ORiNG IES-1050A User manual

PWR- 1PWR- 2
V2+ V2 - V1+ V1 -
G
1A@2 4V DC1 2-48 V
P1 P2 Fau lt
IES-1050A
3
4
1
2
5
Quick Installation Guide
Version 2.2
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient: If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow: Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Safety & Warnings
Dimension
Panel Layouts
1. PWR indicators
2. Faulty relay indicator
3. LAN port link/act indicator
4. LAN port duplex indicator
5. LAN ports
Package Contents
Front View
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
Installation
Step 1: Slant the switch and screw the Din-rail kit onto the back of the switch, right in
the middle of the back panel.
Step 2: Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch
clicks into the rail firmly.
DIN-rail Installation
Step 1: Screw the wall-mount kit onto the rear panel of the switch. A total of six
screws are required, as shown below.
Step 2: Use the switch, with wall mount plates attached, as a guide to mark the
correct locations of the four screws.
Step 3: Insert a screw head through the large parts of the keyhole-shaped apertures,
and then slide the switch downwards. Tighten the screws for added stability.
Wall-mounting
Q I G 1907-200-E1050AXXX2-FX012
Mechanical Loading: Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of the equipment to
the supply circuit and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings
should be used when addressing this concern.
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses
CAT 3,4,5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable
specifications.
Cable Types and Specifications:
Cable
Type
Max. Length
Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
Unit =mm (Tolerance ±0.5mm)
Features
Contents
Wall-mount Kit
DIN-rail Kit
IES-1050A
Pictures Number
X 2
X 1
QIG X 1
X 1
6-pin terminal block X 1
3
5
4
Rear View
1
1. Din-rail screw holes
Top Panel
1. Wall-mount screw holes
2. Terminal blocks: PWR1, PWR2
, Relay
3. DIP Switch
4. Ground wire.
2 3
4
1
1
is unmanaged Ethernet Switch with 5x10/100Base-T(X) ports and extendedIES-1050A
operating temperature range from -40 C to 75 C for the harsh environments. The
o o
enclosure designed with compact size and a robust housing; it can help you to easily
installed.
Support 5 ports 10/100Base-T(X)
Support auto-negotiation and auto-MDI/MDI-X
Support store and forward transmission
Support flow control
Provide Relay output
Compact size for easily installation
Rigid IP-30 housing design
DIN-Rail and wall mounting enable
IES-1050A
IES-1050A
94.9
68.15
8.0
14.0 6.05
25.0
50.0
25.5
8.5
25.6
24.3
Ø5.9
Ø3.0
26.1
144.3
12.3
13.1
24.3
Ø4.0
12
Industrial Unmanaged Switch
S W I T C H
I N D U S T R I A L
P1 P2 Faul t
IES-1050A
3
4
1
2
5
P1 P2 Faul t
IES-1050A
3
4
1
2
5
Q I G Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Q I G
DIP Switch Setting
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
STEP 1: Insert the negative/positive wires into the V-/V+ terminals,
respectively.
STEP 2: To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
PWR-1PWR-2 1A@24V
V2- V2+ V1- V1+
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an close circuit when a
user-configured event is triggered. If a user-configured event does not occur, the fault
circuit remains opened.
Relay contact
Grounding and wire routing help limit the effects of noise due to electromagnetic
interference (EMI). Run the ground connection from the ground screws to the grounding
surface prior to connecting devices.
Grounding
Configurations
After installing the switch, the green power LED should turn on. Please refer
to the following tablet for LED indication.
Specifications
LED
Color
Status
Description
P1 Green On DC power 1 activated
P2 Green On DC power 2 activated
Fault Amber On Power failure
10/100Base-T(X) Ethernet ports
LNK/ACT Green On Port is linked
Duplex Amber
On Port link up for full duplex
Off Port link up for half duplex
For pin assignments for different types of cables, please refer to the following
tables.
ORing Industrial Networking Corp.
Copyright© 2010 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oringnet.com
E-mail: support@oringnet.com
Version 2.2
DIP-2
OFF
OFF
ON
DIP-1
Power failure relay alarm disabled
PWR-1 failure, relay alarm enabled
PWR-2 failure, relay alarm enabled
OFF
ON
OFF
Description
ON PWR-1 or PWR-2 failure,
relay alarm enabled
ON
10/100Base-T(X) RJ-45
Pin Number Assignment
1 TD+
2 TD-
3 RD+
4 Not used
5 Not used
6 RD-
7 Not used
8 Not used
Note: “+” and “-” signs represent the polarity of the wires
that make up each wire pair.
ORing Switch Model
Physical Ports
Technology
Ethernet Stan d a rds
LED Indicators
Green: Power LED x2Power indicator
10/100Base-T(X) Port in RJ45
Auto MDI/MDIX
IEEE 802.3 for 10Base-T,
IEEE 802.3u for 100Base-TX
IEEE 802.3x for Flow control
Processing St o r e-and-Forward
Environmental
-40 to 85 C (-40 to 185 F)
o o
Storage Tempera ture
Operating Temperature
5% to 95% Non-con d ensingOperating Humidity
Regulatory approvals
CE EMC (EN 55024, E N 5 5032), FCC Part 15 BEMC
EN 55024 (IEC/E N 6 1 000-4-2 (ESD: Contact 4KV, Air 8KV), IEC/EN 61000-4-3 (R S : 3 V)
IEC/EN 61000- 4 - 4 (EF T Power 0.5KV, Signal 0.5KV),
IEC/EN 61000- 4 - 5 (Surge: Power 0.5KV, Signal 1KV ) , IEC/EN 61000-4-6 (CS: 3V),
IEC/EN 61000- 4 - 8(PFMF), IEC/EN 61000-4-11 (DIP))
EMS
IEC60068-2- 2 7Shock
IEC60068-2- 3 2
IEC60068-2- 6Vibration
Free Fall
MTBF
1,555,711h r s
-40 to 75 C (-40 to 167 F)
o o
Amber: Indica t e PWR1 or PWR2 failure
Fault indicator
Fault contact
Relay Relay output to c a rry capacity of 1A at 24 VDC
Power
Redundant Input power
Power consumption(Typ. ) <2Watts, 0.13A-0.04A
Overlo a d current protection
Reverse polarity protection
Present
Present
Physical Characteristic
Enclosure IP-3 0 M etal
Dimension (W x D x H )
Weight (g) 382 g
Dual 12~48VD C o n 6-pin terminal block
26.1(W)x94. 9 ( D)x144.3(H) mm (1.03x3.74x5.68inch.)
10/100Base-T (X) RJ45 Port
Indicator
Upper LED for Li n k/Act indicator: Green for Link/Act
Lower LED for du p l ex indicator, Amber for full duplex, off for half dupl e x
EN60950-1(LVD)Safety
IES-1050A
5
MAC Table 1K
Packet buffer 1Mbits
Warranty
5 years
Switc h P r operties
Switc h i ng latency: 7 us
Switc h i ng bandwidth: 1Gbps
Throughput (p a c ket per second): 0.744Mpps@64Bytes packet
Hardwa r e Version V2.0
EN 55032, CISP R 3 2, EN 61000-3-2, EN 61000-3-3, FCC Pa r t 15 B class AEMI
IES-1050A Industrial Unmanaged Switch
S W I T C H
I N D U S T R I A L
IES-1050A

Other manuals for IES-1050A

1

Other ORiNG Switch manuals

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG TGPS-9164GT-M12X-BP2-24V User manual

ORiNG

ORiNG TGPS-9164GT-M12X-BP2-24V User manual

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG

ORiNG RGPS-R9244GP+-P Series User manual

ORiNG IDS-342GT User manual

ORiNG

ORiNG IDS-342GT User manual

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG IES-2050-M12 User manual

ORiNG

ORiNG IES-2050-M12 User manual

ORiNG Transporter Series User manual

ORiNG

ORiNG Transporter Series User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG IGPS-9084GP-LA User manual

ORiNG

ORiNG IGPS-9084GP-LA User manual

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG IPS-2042TX Series User manual

ORiNG

ORiNG IPS-2042TX Series User manual

ORiNG IGS-9848GPF User manual

ORiNG

ORiNG IGS-9848GPF User manual

ORiNG TGPS-9084GT-M12X-BP2-MV User manual

ORiNG

ORiNG TGPS-9084GT-M12X-BP2-MV User manual

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG IBS-102FX User manual

ORiNG

ORiNG IBS-102FX User manual

ORiNG IPS-1080-24V User manual

ORiNG

ORiNG IPS-1080-24V User manual

ORiNG IPS-1042FX-24V Series User manual

ORiNG

ORiNG IPS-1042FX-24V Series User manual

ORiNG IGS-9084GP User manual

ORiNG

ORiNG IGS-9084GP User manual

ORiNG IGS-9168GP series User manual

ORiNG

ORiNG IGS-9168GP series User manual

ORiNG IGPS-1041GTA User manual

ORiNG

ORiNG IGPS-1041GTA User manual

ORiNG Thunder Series User manual

ORiNG

ORiNG Thunder Series User manual

ORiNG IGPS-9042GP-24V User manual

ORiNG

ORiNG IGPS-9042GP-24V User manual

ORiNG TGS-1080-M12 Series User manual

ORiNG

ORiNG TGS-1080-M12 Series User manual

ORiNG IGS-9084GP-LA User manual

ORiNG

ORiNG IGS-9084GP-LA User manual

Popular Switch manuals by other brands

Lutron Electronics Vive HMS-0 manual

Lutron Electronics

Lutron Electronics Vive HMS-0 manual

Panasonic GA-ML4TWPoE++ installation guide

Panasonic

Panasonic GA-ML4TWPoE++ installation guide

H3C S5830V2 series Configuration guide

H3C

H3C S5830V2 series Configuration guide

Leonton BG5-0702-SFP Series user manual

Leonton

Leonton BG5-0702-SFP Series user manual

Digitus DS-12850 user manual

Digitus

Digitus DS-12850 user manual

BDI AES-402 Reference manual

BDI

BDI AES-402 Reference manual

iotty E2S PLUS manual

iotty

iotty E2S PLUS manual

Allen-Bradley 194R Series manual

Allen-Bradley

Allen-Bradley 194R Series manual

Weller WDH 10T operating instructions

Weller

Weller WDH 10T operating instructions

Dell PowerConnect 2708 Appendix

Dell

Dell PowerConnect 2708 Appendix

DirectConnect DC-S-24M user manual

DirectConnect

DirectConnect DC-S-24M user manual

Belden Hirschmann RS20 Series user manual

Belden

Belden Hirschmann RS20 Series user manual

H3C S5830V2 series MCE Command Reference

H3C

H3C S5830V2 series MCE Command Reference

Cabletron Systems MMAC-Plus 9H531-24 user guide

Cabletron Systems

Cabletron Systems MMAC-Plus 9H531-24 user guide

Cisco Business 250 Series Get to know

Cisco

Cisco Business 250 Series Get to know

Barksdale KD1 Series operating instructions

Barksdale

Barksdale KD1 Series operating instructions

Belkin OmniView F1DB102P2 user manual

Belkin

Belkin OmniView F1DB102P2 user manual

Cisco Nexus 3000 series Hardware installation guide

Cisco

Cisco Nexus 3000 series Hardware installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.