Reliable F156 Series Manual

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Model F1
Model F1FR
Intermediate Level
Sprinklers
Features
1. Upright and pendent installations.
2. Available as either a standard response Model F1
or quick response Model F1FR.
3. Temperature ratings of 135 °F (57 °C), 155 °F
(68 °C), 175 °F (79 °C), 200 °F (93 °C) and 286 °F
(141 °C) for Models F1 and F1FR; the Model
F1 is also available in additional rating of 360 °F
(182 °C).
4. 17/32” (20 mm) orifice with 3/4” NPT (R
3/4).
For Model F156/F1FR561/2” K 5.6 (80) Sprinkler Types refer to
Bulletin 031 for technical specifications and approvals.
Listings and Approvals
1. Listed by Underwriters Laboratories, Inc. (UL)
2. Listed by Underwriters’ Laboratories of Canada (ULC)
3. Certified by FM Approvals
4. NYC MEA No. 258-93-E
UL Listing Category
Sprinklers, Automatic and Open (VNIV)
Product Description
The Reliable Models F1 and F1FR Intermediate Level
Sprinklers include shields which protect the glass bulb from
water spray impingement caused by sprinklers located at a
higher elevation.
Typical applications are for storage racks which require multi–
level sprinklers and beneath open grid catwalks.
Application
Model F1 and F1FR Intermediate Level sprinklers are used
in fixed fire protection systems: Wet, Dry, Deluge or Preaction.
Care must be exercised that the orifice size, temperature
rating, deflector style and sprinkler type are in accordance with
the latest published standards of the National Fire Protection
Association or the Authority Having Jurisdiction.
Installation
Model F1 sprinklers are standard response sprinklers and
Model F1FR are quick response sprinklers. Both types are
intended for installation as specified in NFPA 13. Upright
sprinklers must be installed with the Model D Sprinkler Wrench
specifically designed by Reliable for use with these sprinklers
and pendent sprinklers must be installed with the Model GFR1
Sprinkler Wrench specifically designed by Reliable for use with
these sprinklers.
Model F1
Pendent Intermediate
Model F1
Upright Intermediate
Glass bulb sprinklers have orange covers to protect the bulb
during the installation process. REMOVE THIS PROTECTION
ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY
TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS
HAVE BEEN INSTALLED. RASCO wrenches are designed to
install sprinklers when covers are in place.
Maintenance
The Models F1 and F1FR Sprinklers should be inspected and
the sprinkler system maintained in accordance with NFPA 25.
Do not clean sprinklers with soap and water, ammonia or any
other cleaning fluid. Remove dust by using a soft brush or gentle
vacuuming. Remove any sprinkler which has been painted (other
than factory applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick replacement of
damaged or operated sprinklers. Prior to installation, sprinklers
should be maintained in the original cartons and packaging until
used to minimize the potential for damage to sprinklers that
would cause improper or non-operation.
Model F1FR
Upright Intermediate
Model F1FR
Pendent Intermediate
Multilingual document:
Select your language below
Bulletin 170 Rev I_Multilingual
Bulletin 170 Rev I_Multilingual
2
170FG01C
170FG02
Model F1FR Quick Response Upright and Pendent Intermediate Level Sprinklers
Installation Data:
Sprinkler
Type
Nominal
Orifice Thread Size K-Factor Sprinkler
Identification
Number (SIN)
Shield Part
Number
Sprinkler
Height Approvals
US Metric
Pendent 17/32” (20 mm) 3/4” NPT (R
3/4)8.00 115.30 R3612 88701412 2.3” 1, 2, 3, 4
Upright 17/32” (20 mm) 3/4” NPT (R
3/4)8.00 115.30 R7092 88701410 2.3” 1, 2, 3, 4
Model F1 Standard Response Upright and Pendent Intermediate Level Sprinklers
Installation Data:
Sprinkler
Type
Nominal
Orifice Thread Size K-Factor Sprinkler
Identification
Number (SIN)
Shield Part
Number
Sprinkler
Height Approvals
US Metric
Pendent 17/32” (20 mm) 3/4” NPT (R
3/4)8.00 115.30 R1712 88701412 2.3” 1, 2, 3, 4
Upright 17/32” (20 mm) 3/4” NPT (R
3/4)8.00 115.30 R7022 88701410 2.3” 1, 2, 3, 4
Models F1 and F1FR Upright Intermediate Level Sprinklers
Models F1 and F1FR Pendent Intermediate Level Sprinkler
3 1/4” DIA.
“O” RING
SEE TABLE FOR
SPRINKLER
HEIGHT
E-RING
RETAINER
CLIP
SHIELD
SPRINKLER ASSEMBLY
TO BE ASSEMBLED
AT INSTALLATION
MODEL F1
3/4” THREAD SHOWN
3 1/4” DIA.
SHIELD
SEE TABLE FOR
SPRINKLER
HEIGHT
MODEL F1FR 17/32” ORIFICE SHOWN
3
Temperature Ratings For F1FR:
Classification Sprinkler Temperature Bulb Color
°F °C
Ordinary 135 57 Orange
Ordinary 155 68 Red
Intermediate 175 79 Yellow
Intermediate 200 93 Green
High 286 141 Blue
Temperature Ratings For F1:
Classification Sprinkler Temperature Bulb Color
°F °C
Ordinary 135 57 Orange
Ordinary 155 68 Red
Intermediate 175 79 Yellow
Intermediate 200 93 Green
High 286 141 Blue
Extra High 360 182 Mauve
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Temperature Rating
5. Sprinkler Finish
Installation Wrenches
Upright — Model D Sprinkler Wrench
Pendent — Model GFR2 Sprinkler Wrench
Finishes(1)
Standard Finishes
Bronze
Special Application Finishes
Electroless Nickel PTFE(Teflon®)*(4)(5)
Bright Chrome
Chrome Dull
Polyester Coated
Lead Plated(2)(4)
Wax Coated(2)(3)(4)
Wax Over Lead(2)(3)(4)
(1) Other colors and finishes are available. Consult factory for details.
(2) Model F1 Standard Response only.
(3) 55 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C) and 286 °F (141 °C)
temperature ratings only.
(4) Only the sprinkler is wax coated, lead or Electroless Nickel PTFE (Teflon®)*
plated. The shield finish remains galvanized zinc.
(5) cULus listed Corrosion Resistant.
Note: Paint or any other coating applied over the factory finish
will void approvals and warranties.
Shields
Galvanized Zinc
*DuPont Registered Trademark
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588 Sales Offices
(800) 848-6051 Sales Fax
(914) 829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address
Manufactured by Recycled
Paper
Revision lines indicate updated or new data.
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years.
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
Reliable... For Complete Protection
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
• Deluge valves
• Detector check valves
• Check valves
• Electrical system
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gauges
• Identification signs
• Fire department connection
EG. Printed in U.S.A. 05/14 P/N 9999970034

Other manuals for F156 Series

8

This manual suits for next models

3

Other Reliable Irrigation System manuals

Reliable F1-300 User manual

Reliable

Reliable F1-300 User manual

Reliable F1FR56 User manual

Reliable

Reliable F1FR56 User manual

Reliable KFR56 Series User manual

Reliable

Reliable KFR56 Series User manual

Reliable DDX PrePaK Maintenance manual

Reliable

Reliable DDX PrePaK Maintenance manual

Reliable MBEC-14 Manual

Reliable

Reliable MBEC-14 Manual

Reliable F156 Series User manual

Reliable

Reliable F156 Series User manual

Reliable F1FR-SS Series Manual

Reliable

Reliable F1FR-SS Series Manual

Reliable F1 LO User manual

Reliable

Reliable F1 LO User manual

Reliable F1FR – 300 User manual

Reliable

Reliable F1FR – 300 User manual

Reliable F156-300 Series Manual

Reliable

Reliable F156-300 Series Manual

Reliable G6-80 Manual

Reliable

Reliable G6-80 Manual

Reliable JL-14 Manual

Reliable

Reliable JL-14 Manual

Reliable F1FR80 Series User manual

Reliable

Reliable F1FR80 Series User manual

Reliable F3-80 Series Manual

Reliable

Reliable F3-80 Series Manual

Reliable F3QR56 User manual

Reliable

Reliable F3QR56 User manual

Reliable G6-56 User manual

Reliable

Reliable G6-56 User manual

Reliable RFC43 User manual

Reliable

Reliable RFC43 User manual

Reliable F1-42 Series Manual

Reliable

Reliable F1-42 Series Manual

Reliable GL 112 User manual

Reliable

Reliable GL 112 User manual

Reliable F3QR80 Series User manual

Reliable

Reliable F3QR80 Series User manual

Reliable F3-80 Series User manual

Reliable

Reliable F3-80 Series User manual

Reliable DDX PrePaK D Maintenance manual

Reliable

Reliable DDX PrePaK D Maintenance manual

Reliable F1-28 Series User manual

Reliable

Reliable F1-28 Series User manual

Reliable G Series Manual

Reliable

Reliable G Series Manual

Popular Irrigation System manuals by other brands

Viking FREEDOM VK479 Technical data

Viking

Viking FREEDOM VK479 Technical data

Autopot 80Pot system Set-up guidelines

Autopot

Autopot 80Pot system Set-up guidelines

Victaulic VicFlex V32 Assembly instructions

Victaulic

Victaulic VicFlex V32 Assembly instructions

Tyco TY-QRF-5.6 quick start guide

Tyco

Tyco TY-QRF-5.6 quick start guide

Viking VK482 quick start guide

Viking

Viking VK482 quick start guide

Johnson Controls tyco TY-B Series manual

Johnson Controls

Johnson Controls tyco TY-B Series manual

Gardeners Snip-n-Spray manual

Gardeners

Gardeners Snip-n-Spray manual

K-Rain MiniPro Setting instructions

K-Rain

K-Rain MiniPro Setting instructions

AQUAJOE SJI-OMS16 user manual

AQUAJOE

AQUAJOE SJI-OMS16 user manual

K-Rain RPS50 Setting instructions

K-Rain

K-Rain RPS50 Setting instructions

Tyco TY-B Series quick start guide

Tyco

Tyco TY-B Series quick start guide

Blumfeldt 10031357 manual

Blumfeldt

Blumfeldt 10031357 manual

Tyco D4a manual

Tyco

Tyco D4a manual

Tyco SW-20 manual

Tyco

Tyco SW-20 manual

Autopot 80Pot system Set-up guidelines

Autopot

Autopot 80Pot system Set-up guidelines

Rain S-Dial installation manual

Rain

Rain S-Dial installation manual

Viking 10284 Technical data

Viking

Viking 10284 Technical data

Orbit 27752 instruction manual

Orbit

Orbit 27752 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.