
Likorall is classied as a medical technical product
Class I. Likorall meet the requirements according to
SS-EN 60601-1, SS-EN 60601-1-2, and SS-EN ISO
10535.
Maximum Load 240/240 r2r: 180 kg (400 lbs)
Maximum Load 242/242 r2r: 200 kg (440 lbs)
Safety Instructions.............................................................................................. 2
Technical Specications .................................................................................... 2
Product Description ............................................................................................ 3
Assembling......................................................................................................... 3
Charging the battery .......................................................................................... 3
User's Guide....................................................................................................... 4
Operating Likorall........................................................................................................ 4
Changing Sling bars .................................................................................................. 4
Connecting Sling bars ................................................................................................ 4
Automatic emergency lowering................................................................................... 4
Mechanical emergency lowering ............................................................................... 4
Resetting the lifting height ......................................................................................... 4
Emergency lowering R2R ........................................................................................... 4
Safety cutoff ............................................................................................................... 4
Emergency stop ......................................................................................................... 5
Room to room transfers with R2R ....................................................................... 5
Recommended Slings and Accessories for Likorall............................................ 6
Troubleshooting.................................................................................................. 7
Care and Maintenance ....................................................................................... 8
Safety Instructions
Table of Contents
Before using make certain that:
•the lift is assembled as the instructions says.
•the safety split pin or nut is securely fastened in the
bolt that holds the sling bar or other accessories.
•all manuals for both lift and accessories have been
carefully studied and fully understood.
•persons using the equipment have received
appropriate instructions and training.
•all lift components, material, and seams are intact
and show no signs of damage or wear.
•the appropriate lifting accessory regarding type,
size, material and design in proportion to the
patient is used.
•the patient is positioned rmly and securely so that
no part of the body can be injured.
•the lift-strap is not twisted or worn, and that it
moves easily into the power unit.
Technical Specications
Lifting Capacity: 180 kg (240/240 R2R)
200 kg (242/242 R2R)
Batteries: Two 12 V 2,6 Ah valveregulated
lead-acidbatteries. New batteries are supplied
by the manufacturer.
Battery charger: 100-240 VAC 40-60 Hz max 0,6 A
Lifting speed: 5 cm/s
Lifting range: 210 cm (adjustable height)
Electrical data: 24 V 10 A/12 A
Dimensions motor: 250x125x300 mm. WxHxL.
3www.liko.com
Likorall 200 • 7EN120114-04
Technical Data
Maximum load: 200 kg (440 Ibs.)
Batteries: 2 x 12 V 2,4 Ah. Valve-regulated
lead-acid gel-type batteries.
New batteries are provided by
the supplier.
Battery charger: CH01 FW7218M/24; 100-240 V
AC, 50-60 Hz, max 500 mA
Lifting speed: 50 mm/s (2 inch./s)
Lifting interval: 2050 mm (80.7 inch.)
Electrical data: 24 V, 12 A
Lift unit
dimensions:
340x250x165 mm (LxWxH)
(13.4x9.8x6.5 inch. ,LxWxH)
Lift unit weight: 12.5 kg (27.5 lbs.)
Emergency
lowering device: Electrical
Likorall is equipped with a SFS (Single Fault Safety) safety drum. This patented safety design provides protection
against uncontrolled lowering. The lift strap has a tenfold safety.
Intermittent power:
Protection class
lift motor:
Sound level:
Protection class
hand control:
Operating forces
hand control:
Int. Op 10/90, active operation
max 0.5 min.
IP 33
51 dB
IP 54
3 N
Cable length
hand control:
870 mm (34 inch.)
Intended for indoor use.
Type B, in accordance with the electrical shock
protection class.
Denitions
1. Hand control with spring clamp
2. Emergency lowering device (electric)
3. Emergency stop string
4. Emergency stop
5. End cover
6. Charge indicator
7. Lift unit
8. SSP Limit Switch
9. Lift strap
10. Q-link (quick fastener)
11. Quick-release hook
12. Sling bar
13. Latches
3
6
1
8
5
2
7
10
9
11
13
12
4