Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Q I G
DIP Switch Setting
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2 1A@24V
V2- V2+ V1- V1+
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer
to the following tablet for LED indication.
Specifications
P1 Green On DC power 1 activated
P2 Green On DC power 2 activated
Fault Amber On Power failure
10/100Base-T(X) Ethernet ports
LNK/ACT Green On Port is linked
Duplex Amber
On Port link up for full duplex
Off Port link up for half duplex
For pin assignments for different types of cables, please refer to the following
tables.
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
Version 2.2
DIP-2
OFF
OFF
ON
DIP-1
Power failure relay alarm disabled
PWR-1 failure, relay alarm enabled
PWR-2 failure, relay alarm enabled
OFF
ON
OFF
Description
ON PWR-1 or PWR-2 failure,
relay alarm enabled
ON
10/100Base-T(X) RJ-45
Pin Number Assignment
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
Note: “+” and “-” signs represent the polarity of the wires
that make up each wire pair.
ORing Switch Model
Physical Ports
Technology
Ethernet Stan d a rds
LED Indicators
Green: Power LED x2Power indicator
10/100Base-T(X) Port in RJ45
Auto MDI/MDIX
IEEE 802.3 for 10Base-T,
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
Processing St o r e-and-Forward
Environmental
-40 to 85 C (-40 to 185 F)
o o
Storage Tempera ture
Operating Temperature
5% to 95% Non-con d ensingOperating Humidity
Regulatory approvals
CE EMC (EN 55024, E N 5 5032), FCC Part 15 BEMC
EN 55024 (IEC/E N 6 1 000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (R S : 3 V)
IEC/EN 61000- 4 - 4 (EF T Power 0.5KV, Signal 0.5KV),
IEC/EN 61000- 4 - 5 (Surge: Power 0.5KV, Signal 1KV ) , IEC/EN 61000-4-6 (CS: 3V),
IEC/EN 61000- 4 - 8(PFMF), IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2- 2 7Shock
IEC60068-2- 3 2
IEC60068-2- 6Vibration
Free Fall
MTBF
1,555,711h r s
-40 to 75 C (-40 to 167 F)
o o
Amber: Indica t e PWR1 or PWR2 failure
Fault indicator
Fault contact
Relay Relay output to c a rry capacity of 1A at 24 VDC
Power
Redundant Input power
Power consumption(Typ. ) <2Watts, 0.13A-0.04A
Overlo a d current protection
Reverse polarity protection
Present
Present
Physical Characteristic
Enclosure IP-3 0 M etal
Dimension (W x D x H )
Weight (g) 382 g
Dual 12~48VD C o n 6-pin terminal block
26.1(W)x94. 9 ( D)x144.3(H) mm (1.03x3.74x5.68inch.)
10/100Base-T (X) RJ45 Port
Indicator
Upper LED for Li n k/Act indicator: Green for Link/Act
Lower LED for du p l ex indicator, Amber for full duplex, off for half dupl e x
EN60950-1(LVD)Safety
IES-1050A
5
MAC Table 1K
Packet buffer 1Mbits
Warranty
5 years
Switc h P r operties
Switc h i ng latency: 7 us
Switc h i ng bandwidth: 1Gbps
Throughput (p a c ket per second): 0.744Mpps@64Bytes packet
Hardwa r e Version V2.0
EN 55032, CISP R 3 2, EN 61000-3-2, EN 61000-3-3, FCC Pa r t 15 B class AEMI
IES-1050A Industrial Unmanaged Switch
S W I T C H
I N D U S T R I A L
IES-1050A