Olympus U-CBS User manual

Notes
This instruction manual is for the coded function system.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use
of this product, we recommend that you study this manual thoroughly before operating this
product, and always keep this manual at hand when operating this product.
Retain this instruction manual in an easily accessible place near the work desk for future
reference.
For details of products included in the configuration of this system, see page 4.
Instructions
Coded function system
Optical Microscope Accessory

In accordance with European Directive on Waste Electrical and Electronic Equipment, this
symbol indicates that the product must not be disposed of as unsorted municipal waste, but
should be collected separately.
Refer to your local Olympus distributor in EU for return and/or collection systems available in
your country.
This product is applied with the requirements of standard IEC/EN61326-1 concerning
electromagnetic compatibility.
- Immunity Applied to industrial and basic environment requirements.
For Korea only
이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서
가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다.

IMPORTANT -Be sure to read this section for safe use of the equipment.-................. 1
1 Nomenclature of each part............................................................................................................ 3
2 System diagram....................................................................................................................................... 4
3 Layout of the cables............................................................................................................................. 6
1Combining with the microscope frame (BX53F2) and U-IFRES..........................................................7
2Combining with the microscope frame (BX43F) and U-IFRES.............................................................8
3Combining with the microscope frame (BX43F)...............................................................................................9
4 Information readout / External transmission ...............................................................10
5 Specifications...........................................................................................................................................12
Contents

1
Coded function system
IMPORTANT -Be sure to read this section for safe use of the equipment.-
This system enables to read out the information from the coded illuminator and the coded revolving nosepiece and to
transmit the information externally.
Safety precautions
The following symbols are placed on this product.
Study the meaning of the symbols and always use the product in the safest possible manner.
Symbol Meaning
Indicates a non-specific general hazard. Follow the description given after this symbol or
in the instruction manual.
Indicates that the main switch is ON.
Indicates that the main switch is OFF.
Safety symbols
·Before connecting the cables, be sure to set the POWER switch of the control box for coded function
(U-CBS) to OFF (out position).
·For safety, always use the provided AC adapter only.
·Keep the cables away from the lamp housings (halogen bulb, etc.) that become hot and the surroundings.
Otherwise, the cables may melt and cause an electric shock hazard.
·Never apply an excess force to cables, such as to stretch cables. Otherwise, they may be damaged.

Coded function system
2
·This product is a precision instrument. Handle it with care and connect cables gently to avoid
subjecting it to sudden or severe impact. Also, this product is not waterproof.
·Do not use the product in areas where it may be subjected to direct sunlight, high temperature and/or
humidity, dust or vibrations.
(For conditions of operating environments, see “5 Specifications“ on page 12.)
·Never connect or disconnect the cable while the POWER switch of the control box is set to ON
(depressed position). Otherwise, malfunction may result.
·Never disassemble any part of the product. Otherwise, failure may result.
·Before disposing of this product, be sure to follow the regulations and rules of your local government.
Contact Olympus for any questions.
CAUTION
2Handling Precautions
1Cautions
If the product is used in a manner not specified by this manual, the safety of the user may be imperiled. In addition, the
product may also be damaged. Always use the product according to this instruction manual.
The following symbols are used in this instruction manual.
CAUTION
: Indicates a potentially hazardous situation which, if not avoided, may result in
damage to the equipment or other property.
TIP
: Indicates the useful knowledge or information for use.

3
Coded function system
1Nomenclature of each part
Control box for coded function
U-CBS
Microscope frame hanger (top)
Connector for hand switch
For external EXPOSE button of
microscope digital camera
Connector for BX3-CBM
Connector for AC adapter
RS-232C connector
Connector for coded revolving nosepiece
Connector for coded illuminator
POWER switch
ON: Depressed position
OFF: Out position
Microscope frame hanger (bottom)

Coded function system
4
2 System diagram
Coded illuminator
Control box for coded functionNote 3)
U-CBS
Microscope
frame
·The connectors of U-CBS are equipped with dust covers. Remove the dust covers only from the
connectors you want to connect cables.
·Be sure to connect only the units specified by Olympus to the connecters of U-CBS.
If a non-specified unit is connected, the performance of the entire system cannot be guaranteed.
·Before connecting the cables, be sure to set the POWER switch of U-CBS to OFF (out position).
Insert the cables securely to connectors paying attention to their shapes. If the connector is provided
with clamping screws, be sure to tighten them.
·If you insert a non-specified connector into the connector of U-CBS, the connector may be damaged.
CAUTION
· PC
· Microscope digital cameraNote 4)
Cable for coded illuminator Note 2)
RS-232C cableNote 1)
AC adapter
Cable for interface for coded nosepieceNote 2)
Interface for coded nosepiece
U-IFRES
Hand switch
U-HSEXP
Control box
BX3-CBM
Coded revolving
nosepiece
Interface for coded nosepiece
Interface for coded nosepiece
U-IFRES
U-IFRES
Cable for revolving
nosepiece
Hand switch
U-HSEXP
Control box
BX3-CBM
Control box
BX3-CBM
AC adapter
Interface cable
CBSIFCBL200

5
Coded function system
Note 1)
RS-232C cable specifications
D-sub 9-pin (F) D-sub 9-pin (F)
a
d
c
Note 2)
Align the mark aon the connector of the coded illuminator with
the mark aof U-CBS and attach the coded illuminator. When
attaching U-IFRES or the coded revolving nosepiece, align marks
bin the same manner.
Note 3)
Hang U-CBS con the hangers don the back side of the
microscope frame.
Note 4)
When connecting the microscope digital camera to U-CBS to use
U-CBS, the order to turn ON the power is: 1POWER switch of
U-CBS and 2Switch of the microscope digital camera. If the
switches are set to ON in the different order, the microscope digital
camera cannot recognize U-CBS.
Also, if the connector of the coded revolving nosepiece are not
connected to U-CBS, U-CBS does not recognize the coded
revolving nosepiece. So be careful.
b

Coded function system
6
3Layout of the cables
The cables of units can be laid out easily by attaching the cable holders on the back side of the microscope frame.
The cable holders are provided with following units.
· Control box for coded function (U-CBS): 6 pieces
· Coded revolving nosepiece: 2 pieces
On page 7 and after, the positions to attach cable holders and the cable layout are described for each microscope frame.
· The number of cable holders to be used differs depending on the units combined with the microscope frame.
· If the cable holder positions are significantly deviated, the cable may not reach the connector. Attach the cable
holders while making sure that the cable reaches the connector.
· Make sure that cable holders are not deflected and close the cable holders.
TIP

7
Coded function system
About 69 mm
* :In case of laid out the cable for hand switch on the left side as shown above picture
**:In case of laid out the cable for hand switch on the right side as shown above picture
For procedures to attach the hand switch to microscope frame, see page 11.
TIP
Hand switch**
Cable holder**
Velcro tape
RS-232C cable
Coded illuminator
(provided with hand switch)
About 78 mm
AC adapter
Cable holder*
Hand switch*
About 85 mm
Cable holder*
Align with the upper left
corner of the label.
Coded revolving nosepiece
U-IFRES
1Combining with the microscope frame (BX53F2) and U-IFRES
Align with the height of
the edge between the
back side and under
side on the microscope
frame.
back side and under
side on the microscope
frame.

Coded function system
8
2Combining with the microscope frame (BX43F) and U-IFRES
* :In case of laid out the cable for hand switch on the left side as shown above picture
**:In case of laid out the cable for hand switch on the right side as shown above picture
For procedures to attach the hand switch to microscope frame, see page 11.
TIP
Hand switch**
Cable holder**
Velcro tape
RS-232C cable
Coded illuminator
(provided with hand switch)
About 78 mm
AC adapter
Cable holder*
Hand switch*
About 63 mm
Cable holder*
Align with the upper left
corner of the label.
Coded revolving nosepiece
U-IFRES
Align with the upper right
corner of the label.

POWER
9
Coded function system
3Combining with the microscope frame (BX43F)
* :In case of laid out the cable for hand switch on the left side as shown above picture
**:In case of laid out the cable for hand switch on the right side as shown above picture
For procedures to attach the hand switch to microscope frame, see page 11.
TIP
Hand switch**
Cable holder**
Velcro tape
RS-232C cable
Coded illuminator
(provided with hand switch)
About 78 mm
AC adapter
Cable holder*
Hand switch*
About 63 mm
Cable holder*
Align with the upper left
corner of the label.
Coded revolving nosepiece
Align with the upper right
corner of the label.

Coded function system
10
This system configuration enables to acquire the information of following units.
· Information of the hole position (objective position) of the revolving nosepiece
· Information of the mirror unit position of the coded illuminator
The acquired information is transmitted to PC or the microscope digital camera through the RS-232C cable to enable
following functions.
· Implement following functions using PC by interlocking to the hole positions of the revolving nosepiece or mirror
unit positions.
(Increase of the speed of exposure time control, addition of the magnification information to acquired images,
automatic scale change according to objective, etc.)
· Enable to operate the EXPOSE button of the microscope digital camera near the coarse focusing knob of the
microscope frame by using the hand switch.
(For procedures to attach the hand switch, see page 11.)
Transmitting the acquired information to the control box (BX3-CBM) enables following functions.
· Enable to change the optical elements of the motorized condenser when objective is selected by rotating the
coded revolving nosepiece.
(The motorized condenser and control box (BX3-CBM) are required.)
4Information readout / External transmission

11
Coded function system
Attach the attaching plate bto the magnet on the bottom of the
hand switch a.
Do not remove the sheet on the adhesive surface of the attaching
plate until the attaching position is decided.
Decide the attaching position ceasy to operate the hand switch (
part) near the right or left coarse adjustment knob.
Be careful if the hand switch is attached too close to the
coarse focusing knob, when the pre-focusing lever dis
rotated, the hand switch may contact the pre-focusing lever.
Clean the attaching position with a soft cloth, remove the sheet on the
adhesive surface of the attaching plate and attach the hand switch
firmly to the microscope frame.
·Since the hand switch is provided with the magnet, do not
let objects that are affected by magnetism come close to
the hand switch.
·Be careful, if the connector of the coded revolving
nosepiece is not connected to U-CBS, the hand switch
does not function.
If the cable for the hand switch disturbs your operation, bundle
the cable with the Velcro tape provided with the hand switch.
1
TIP
2
TIP
3
CAUTION
TIP
c
a
b
3
d
Attaching the hand switch
The hand switch is provided with the magnet. Adhering the attaching plate made of iron on the microscope frame allows
you to secure the hand switch to the attaching plate. (Two attaching plates are provided with the hand switch and one of
them is for use as a spare.)

Coded function system
12
Item Specifications
Control box for coded function
U-CBS
Dimension 37.8 (W) x 30.6 (D) x 163 (H) mm
Weight 0.5 kg (including AC adapter 0.17 kg)
Rating 5 V / 0.5 A
Hand switch
U-HSEXP
Dimension Body: Ø25.4 x 35.5 (H) mm
Attaching plate: Ø32 x 1 (H) mm
Weight 0.065 kg
AC adapter Input 100-240 V 50-60 Hz 0.4 A
Output 5 V 2.5 A
Operating environment · Indoor use
· Altitude: Max. 2,000 meters
· Ambient temperature: 5 to 40 °C (41 to 104 °F)
· Maximum relative humidity: 80% for temperatures up to 31 °C (88 °F) (without
condensation)
In case of over 31 °C (88 °F), the relative humidity is decreased linearly through 70% at
34 °C (93 °F), 60% at 37 °C (99 °F), and to 50% at 40 °C (104 °F).
· Supply voltage fluctuations: Not to exceed ±10% of the normal voltage.
· Pollution degree 2 (in accordance with IEC60664-1)
· Installation/Overvoltage category: II (in accordance with IEC60664-1)
5Specifications

AX9442 01
Distributed by
Manufactured by
Shinjuku Monolith, 2-3-1 Nishi-Shinjuku, Shinjuku-ku, Tokyo 163-0914, Japan
www.olympus-global.com
Table of contents
Other Olympus Microscope manuals

Olympus
Olympus BX61WI User manual

Olympus
Olympus IX73 User manual

Olympus
Olympus FH User manual

Olympus
Olympus Pom User manual

Olympus
Olympus VMF Operating instructions

Olympus
Olympus AH3 Operating instructions

Olympus
Olympus SZ-III User manual

Olympus
Olympus BX51M User manual

Olympus
Olympus SZX10 User manual

Olympus
Olympus BX3M-CB User manual

Olympus
Olympus CHS User manual

Olympus
Olympus FV5-LD405 User manual

Olympus
Olympus VS110 Fluorescence User manual

Olympus
Olympus VS120 User manual

Olympus
Olympus SZ61 User manual

Olympus
Olympus CX43 User manual

Olympus
Olympus CHBS User manual

Olympus
Olympus CH Series Operating instructions

Olympus
Olympus BX63 User manual

Olympus
Olympus CX33 User manual