16 Product description
Large Systems can also support remote subscribers. To do this, these
systems can be configured in a distributed system, using Remote IPE
modules or small cabinets. Fiber-optic links are used to connect the
Remote IPE modules and small cabinets to the PBXs.
In a distributed system, subscriber connections are the same at local
IPE modules as they are at Remote IPE modules or small cabinets.
Furthermore, because Remote IPE equipment uses common and network
equipment from the local system, subscriber functions and features are
the same at local and remote sites.
This document focuses on the system and Remote IPE equipment
specifically designed to provide fiber-optic links between network functions
in the local system and peripheral controller functions in the Remote IPE.
Physical architecture
To configure a system with Fiber Remote IPE, install a floor-standing
column or wall-mounted cabinet at a remote site and connect it using
fiber-optic links to an existing local system.
System equipment specifically designed to support the fiber-optics
interface is as follows:
•an NT1P61 Fiber Superloop Network card, which is housed in a local
system network card slot
•an NT1P62 Fiber Peripheral Controller card, which is housed in the
Remote IPE module or cabinet
•NT1P63 Electro-optical interface packlets, installed onto the Fiber
Superloop Network card and the Fiber Peripheral Controller card to
provide a fiber-optic link between the local system and Remote IPE
•an optional NT1P63 Electro-optical interface packlet at each site to
provide a redundant fiber-optic link
•an NT1P70 wall-mounted cabinet for the remote site
•NT1P75AA fiber-optic patchcords, one for each Electro-optical packlet
•NT1P79AA fiber-optic cable between the fiber management frame and
the Fiber Peripheral Controller in the wall-mounted cabinet and the
floor-standing column
•NT1P76AA cable connecting the Fiber Superloop Network card to the
I/O panel and providing Serial Data Interface (SDI) and system monitor
ports
•NT1P78AA cable connecting the Fiber Peripheral Controller card to the
I/O panel and providing TTY and system monitor ports
Nortel Communication Server 1000
Fiber Remote IPE Fundamentals
NN43021-554 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.